Laparoscopic radiofrequency ablation of unresectable hepatic malignancies - A phase 2 trial

被引:0
作者
Chung, MH [1 ]
Wood, TF [1 ]
Tsioulias, GJ [1 ]
Rose, DM [1 ]
Bilchik, AJ [1 ]
机构
[1] St Johns Hlth Ctr, John Wayne Canc Inst, Santa Monica, CA 90404 USA
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 2001年 / 15卷 / 09期
关键词
hepatic; laparoscopic; radiofrequency ablation; unresectable;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Radiofrequency ablation (RFA) of hepatic malignancies has been performed successfully via a percutaneous route or at laparotomy. We analyzed the efficacy and utility of laparoscopic intraoperative ultrasound and RFA in patients with unresectable hepatic malignancies. Methods: Between November 1997 and November 1999, 27 patients with unresectable hepatic malignancies and no evidence of extrahepatic disease were entered in a phase 2 trial of laparoscopic intraoperative ultrasound and RFA. Real-time ultrasonography was used to guide RFA, and lesions were ablated at a temperature of 100 degreesC for 10 min. Overlapping ablations were performed for larger lesions. Results: Additional tumors were identified in 10(37%) of the 27 study patients by laparoscopy and laparoscopic intraoperative ultrasound despite extensive preoperative imaging. Radiofrequency ablation of 85 hepatic tumors yielded no mortality and only one case of postoperative bleeding. During a mean follow-up period of 14 months, four tumors (4.7%) locally recurred. Of the 27 patients, 11 (41%) remain free of disease at this writing; (22%) are alive with disease: and 10 (37%) have died with disease. Conclusion: Laparoscopic RFA and intraoperative ultrasound constitute a safe and accurate method for ablation of unresectable hepatic tumors.
引用
收藏
页码:1020 / 1026
页数:7
相关论文
共 21 条
  • [11] HEPATIC ABLATION USING RADIOFREQUENCY ELECTROCAUTERY
    MCGAHAN, JP
    BROWNING, PD
    BROCK, JM
    TESLUK, H
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (03) : 267 - 270
  • [12] TREATMENT OF LIVER-TUMORS BY PERCUTANEOUS RADIOFREQUENCY ELECTROCAUTERY
    MCGAHAN, JP
    SCHNEIDER, P
    BROCK, JM
    TESLUK, H
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 1993, 10 (02) : 143 - 149
  • [13] McMurrick Paul J., 1997, Current Opinion in Oncology, V9, P367, DOI 10.1097/00001622-199709040-00010
  • [14] Radiofrequency ablation of porcine liver in vivo -: Effects of blood flow and treatment time on lesion size
    Patterson, EJ
    Scudamore, CH
    Nagy, AG
    Buczkowski, AK
    [J]. ANNALS OF SURGERY, 1998, 227 (04) : 559 - 565
  • [15] Selection of patients for resection of colorectal metastases to the liver using diagnostic laparoscopy and laparoscopic ultrasonography
    Rahusen, FD
    Cuesta, MA
    Borgstein, PJ
    Bleichrodt, RP
    Barkhof, F
    Doesburg, T
    Meijer, S
    [J]. ANNALS OF SURGERY, 1999, 230 (01) : 31 - 37
  • [16] Percutaneous RF interstitial thermal ablation in the treatment of hepatic cancer
    Rossi, S
    DiStasi, M
    Buscarini, E
    Quaretti, P
    Garbagnati, F
    Squassante, L
    Paties, CT
    Silverman, DE
    Buscarini, L
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 759 - 768
  • [17] Rossi S, 1995, Cancer J Sci Am, V1, P73
  • [18] Sarantou T, 1998, SEMIN SURG ONCOL, V14, P156, DOI 10.1002/(SICI)1098-2388(199803)14:2<156::AID-SSU7>3.0.CO
  • [19] 2-4
  • [20] Laparoscopic thermal ablation of hepatic neuroendocrine tumor metastases
    Siperstein, AE
    Rogers, SJ
    Hansen, PD
    Gitomirsky, A
    [J]. SURGERY, 1997, 122 (06) : 1147 - 1154