Ultrasonic time domain technique for frequency dependent attenuation measurement for microstructural characterization of a titanium alloy

被引:0
|
作者
Kumar, A [1 ]
Jayakumar, T
Raj, B
Ray, KK
机构
[1] Indira Gandhi Ctr Atom Res, Met & Mat Grp, Kalpakkam 603102, Tamil Nadu, India
[2] Indian Inst Technol, Kharagpur 721302, W Bengal, India
关键词
spectral analysis; time domain analysis; ultrasonic attenuation; titanium alloys;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The backwall echo in the ultrasonic pulse echo technique consists of more,than one peak. The ratio of these peaks changes as the ultrasonic waves travel through the specimens with different attenuation. The ratio of the first two peaks in the first backwall echo (the time domain peak ratio) has been used as an ultrasonic parameter for microstructural characterization in Ti-45Al-3Mo-1V (VT14). The time domain peak ratio has been found to vary linearly with the ratio of the twopeaks in the autopower spectrum (the amplitude of the lower frequency peak to that of the higher frequency peak), the spectral peak ratio. The time domain peak ratio is found to be independent of the coupling condition, thus enhancing the reliability of its usage. Further, it has also been shown, both mathematically and graphically, that the linear correlation between the time domain peak ratio and the spectral peak ratio is valid for any transducer exhibiting double peak behavior in the autopower spectrum.
引用
收藏
页码:1321 / 1326
页数:6
相关论文
共 50 条
  • [1] Evaluation of a frequency-domain ultrasonic imaging attenuation compensation technique
    Rouyer, Julien
    Varray, Francois
    Pozo, Edmundo
    Basset, Olivier
    Cachard, Christian
    Lavarello, Roberto
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1560 - 1563
  • [2] FREQUENCY-DOMAIN PROCESSING FOR ULTRASONIC-ATTENUATION MEASUREMENT IN LIVER
    WILSON, LS
    ROBINSON, DE
    DOUST, BD
    ULTRASONIC IMAGING, 1984, 6 (03) : 278 - 292
  • [3] On the measurement of frequency-dependent ultrasonic attenuation in strongly heterogeneous materials
    Molero, M.
    Segura, I.
    Aparicio, S.
    Hernandez, M. G.
    Izquierdo, M. A. G.
    ULTRASONICS, 2010, 50 (08) : 824 - 828
  • [4] Creep degradation characterization of titanium alloy using nonlinear ultrasonic technique
    Xiang, Yanxun
    Zhu, Wujun
    Liu, Chang-Jun
    Xuan, Fu-Zhen
    Wang, Yi-Ning
    Kuang, Wen-Chuan
    NDT & E INTERNATIONAL, 2015, 72 : 41 - 49
  • [5] Characterization of microstructural anisotropy using the mode-converted ultrasonic scattering in titanium alloy
    Du, Hualong
    ULTRASONICS, 2022, 119
  • [6] Simultaneous measurement of ultrasonic velocity and attenuation loss: A new analyzing algorithm in frequency domain
    Yoneda, A
    Song, M
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2003, 67 (18) : A569 - A569
  • [7] MEASUREMENT OF ULTRASONIC ATTENUATION IN SOLIDS BY A REVERBERATION TECHNIQUE
    LANGE, JN
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1963, 35 (11): : 1883 - &
  • [8] TIME DOMAIN EFFECTS OF FREQUENCY-DEPENDENT LINEAR ATTENUATION MECHANISMS
    LUNDQUIST, GM
    CORMIER, VF
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1978, 59 (12): : 1129 - 1129
  • [9] IMPROVED CW TECHNIQUE FOR MEASUREMENT OF ULTRASONIC ATTENUATION
    LEISURE, RG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (07): : 1021 - &
  • [10] Ultrasonic frequency-dependent amplitude attenuation characteristics technique for nondestructive evaluation of concrete
    Ju, J. Woody
    Weng, Li-Sheng
    Liu, Yi