Seismic capacity evaluation of a group of vertical U-tube heat exchanger with support frames for seismic PSA

被引:5
|
作者
Watanabe, Y
Muramatsu, K
Oikawa, T
机构
[1] JFE R&D Corp, Numer Simulat Lab, Kawasaki Ku, Kawasaki, Kanagawa 2100855, Japan
[2] Japan Atom Energy Res Inst, Dept Reactor Safety Res, Safety Anal Lab, Tokai, Ibaraki 31911, Japan
[3] Japan Atom Energy Res Inst, Nucl Safety Res Ctr, Tokai, Ibaraki 31911, Japan
关键词
D O I
10.1016/j.nucengdes.2005.05.037
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper presents an evaluation of seismic capacity of a group of vertical U-tube type heat exchangers (HXs) with support frames to contribute to refinement of seismic capacity data for seismic Probabilistic Safety Assessment (PSA) in Japan. According to usual practice of seismic PSAs, capacity of component is represented as a log-normally distributed random variable defined by a median and logarithmic standard deviations (LSDs), which represent inherent randomness about the median, beta(r), and uncertainty in the median due to lack of knowledge, beta(u). Using design specifications of four HXs for residual heat removal systems of 1100 MWe BWRs, the authors evaluated a generic capacity of HXs with a LSD for uncertainty due to lack of knowledge to take into account design variability. The median capacity was evaluated by the use of a time history response analysis with a detailed model for a selected representative HX, which was extended from a model used in seismic design. The LSD for uncertainty due to lack of knowledge was evaluated with consideration of the variabilities in three influential design parameters, i.e., diameter of anchor bolt, weight of HX and position of center of gravity of HX with the detailed model and a simplified static model. The LSD for uncertainty due to randomness was determined from the variability in material property. The dominant failure mode of HXs was identified as the failure of anchor bolts of lugs mainly due to shearing stress. The capacity expressed in terms of zero period acceleration on the foundation of HX was evaluated to be 4180 Gal (4.3 g) for median, LSD for uncertainty due to randomness was 0.11 and LSD due to lack of knowledge was 0.21-0.53 depending on combination of the variabilities in design parameters to be considered. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2495 / 2512
页数:18
相关论文
共 50 条
  • [1] Heat extraction characteristics of a vertical U-tube downhole heat exchanger
    Department of Mechanical Engineering, Akita University, 1-1 Tegatagakuen-cho, Akita-shi, Akita, 010-8502, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2008, 5 (1145-1153): : 1145 - 1153
  • [2] Vertical U-tube Ground Heat Exchanger design method research
    Wang, P. Y.
    Tian, H. F.
    Cao, W. W.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 974 - 978
  • [3] Numerical simulation analysis on vertical U-tube underground heat exchanger
    Lian, Xiaoxin
    Liu, Jinxiang
    Chen, Xiaochun
    Li, Ying
    Ding, Gao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2012, 33 (01): : 48 - 55
  • [4] Performance evaluation of a vertical U-tube ground heat exchanger using a numerical simulation approach
    Hu, Pingfang
    Yu, Zhongyi
    Lei, Fei
    Zhu, Na
    Sun, Qiming
    Yuan, Xudong
    APPLIED ENERGY TECHNOLOGY, PTS 1 AND 2, 2013, 724-725 : 909 - +
  • [5] Numerical simulation and experimental validation of a vertical U-tube ground heat exchanger
    Gao, Yike
    Gao, Yan
    Yu, Yong
    Lin, Xinxing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 709 - +
  • [6] Vertical temperature profiles and borehole resistance in a U-tube borehole heat exchanger
    Beier, Richard A.
    Acuna, Jose
    Mogensen, Palne
    Palm, Bjorn
    GEOTHERMICS, 2012, 44 : 23 - 32
  • [7] Analysis of thermal and dynamic comportment of a geothermal vertical U-tube heat exchanger
    Bouhacina, Benamar
    Saim, Rachid
    Benzenine, Hamidou
    Oztop, Hakan F.
    ENERGY AND BUILDINGS, 2013, 58 : 37 - 43
  • [8] Numerical Analysis of the Factors Influencing a Vertical U-Tube Ground Heat Exchanger
    Chen, Shangyuan
    Mao, Jinfeng
    Han, Xu
    Li, Chaofeng
    Liu, Liyao
    SUSTAINABILITY, 2016, 8 (09):
  • [9] Heating system with vapour compressor heat pump and vertical U-tube ground heat exchanger
    Hanuszkiewicz-Drapala, Malgorzata
    Skladzien, Jan
    ARCHIVES OF THERMODYNAMICS, 2010, 31 (04) : 93 - 110
  • [10] New Correlations for Thermal Resistances of Vertical Single U-Tube Ground Heat Exchanger
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, T.C.
    Journal of Thermal Science and Engineering Applications, 2012, 4 (03)