Seismic capacity evaluation of a group of vertical U-tube heat exchanger with support frames for seismic PSA

被引:5
|
作者
Watanabe, Y
Muramatsu, K
Oikawa, T
机构
[1] JFE R&D Corp, Numer Simulat Lab, Kawasaki Ku, Kawasaki, Kanagawa 2100855, Japan
[2] Japan Atom Energy Res Inst, Dept Reactor Safety Res, Safety Anal Lab, Tokai, Ibaraki 31911, Japan
[3] Japan Atom Energy Res Inst, Nucl Safety Res Ctr, Tokai, Ibaraki 31911, Japan
关键词
D O I
10.1016/j.nucengdes.2005.05.037
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper presents an evaluation of seismic capacity of a group of vertical U-tube type heat exchangers (HXs) with support frames to contribute to refinement of seismic capacity data for seismic Probabilistic Safety Assessment (PSA) in Japan. According to usual practice of seismic PSAs, capacity of component is represented as a log-normally distributed random variable defined by a median and logarithmic standard deviations (LSDs), which represent inherent randomness about the median, beta(r), and uncertainty in the median due to lack of knowledge, beta(u). Using design specifications of four HXs for residual heat removal systems of 1100 MWe BWRs, the authors evaluated a generic capacity of HXs with a LSD for uncertainty due to lack of knowledge to take into account design variability. The median capacity was evaluated by the use of a time history response analysis with a detailed model for a selected representative HX, which was extended from a model used in seismic design. The LSD for uncertainty due to lack of knowledge was evaluated with consideration of the variabilities in three influential design parameters, i.e., diameter of anchor bolt, weight of HX and position of center of gravity of HX with the detailed model and a simplified static model. The LSD for uncertainty due to randomness was determined from the variability in material property. The dominant failure mode of HXs was identified as the failure of anchor bolts of lugs mainly due to shearing stress. The capacity expressed in terms of zero period acceleration on the foundation of HX was evaluated to be 4180 Gal (4.3 g) for median, LSD for uncertainty due to randomness was 0.11 and LSD due to lack of knowledge was 0.21-0.53 depending on combination of the variabilities in design parameters to be considered. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2495 / 2512
页数:18
相关论文
共 50 条
  • [21] Computer simulation of the U-tube ground heat exchanger for GSHP
    Key Laboratory-Enhanced Heat Transfer and Energy Conservation, College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022, China
    不详
    Beijing Gongye Daxue Xuebao J. Beijing Univ. Technol., 2006, 1 (62-66):
  • [22] A new approach to the analysis of a tubesheet for a U-tube heat exchanger
    Paliwal, DN
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1996, 67 (02) : 181 - 184
  • [23] Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump
    Muraya, NK
    ONeal, DL
    Heffington, WM
    ASHRAE TRANSACTIONS 1996, VOL 102, PT 2, 1996, 102 : 12 - 21
  • [24] Borehole thermal resistance of U-tube borehole heat exchanger
    Abuel-Naga, H. M.
    Al-Chalabi, R. R.
    GEOTECHNIQUE LETTERS, 2016, 6 (04) : 250 - 255
  • [25] Experimental investigation of thermal storage in U-tube heat exchanger
    Cakmak, Gulsah
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 44 : 83 - 86
  • [26] Further investigations in tubesheet design for a U-tube heat exchanger
    Motilal Nehru Regional Engineering, Coll, Allahabad, India
    J Pressure Vessel Technol Trans ASME, 2 (142-145):
  • [27] Experimental and Simulant Study on Vertical U-Tube Underground Heat Exchanger in Ground-Source Heat Pump
    Gao, Zhen
    Ma, Jinwei
    Yu, Xiaochun
    Zhang, Yu
    Hu, Ning
    Wang, Yanping
    PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 636 - 641
  • [28] Performance of Conventional and Innovative Single U-Tube Pipe Configuration in Vertical Ground Heat Exchanger (VGHE)
    Eswiasi, Adel
    Mukhopadhyaya, Phalguni
    SUSTAINABILITY, 2021, 13 (11)
  • [29] A new solution for thermal interference of vertical U-tube ground heat exchanger for cold area in China
    Li, Xiao-Yan
    Li, Tian-Yang
    Qu, Dong-Qi
    Yu, Jia-Wen
    GEOTHERMICS, 2017, 65 : 72 - 80
  • [30] The research on the underground temperature change around the double vertical U-tube ground heat exchanger in winter
    Zhou, Zhihua
    Zhang, Shihua
    Li, Lingan
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1104 - 1110