Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming

被引:27
|
作者
Diamantis, Konstantinos [1 ]
Anderson, Tom [2 ]
Butler, Mairead B. [1 ]
Villagomez-Hoyos, Carlos A. [3 ]
Jensen, Jorgen Arendt [3 ]
Sboros, Vassilis [1 ]
机构
[1] Heriot Watt Univ, Inst Biol Chem Biophys & Bioengn, Edinburgh EH14 4AS, Midlothian, Scotland
[2] Univ Edinburgh, Sch Clin Sci, Ctr Cardiovasc Sci, Edinburgh EH16 4TJ, Midlothian, Scotland
[3] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
基金
英国科学技术设施理事会;
关键词
Closely-spaced scatterers; microbubbles; Minimum Variance beamforming; lateral resolution; super-resolution ultrasound; IN-VITRO; AGENTS; GPU;
D O I
10.1109/TMI.2018.2859262
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer's performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to 196 mu m (or 1.05 lambda) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers' axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.
引用
收藏
页码:194 / 204
页数:11
相关论文
共 50 条
  • [1] Minimum Variance beamforming for closely spaced microbubbles
    Diamantis, Konstantinos
    Butler, Mairead
    Anderson, Tom
    Jensen, Jorgen Arendt
    Sboros, Vassilis
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 571 - 574
  • [2] Broadband Minimum Variance Beamforming for Ultrasound Imaging
    Holfort, Iben Kraglund
    Gran, Fredrik
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) : 314 - 325
  • [3] Ultrasound Contrast Microbubbles Reconstruction Using a Joint Enhanced Mean-to-Standard-Deviation Factor and Minimum Variance Beamformer
    Wang, Yadan
    Wang, Yuanguo
    Zheng, Chichao
    Peng, Hu
    Zhang, Chaoxue
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [4] Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming
    Asl, Babak Mohammadzadeh
    Mahloojifar, Ali
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (04) : 858 - 867
  • [5] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sayed Mahmoud Sakhaei
    Seyede Elham Shamsian
    Journal of Medical Ultrasonics, 2018, 45 : 17 - 24
  • [6] Twofold minimum variance beamforming for enhanced ultrasound imaging
    Sakhaei, Sayed Mahmoud
    Shamsian, Seyede Elham
    JOURNAL OF MEDICAL ULTRASONICS, 2018, 45 (01) : 17 - 24
  • [7] Plane wave ultrasound imaging using compressive sensing and minimum variance beamforming
    Paridar, Roya
    Asl, Babak Mohammadzadeh
    ULTRASONICS, 2023, 127
  • [8] Deep Learning Based Minimum Variance Beamforming for Ultrasound Imaging
    Zhuang, Renxin
    Chen, Junying
    SMART ULTRASOUND IMAGING AND PERINATAL, PRETERM AND PAEDIATRIC IMAGE ANALYSIS, SUSI 2019, PIPPI 2019, 2019, 11798 : 83 - 91
  • [9] Minimum variance adaptive beamforming applied to medical ultrasound imaging
    Synnevag, JF
    Austeng, A
    Holm, S
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1199 - 1202
  • [10] Phase Aberration Correction in Minimum Variance Beamforming of Ultrasound Imaging
    Ziksari, Mahsa Sotoodeh
    Asl, Babak Mohammadzadeh
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 23 - 26