Simple chip-based interfaces for on-line monitoring of supramolecular interactions by nano-ESI MS

被引:21
作者
Brivio, M
Oosterbroek, RE
Verboom, W
van den Berg, A
Reinhoudt, DN
机构
[1] Univ Twente, Lab Supramol Chem & Technol, MESA Inst Nanotechnol, NL-7500 AE Enschede, Netherlands
[2] Univ Twente, BIOS Grp, MESA Inst Nanotechnol, NL-7500 AE Enschede, Netherlands
关键词
D O I
10.1039/b510534j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two simple interfaces were designed and realized, enabling on-line coupling of microfluidics reactor chips to a nanoflow electrospray ionization (NESI) time-of-flight (TOF) mass spectrometer (MS). The interfaces are based on two different approaches: a monolithically integrated design, in which ionization is assisted by on-chip gas nebulization, and a modular approach implying the use of commercially available Picospray(TM) tips. Using reserpine as a reference compound in a 1: 1 mixture of acetonitrile and water revealed that both interfaces provide a remarkably stable mass spectrometric signal ( standard deviations lower than 8% and 1% for the monolithic and modular approaches, respectively). Glass microreactors, containing mixing zones, were fabricated and coupled to the modular interface with perfluoroelastomer Nanoport(TM) fluidics connectors, providing a tool to study chemical reactions on-line. Investigation of the mixing dynamics showed that complete on-chip reagents mixing is achieved within a few tens of milliseconds. Metal - ligand interactions of Zn-porphyrin 1 with pyridine ( 2), 4-ethylpyridine ( 3), 4-phenylpyridine ( 4), N-methylimidazole ( 5), and N-butylimidazole ( 6) in acetonitrile as well as host - guest complexations of beta-cyclodextrin ( 7) with N-(1-adamantyl) acetamide ( 8) or 4-tert-butylacetanilide ( 9) in water were studied by mass spectrometry using themodular NESI-chip interface. From on-chip dilution-based mass spectrometric titrations of Zn-porphyrin 1 with pyridine ( 2) or 4-phenylpyridine ( 4) in acetonitrile K-a-values of 4.6 +/- 0.4 x 10(3) M-1 and 6.5 +/- 1.2 x 10(3) M-1, respectively, were calculated. The K-a-values are about four times larger than those obtained with UV/vis spectroscopy in solution, probably due to a higher ionization efficiency of complexed compared to uncomplexed Zn-porphyrin. For the complexation of N-( 1-adamantyl) acetamide ( 8) with beta-cyclodextrin (7), a K-a-value of 3.6 +/- 0.3 x 10(4) M-1 was obtained, which is in good agreement with that determined by microcalorimetry.
引用
收藏
页码:1111 / 1122
页数:12
相关论文
共 92 条
[71]   Polymer microspray with an integrated thick-film microelectrode [J].
Rohner, TC ;
Rossier, JS ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5353-5357
[72]   CAPPED BISCALIX[4]ARENE-ZN-PORPHYRIN - METALLORECEPTOR WITH A RIGID CAVITY [J].
RUDKEVICH, DM ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF ORGANIC CHEMISTRY, 1995, 60 (20) :6585-6587
[73]   Supramolecular chemistry goes gas phase: the mass spectrometric examination of noncovalent interactions in host-guest chemistry and molecular recognition [J].
Schalley, CA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 194 (01) :11-39
[74]   A new on-chip ESI nozzle for coupling of MS with microfluidic devices [J].
Schilling, M ;
Nigge, W ;
Rudzinski, A ;
Neyer, A ;
Hergenröder, R .
LAB ON A CHIP, 2004, 4 (03) :220-224
[75]   Chaotic mixer for microchannels [J].
Stroock, AD ;
Dertinger, SKW ;
Ajdari, A ;
Mezic, I ;
Stone, HA ;
Whitesides, GM .
SCIENCE, 2002, 295 (5555) :647-651
[76]   Poly(dimethylsiloxane) microchip: microchannel with integrated open electrospray tip [J].
Svedberg, M ;
Veszelei, M ;
Axelsson, J ;
Vangbo, M ;
Nikolajeff, F .
LAB ON A CHIP, 2004, 4 (04) :322-327
[77]   Introduction and general overview of cyclodextrin chemistry [J].
Szejtli, J .
CHEMICAL REVIEWS, 1998, 98 (05) :1743-1753
[78]   Cyclodextrin drug carrier systems [J].
Uekama, K ;
Hirayama, F ;
Irie, T .
CHEMICAL REVIEWS, 1998, 98 (05) :2045-2076
[79]  
Verpoorte E, 2002, ELECTROPHORESIS, V23, P677, DOI 10.1002/1522-2683(200203)23:5<677::AID-ELPS677>3.0.CO
[80]  
2-8