Activity levels and polyethylene wear of patients 10 years post hip replacement

被引:12
作者
Bennett, D. [1 ]
Humphreys, L. [2 ]
O'Brien, S. [1 ]
Kelly, C. [2 ]
Orr, J. [3 ]
Beverland, D. E. [1 ]
机构
[1] Musgrave Pk Hosp, Outcomes Assessment Unit, Belfast, Antrim, North Ireland
[2] Musgrave Pk Hosp, Gait Anal Lab, Belfast, Antrim, North Ireland
[3] Queens Univ Belfast, Sch Mech & Aerosp Engn, Belfast, Antrim, North Ireland
关键词
hip replacement; activity; pedometer; long-term follow-up;
D O I
10.1016/j.clinbiomech.2007.12.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Wear of the acetabular cup and implant loosening in total hip arthroplasty are thought to be affected by individual patient activity levels. Methods. Activity levels of 100 patients with unilateral primary hip replacements were measured using a digital pedometer 10-years post-operatively. Findings. Activity rates of hip replacement patients 10 years post surgery were found to fall with increasing age strata, with the age group 70-74 years showing significantly reduced activity rates compared to the 55-64 years age group and the age group greater than 80 years showing significantly reduced activity rates compared to both the 55-64 years age group and the 65-69 years age group. However, a clear correlation between age and activity was not found. Acetabular cup wear showed no relationship with patient activity levels. Interpretation. Progressive reduction in activity levels with more elderly hip replacement patients may inform long term planning of hip arthroplasty and implant choice. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:571 / 576
页数:6
相关论文
共 23 条
[1]  
BANKSTON AB, 1995, CLIN ORTHOP RELAT R, P7
[2]   Accuracy of five electronic pedometers for measuring distance walked [J].
Bassett, DR ;
Ainsworth, BE ;
Leggett, SR ;
Mathien, CA ;
Main, JA ;
Hunter, DC ;
Duncan, GE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1996, 28 (08) :1071-1077
[3]   The influence of shape and sliding distance of femoral head movement loci on the wear of acetabular cups in total hip arthroplasty [J].
Bennett, D ;
Orr, JF ;
Beverland, DE ;
Baker, R .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) :393-402
[4]   Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity [J].
Bowsher, JG ;
Hussain, A ;
Williams, PA ;
Shelton, JC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :279-287
[5]  
CALLAGHAN JJ, 1995, CLIN ORTHOP RELAT R, P14
[6]   Measurement of polyethylene wear in acetabular components inserted with and without cement - A randomized trial [J].
Devane, PA ;
Robinson, EJ ;
Bourne, RB ;
Rorabeck, CH ;
Nayak, NN ;
Horne, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :682-689
[7]   Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis [J].
Dowd, JE ;
Sychterz, CJ ;
Young, AM ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (08) :1102-1107
[8]   New joints for the Millennium: wear control in total replacement hip joints [J].
Dowson, D .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H4) :335-358
[9]   Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements [J].
Ebramzadeh, E ;
Sangiorgio, SN ;
Lattuada, F ;
Kang, JS ;
Chiesa, R ;
McKellop, HA ;
Dorr, LD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12) :2378-2384
[10]  
Feller J A, 1994, J Arthroplasty, V9, P341, DOI 10.1016/0883-5403(94)90042-6