Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming

被引:27
作者
Diamantis, Konstantinos [1 ]
Anderson, Tom [2 ]
Butler, Mairead B. [1 ]
Villagomez-Hoyos, Carlos A. [3 ]
Jensen, Jorgen Arendt [3 ]
Sboros, Vassilis [1 ]
机构
[1] Heriot Watt Univ, Inst Biol Chem Biophys & Bioengn, Edinburgh EH14 4AS, Midlothian, Scotland
[2] Univ Edinburgh, Sch Clin Sci, Ctr Cardiovasc Sci, Edinburgh EH16 4TJ, Midlothian, Scotland
[3] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
基金
英国科学技术设施理事会;
关键词
Closely-spaced scatterers; microbubbles; Minimum Variance beamforming; lateral resolution; super-resolution ultrasound; IN-VITRO; AGENTS; GPU;
D O I
10.1109/TMI.2018.2859262
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer's performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to 196 mu m (or 1.05 lambda) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers' axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.
引用
收藏
页码:194 / 204
页数:11
相关论文
共 39 条
[1]   Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images [J].
Ackermann, Dimitri ;
Schmitz, Georg .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (01) :72-82
[2]  
[Anonymous], 2010, Diagnostic Ultrasound: Physics and Equipment
[3]   Capon Beamforming and Moving Objects-An Analysis of Lateral Shift-Invariance [J].
Asen, Jon Petter ;
Austeng, Andreas ;
Holm, Sverre .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (07) :1152-1160
[4]   Implementing Capon Beamforming on a GPU for Real-Time Cardiac Ultrasound Imaging [J].
Asen, Jon Petter ;
Buskenes, Jo Inge ;
Nilsen, Carl-Inge Colombo ;
Austeng, Andreas ;
Holm, Sverre .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (01) :76-85
[5]   Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (04) :858-867
[6]   HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS [J].
CAPON, J .
PROCEEDINGS OF THE IEEE, 1969, 57 (08) :1408-&
[7]   In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles [J].
Christensen-Jeffries, Kirsten ;
Browning, Richard J. ;
Tang, Meng-Xing ;
Dunsby, Christopher ;
Eckersley, Robert J. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) :433-440
[8]   Experimental performance assessment of the sub-band minimum variance beamformer for ultrasound imaging [J].
Diamantis, Konstantinos ;
Greenaway, Alan ;
Anderson, Tom ;
Jensen, Jorgen Arendt ;
Sboros, Vassilis .
ULTRASONICS, 2017, 79 :87-95
[9]   A comparison between temporal and subband minimum variance adaptive beamforming [J].
Diamantis, Konstantinos ;
Voxen, Iben H. ;
Greenaway, Alan H. ;
Anderson, Tom ;
Jensen, Jorgen A. ;
Sboros, Vassilis .
MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
[10]   Transcranial functional ultrasound imaging of the brain using microbubble-enhanced ultrasensitive Doppler [J].
Errico, Claudia ;
Osmanski, Bruno-Felix ;
Pezet, Sophie ;
Couture, Olivier ;
Lenkei, Zsolt ;
Tanter, Mickael .
NEUROIMAGE, 2016, 124 :752-761