Development of a fimY-based loop-mediated isothermal amplification assay for detection of Salmonella in food

被引:44
作者
Zhang, Yaoqi [1 ]
Shan, Xiaoxiao [2 ]
Shi, Lei [1 ]
Lu, Xi [1 ]
Tang, Shangxing [3 ]
Wang, Yuke [1 ]
Li, Yiming [1 ]
Alam, M. J. [4 ]
Yan, He [1 ]
机构
[1] S China Univ Technol, Coll Light Ind & Food Sci, Guangzhou 510640, Guangdong, Peoples R China
[2] S China Univ Technol, Sch Biol Sci & Bioengn, Guangzhou 510640, Guangdong, Peoples R China
[3] GuangZhou Diao Biotechnol Co LTD, Guangzhou, Guangdong, Peoples R China
[4] Texas Commiss Environm Qual, Houston, TX 77015 USA
基金
中国国家自然科学基金;
关键词
Salmonella detection; LAMP; Real-time turbidimeter; Time threshold value; RAPID DETECTION; GENE; PREVALENCE;
D O I
10.1016/j.foodres.2011.02.015
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, we developed a rapid and sensitive fimY-based loop-mediated isothermal amplification (LAMP) assay on a real-time turbidimeter platform for the detection of Salmonella in food. Since turbidity of the reaction mixture would increase in correlation with the DNA yield, real-time monitoring of the LAMP reaction was achieved by real-time turbidimeter. Time threshold values which indicate positive results for 81 Salmonella strains of different serotypes ranged from 36 to 40 min. For the 20 non-Salmonella strains, turbidity did not increase in the reaction mixture. When testing 10-fold serial dilutions of Salmonella Typhimurium-ATCC 14128 DNA by LAMP, the time threshold ranged from 36 to 52 min on the real-time turbidimeter. The detection limit was 13 cells per reaction in pure culture, up to 10-fold more sensitive than that of PCR. When applied in deli food samples, the LAMP assay was able to detect Salmonella even though the sample was contaminated with very low concentration after 3 h enrichment culture. Increase in turbidity was observed on real-time turbidimeter. Additionally, the LAMP results detected by naked-eye or turbidity consistently matched with each other. Results from this study showed that the fimY-based LAMP assay is an effective method for the rapid detection of Salmonella. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1011 / 1015
页数:5
相关论文
共 23 条
[1]  
Andrews W. H., 1998, FOOD DRUG ADM BACTER
[2]  
Bennett AR, 1998, LETT APPL MICROBIOL, V26, P437, DOI 10.1046/j.1472-765X.1998.00368.x
[3]   Characterization of multiple-antimicrobial-resistant Salmonella serovars isolated from retail meats [J].
Chen, S ;
Zhao, SH ;
White, DG ;
Schroeder, CM ;
Lu, R ;
Yang, HC ;
McDermott, PF ;
Ayers, S ;
Meng, JH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (01) :1-7
[4]   Development of a toxR-based loop-mediated isothermal amplification assay for detecting Vibrio parahaemolyticus [J].
Chen, Siyi ;
Ge, Beilei .
BMC MICROBIOLOGY, 2010, 10
[5]   Sequencing of an internal transcribed spacer region of 16S-23S rRNA gene and designing of PCR primers for the detection of Salmonella spp. in food [J].
Chiu, TH ;
Chen, TR ;
Hwang, WZ ;
Tsen, HY .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2005, 97 (03) :259-265
[6]   Evaluation of a loop-mediated isothermal amplification assay for detecting Vibrio vulnificus in raw oysters [J].
Han, Feifei ;
Ge, Beilei .
FOODBORNE PATHOGENS AND DISEASE, 2008, 5 (03) :311-320
[7]   Loop-mediated isothermal amplification for the rapid detection of Salmonella [J].
Hara-Kudo, Y ;
Yoshino, M ;
Kojima, T ;
Ikedo, M .
FEMS MICROBIOLOGY LETTERS, 2005, 253 (01) :155-161
[8]  
[李永刚 LI Yong-gang], 2010, [食品工业科技, Science & Technology of Food Industry], P388
[9]   Detection of bacteria carrying the stx2 gene by in situ loop-mediated isothermal amplification [J].
Maruyama, F ;
Kenzaka, T ;
Yamaguchi, N ;
Tani, K ;
Nasu, M .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2003, 69 (08) :5023-5028
[10]   Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation [J].
Mori, Y ;
Nagamine, K ;
Tomita, N ;
Notomi, T .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2001, 289 (01) :150-154