Anodic stripping voltammetric measurement of trace cadmium at antimony film modified sodium montmorillonite doped carbon paste electrode

被引:35
作者
Chen, Guo [1 ]
Hao, Xia [1 ]
Li, Bang Lin [1 ]
Luo, Hong Qun [1 ]
Li, Nian Bing [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Minist Educ, Key Lab Ecoenvironm Three Gorges Reservoir Reg, Chongqing 400715, Peoples R China
基金
中国国家自然科学基金;
关键词
Antimony film electrode; Carbon paste electrode; Sodium montmorillonite; Square wave anodic stripping voltammetry; Determination of Cd(II); HEAVY-METALS; BISMUTH; SAMPLES; COPPER(II); LEAD(II); ACETATE; CD(II); PB(II); SENSOR; WATER;
D O I
10.1016/j.snb.2016.06.128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a simple and reliable electrochemical method for the determination of cadmium using an antimony film modified sodium montmorillonite (NaMM) doped carbon paste electrode (Sb/NaMM-CPE) was described. Due to the strong cation exchange ability and adsorptive characteristics of NaMM and excellent electroanalytical performance of the antimony film, the new electrode significantly enhanced the sensitivity for detection of Cd(II) and exhibited superior performance in comparison with the bare carbon paste electrode, antimony film modified carbon paste electrode (Sb/CPE), and NaMM modified carbon paste electrode (NaMM-CPE). Some parameters such as the composition of the paste, pH of the measure solution, the Sb(III) concentration, deposition time, and deposition potential that influenced the response of cadmium were investigated and the procedure was optimized for cadmium determination. This electrode, combined with square-wave anodic stripping voltammetry, displayed excellent linear behavior in the examined concentration range of 4.0-150.0 mu g L-1 Cd(II) (R-2=0.998) with a detection limit of 0.25 mu g L-1. The Sb/NaMM-CPE was successfully applied to the determination of cadmium ion in tap water sample. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:570 / 574
页数:5
相关论文
共 40 条
[1]   Antimony nanoparticle-multiwalled carbon nanotubes composite immobilized at carbon paste electrode for determination of trace heavy metals [J].
Ashrafi, Amir M. ;
Cerovac, Sandra ;
Mudric, Sanja ;
Guzsvany, Valeria ;
Husakova, Lenka ;
Urbanova, Iva ;
Vytras, Karel .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 :320-325
[2]  
Ashrafi AM, 2013, INT J ELECTROCHEM SC, V8, P2095
[3]   New procedures for voltammetric determination of copper (II) using antimony film-coated carbon paste electrodes [J].
Ashrafi, Amir M. ;
Vytras, Karel .
ELECTROCHIMICA ACTA, 2012, 73 :112-117
[4]  
Ashrafi AM, 2012, INT J ELECTROCHEM SC, V7, P68
[5]   Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode [J].
Ashrafi, Amir M. ;
Vytras, Karel .
TALANTA, 2011, 85 (05) :2700-2702
[6]   Sensitive determination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes [J].
Cao, Linyuan ;
Jia, Jianbo ;
Wang, Zhenhui .
ELECTROCHIMICA ACTA, 2008, 53 (05) :2177-2182
[7]  
Committee A. M., 1987, ANALYST, V112, P199
[8]  
Crowley K, 2002, ELECTROANAL, V14, P1077, DOI 10.1002/1521-4109(200208)14:15/16<1077::AID-ELAN1077>3.0.CO
[9]  
2-3
[10]   A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry [J].
Demetriades, D ;
Economou, A ;
Voulgaropoulos, A .
ANALYTICA CHIMICA ACTA, 2004, 519 (02) :167-172