Clinical validation of a 4D-CT based method for lung ventilation measurement in phantoms and patients

被引:20
作者
Nyeng, Tine B. [1 ,2 ]
Kallehauge, Jesper F. [1 ,2 ,3 ]
Hoyer, Morten [1 ,2 ,3 ]
Petersen, Jorgen B. B. [1 ,2 ]
Poulsen, Per R. [1 ,2 ,3 ]
Muren, Ludvig P. [1 ,2 ,3 ]
机构
[1] Aarhus Univ, Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus C, Denmark
[2] Aarhus Univ, Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus C, Denmark
[3] Aarhus Univ, Inst Clin Med, DK-8000 Aarhus C, Denmark
关键词
STEREOTACTIC BODY RADIOTHERAPY; DEFORMABLE IMAGE REGISTRATION; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; FUNCTIONAL AVOIDANCE; CANCER RADIOTHERAPY; SPECT; CT; ALGORITHM; ACCURACY;
D O I
10.3109/0284186X.2011.577096
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Lung cancer patients referred to radiotherapy (RT) often present with regional lung function deficits, and it is therefore of interest to image their lung function prior to treatment. In this study a method was developed that uses a deformable image registration (DIR) between the peak-inhale and peak-exhale phases of a thoracic four-dimensional computed tomography (4D-CT) scan to extract ventilation information. The method calculates the displacement vector fields (DVFs) resulting from the DIR using the Jacobian map approach in order to extract information regarding regional lung volume change. Material and methods. The DVFs resulting from DIRs were analysed to compute the Jacobian determinant of vectors in the field, thus obtaining a map of the vector gradients of the entire registered CT image, i.e. voxel-wise local volume change. Geometric and quantitative validation was achieved using images of both phantoms and patients. In the phantom studies, translations and deformations of known size and direction were introduced to validate both the DIR algorithm and the method as a whole. Furthermore, five patients underwent 4D-CT for planning of stereotactic body RT (SBRT). The patients were immobilised in a stereotactic body frame (SBF) and for each patient, two thoracic 4D-CT scans were acquired, one scan with respiration restricted by an abdominal compression plate and the other under free breathing. Results. In the phantom studies deformation errors were found to be of the order of the expected precision of 3 mm, corresponding to the image slice distance, in lateral and vertical directions. For the longitudinal direction a more pronounced discrepancy was observed, with the algorithm predicting displacement lengths of less than half of the physically introduced deformation. Qualitatively the method performed as expected. In the patient study an inverse consistency test showed deviations of up to 5.8 mm, i.e. almost twice the image slice separation. Jacobian maps of the patient images indicated well-ventilated areas as anatomically expected. Conclusion. The established method provides a means of using a (commercially available) DIR algorithm to obtain a quantitative measure of local lung volume change. With further phantom and patient validation studies, quantitative maps of specific ventilation should be possible to produce and use in a clinical setting.
引用
收藏
页码:897 / 907
页数:11
相关论文
共 37 条
[1]   Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study [J].
Bates, Emma L. ;
Bragg, Christopher M. ;
Wild, Jim M. ;
Hatton, Matthew Q. F. ;
Ireland, Rob H. .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) :32-36
[2]   Stereotactic body radiotherapy for medically inoperable patients with stage I non-small cell lung cancer - A first report of toxicity related to COPD/CVD in a non-randomized prospective phase II study [J].
Baumann, Pia ;
Nyman, Jan ;
Hoyer, Morten ;
Gagliardi, Giovanna ;
Lax, Ingmar ;
Wennberg, Berit ;
Drugge, Ninni ;
Ekberg, Lars ;
Friesland, Signe ;
Johansson, Karl-Axel ;
Lund, Jo-Asmund ;
Morhed, Elisabeth ;
Nilsson, Kristina ;
Levin, Nina ;
Paludan, Merete ;
Sederholm, Christer ;
Traberg, Anders ;
Wittgren, Lena ;
Lewensohn, Rolf .
RADIOTHERAPY AND ONCOLOGY, 2008, 88 (03) :359-367
[3]   RESULTS OF A MULTI-INSTITUTION DEFORMABLE REGISTRATION ACCURACY STUDY (MIDRAS) [J].
Brock, Kristy K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02) :583-596
[4]   The incorporation of SPECT functional lung imaging into inverse radiotherapy planning for non-small cell lung cancer [J].
Christian, JA ;
Partridge, M ;
Nioutsikou, E ;
Cook, G ;
McNair, HA ;
Cronin, B ;
Courbon, F ;
Bedford, JL ;
Brada, M .
RADIOTHERAPY AND ONCOLOGY, 2005, 77 (03) :271-277
[5]   CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985
[6]   Assessment of a commercially available automatic deformable registration system [J].
Fallone, B. Gino ;
Rivest, D. Ryan C. ;
Riauka, Terence A. ;
Murtha, Albert D. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03) :101-123
[7]   Dose-response relationship for radiation-induced pneumonitis after pulmonary stereotactic body radiotherapy [J].
Guckenberger, Matthias ;
Baier, Kurt ;
Polat, Buelent ;
Richter, Anne ;
Krieger, Thomas ;
Wilbert, Juergen ;
Mueller, Gerd ;
Flentje, Michael .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (01) :65-70
[8]  
Guerrero T, 2006, PHYS MED BIOL, V51, P777, DOI [10.1088/0031-9155/51/4/002, 10.1088/0031-9155/-51/4/002]
[9]   Quantification of regional ventilation from treatment planning CT [J].
Guerrero, T ;
Sanders, K ;
Noyola-Martinez, J ;
Castillo, E ;
Zhang, Y ;
Tapia, R ;
Guerra, R ;
Borghero, Y ;
Komaki, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (03) :630-634
[10]  
Helminen H, 2003, LECT NOTES COMPUT SC, V2879, P821