3-D Imaging Using Row-Column-Addressed Arrays With Integrated Apodization-Part II: Transducer Fabrication and Experimental Results

被引:100
作者
Christiansen, Thomas Lehrmann [1 ]
Rasmussen, Morten Fischer [2 ]
Bagge, Jan Peter [3 ]
Moesner, Lars Nordahl [3 ]
Jensen, Jorgen Arendt [2 ]
Thomsen, Erik Vilain [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, Dept Elect Engn, DK-2800 Lyngby, Denmark
[3] BK Med ApS, Anal Ultrasound Grp, DK-2730 Herlev, Denmark
关键词
MICROMACHINED ULTRASONIC TRANSDUCERS; 2-D CMUT ARRAYS; DESIGN; SOUND;
D O I
10.1109/TUFFC.2014.006819
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper demonstrates the fabrication, characterization, and experimental imaging results of a 62+62 element lambda/2-pitch row-column-addressed capacitive micromachined ultrasonic transducer (CMUT) array with integrated apodization. A new fabrication process was used to manufacture a 26.3 mm by 26.3 mm array using five lithography steps. The array includes an integrated apodization, presented in detail in Part I of this paper, which is designed to reduce the amplitude of the ghost echoes that are otherwise prominent for row-column-addressed arrays. Custom front-end electronics were produced with the capability of transmitting and receiving on all elements, and the option of disabling the integrated apodization. The center frequency and -6-dB fractional bandwidth of the array elements were 2.77 +/- 0.26 MHz and 102 +/- 10%, respectively. The surface transmit pressure at 2.5 MHz was 590 +/- 73 kPa, and the sensitivity was 0.299 +/- 0.090 V/Pa. The nearest neighbor crosstalk level was -23.9 +/- 3.7 dB, while the transmit-to-receive-elements crosstalk level was -40.2 +/- 3.5 dB. Imaging of a 0.3-mm-diameter steel wire using synthetic transmit focusing with 62 single-element emissions demonstrated axial and lateral FWHMs of 0.71 mm and 1.79 mm (f-number: 1.4), respectively, compared with simulated axial and lateral FWHMs of 0.69 mm and 1.76 mm. The dominant ghost echo was reduced by 15.8 dB in measurements using the integrated apodization compared with the disabled configuration. The effect was reproduced in simulations, showing a ghost echo reduction of 18.9 dB.
引用
收藏
页码:959 / 971
页数:13
相关论文
共 46 条
[1]   Sparse 2-D Arrays for 3-D phased array imaging - Design methods [J].
Austeng, A ;
Holm, S .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) :1073-1086
[2]   Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays [J].
Bayram, Baris ;
Kupnik, Mario ;
Yaralioglu, Coksen G. ;
Oralkan, Omer ;
Ergun, Arif Sanli ;
Lin, Der-Song ;
Wong, Serena H. ;
Khuri-Yakub, Butrus T. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (02) :418-430
[3]  
Blaak S., 2009, 2009 IEEE International Ultrasonics Symposium, P1338, DOI 10.1109/ULTSYM.2009.5441534
[4]   Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays [J].
Brunke, SS ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) :1101-1109
[5]   Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging [J].
Chee, Ryan K. W. ;
Sampaleanu, Alexander ;
Rishi, Deepak ;
Zemp, Roger J. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) :1393-1395
[6]   A CMUT-based Real-time Volumetric Ultrasound Imaging System with Row-Column Addressing [J].
Chen, Albert I. H. ;
Wong, Lawrence L. ;
Logan, Andrew S. ;
Yeow, John T. W. .
2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, :1755-1758
[7]   Row-Column Addressed 2-D CMUT Arrays with Integrated Apodization [J].
Christiansen, Thomas Lehrmann ;
Rasmussen, Morten Fischer ;
Jensen, Jorgen Arendt ;
Thomsen, Erik Vilain .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :600-603
[8]   Void-Free Direct Bonding of CMUT Arrays with Single Crystalline Plates and Pull-In Insulation [J].
Christiansen, Thomas Lehrmann ;
Hansen, Ole ;
Johnsen, Mathias Dahl ;
Lohse, Jeppe Nyskjold ;
Jensen, Jorgen Arendt ;
Thomsen, Erik V. .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :1737-1740
[9]   2-D army for 3-D ultrasound imaging using synthetic aperture techniques [J].
Daher, NM ;
Yen, JT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) :912-924
[10]  
Daher NM, 2004, ULTRASON, P1270