摘要
Nickel-titanium (NiTi) wires produced by various manufacturers may have different corrosion resistance in acidic oral environments. The purpose of this study was to investigate the variation during in vitro corrosion resistance of commercial NiTi dental orthodontic wires from different manufacturers using the fast electrochemical technique. The linear polarization test was used to evaluate the corrosion resistance, in terms of polarization resistance (R-p), of as-received commercial NiTi wires in acidic artificial saliva at 37 degrees C. One-way analysis of variance was used to analyze R-p with the wire manufacturer as the variable factor. Atomic force microscopy was used to analyze the three-dimensional surface topography and roughness (R-a). Electron spectroscopy for chemical analysis was used to identify the chemical structure of the passive film on the NiTi wires. The results showed that NiTi wires from different manufacturers had a statistically significant difference in R-p (P <.001). Different surface topography was present among the tested NiTi wires, whereas the same surface chemical structure was observed for the tested NiTi wires. The surface roughness of the commercial NiTi wires with similar surface chemical structure does not correspond with the difference in corrosion resistance.
引用
收藏
页码:661 / 665
页数:5
相关论文
共 24 条
  • [1] GEISGERSTORFER J, 1985, DEUT ZAHNAERZTL Z, V40, P87
  • [2] REACTION TO STAINLESS-STEEL WIRE FOLLOWING ORTHOGNATHIC SURGERY
    GUYURON, B
    LASA, CI
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (03) : 540 - 542
  • [3] Ion release from NiTi orthodontic wires in artificial saliva with various acidities
    Huang, HH
    Chiu, YH
    Lee, TH
    Wu, SC
    Yang, HW
    Su, KH
    Hsu, CC
    [J]. BIOMATERIALS, 2003, 24 (20) : 3585 - 3592
  • [4] Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva
    Huang, HH
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (04) : 829 - 839
  • [5] Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4V alloy
    Huang, HH
    [J]. BIOMATERIALS, 2003, 24 (02) : 275 - 282
  • [6] HUANG HH, 2004, P 12 INT C SOL FILMS, P225
  • [7] Hunt NP, 1999, ANGLE ORTHOD, V69, P433
  • [8] Jones D.A., 1996, PRINCIPLES PREVENTIO, Vsecond ed, P143
  • [9] Kim H, 1999, ANGLE ORTHOD, V69, P39
  • [10] Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
    Köster, R
    Vieluf, D
    Kiehn, M
    Sommerauer, M
    Kähler, J
    Baldus, S
    Meinertz, T
    Hamm, CW
    [J]. LANCET, 2000, 356 (9245) : 1895 - 1897