Single versus double row suture anchor fixation for greater tuberosity fractures - a biomechanical study

被引:14
|
作者
Seppel, Gernot [1 ,2 ]
Saier, Tim [1 ,3 ]
Martetschlaeger, Frank [1 ,4 ]
Plath, Johannes E. [1 ,5 ]
Guevara-Alvarez, Alberto [1 ]
Henschel, Julia [6 ]
Winkler, Martin [6 ]
Augat, Peter [6 ,7 ]
Imhoff, Andreas B. [1 ]
Buchmann, Stefan [1 ,8 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Orthoped Sports Med, Ismaninger Str 22, D-81675 Munich, Germany
[2] Krankenhaus Barmherzige Bruder, Dept Orthoped & Trauma Surg, Munich, Germany
[3] Berufsgenossenschaftl Unfallklin Murnau, Dept Reconstruct Joint Surg & Sportstraumatol, Murnau, Germany
[4] ATOS Clin Munich, Ctr Shoulder & Elbow Surg, Munich, Germany
[5] Klinikum Augsburg, Dept Trauma Surg, Augsburg, Germany
[6] Berufsgenossenschaftl Unfallklin Murnau, Inst Biomech, Murnau, Germany
[7] Paracelsus Med Univ, Inst Biomech, Salzburg, Austria
[8] Orthopad Fachzentrum, Weilheim, Germany
来源
BMC MUSCULOSKELETAL DISORDERS | 2017年 / 18卷
关键词
Greater tuberosity fracture; Suture anchor; Arthroscopic; Double row fixation; Single-row; ROTATOR CUFF REPAIR; INTERNAL-FIXATION; PROXIMAL HUMERUS; INFRASPINATUS TENDONS; DISPLACED FRACTURES; OPEN REDUCTION; SUPRASPINATUS; MORPHOLOGY; INSERTION; 2-PART;
D O I
10.1186/s12891-017-1868-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Fractures of the humeral greater tuberosity (GT) are a frequent injury progressively treated with arthroscopic suture anchor repair. Yet, no biomechanical study has been performed comparing fixation strength of arthroscopic single- (SR) vs. double row (DR) fixation. Methods: Standardized fractures of the greater tuberosity were created in 12 fresh frozen proximal humeri. After random assignation to the SR or DR group the fixed humeri were tested applying cyclic loading to the supraspinatus and infraspinatus tendon. Load to failure and fragment displacement were assessed by means of an electrodynamic material testing machine using an optical tracking system. Results: Load to failure values were higher in the DR group (649 N; +/- 176) than in the SR group (490 N; +/- 145) however without statistical significance (p = .12). In greater tuberosity displacement of 3-5 mm surgical treatment is recommended. The fixing constructs in this study did not reach displacement landmarks of 3 or 5 mm before construct failure as shown in previous studies. Thus the applied traction force (N) at 1 mm displacement was analyzed. In the SR group the load at 1 mm displacement was 277 N; +/- 46 compared to 260 N; +/- 62 in the DR group (p = .65). Conclusion: The results suggest that both techniques are viable options for refixation of greater tuberosity fractures.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Arthroscopic reduction and fixation with suture-bridge technique for displaced or comminuted greater tuberosity fractures
    Song, Hyun Seok
    Williams, Gerald R., Jr.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (08) : 956 - 960
  • [32] Radiological and biomechanical assessment of displaced greater tuberosity fractures
    Nyffeler, Richard W.
    Seidel, Angela
    Werlen, Stefan
    Bergmann, Mathias
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1479 - 1486
  • [33] Suture Anchor Fixation in Osteoporotic Bone: A Biomechanical Study in an Ovine Model
    Horoz, Levent
    Hapa, Onur
    Barber, F. Alan
    Husemoglu, Bugra
    Ozkan, Mustafa
    Havitcioglu, Hasan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2017, 33 (01) : 68 - 74
  • [34] Pullout strength of cement-augmented and wide-suture transosseous fixation in the greater tuberosity
    Shi, Brendan Y.
    Diaz, Miguel
    Belkoff, Stephen M.
    Srikumaran, Uma
    CLINICAL BIOMECHANICS, 2017, 50 : 154 - 159
  • [35] Arthroscopic reduction and fixation for isolated greater tuberosity fractures
    Wang Yong-ping
    Zhao Jin-zhong
    Huangfu Xiao-qiao
    Liu Wen-xin
    Jiang Yao
    Zhou Xin-hua
    He Yao-hua
    CHINESE MEDICAL JOURNAL, 2012, 125 (07) : 1272 - 1275
  • [36] Arthroscopic reduction and fixation for displaced greater tuberosity fractures using the modified suture-bridge technique
    Li, RenLong
    Cai, Ming
    Tao, Kun
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (06) : 1257 - 1263
  • [37] Clinical and radiologic outcomes of arthroscopic suture bridge repair for the greater tuberosity fractures of the proximal humerus
    Ji, Jong-Hun
    Jeong, Jae-Jung
    Kim, Young-Yul
    Lee, Se-Won
    Kim, Do-Yeol
    Park, Sang-Eun
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (01) : 9 - 17
  • [38] An in-vitro study of rotator cuff tear and repair kinematics using single- and double-row suture anchor fixation
    Kedgley, Angela E.
    Shore, Benjamin J.
    Athwal, George S.
    Johnson, James A.
    Faber, Kenneth J.
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (02): : 46 - 51
  • [39] Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears
    Zhang Chun-gang
    Zhao De-wei
    Wang Wei-ming
    Ren Ming-fa
    Li Rui-xin
    Yang Sheng
    Liu Yu-peng
    CHINESE MEDICAL JOURNAL, 2010, 123 (21) : 3049 - 3054
  • [40] Double-Row Suture Anchor Fixation and Achilles Allograft Augmentation for Chronic Patellar Tendon Rupture Repair
    Cregar, William
    Fortier, Luc M.
    Kerzner, Benjamin
    Dasari, Suhas P.
    Gursoy, Safa
    Chahla, Jorge
    ARTHROSCOPY TECHNIQUES, 2022, 11 (04): : E631 - E638