MELCOR modeling and sensitivity analysis of Fukushima Daiichi unit 2 accident considering the latest TEPCO investigations

被引:9
作者
Li, Gen [1 ]
Zhang, Jun [1 ]
Qiu, Binbin [1 ]
Liu, Ming [1 ]
Yan, Junjie [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Fukushima; Severe accident; Sensitivity analysis; MELCOR;
D O I
10.1016/j.anucene.2017.10.029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Fukushima Daiichi accident occurred on 11 March 2011 due to the Great East japan Earthquake and the following tsunami. Recently, Tokyo Electric Power Company (TEPCO) published investigation reports pertaining to the status of unit 2 and other issues that were confirmed. The present study modeled unit 2 accident with MELCOR 2.1 code and performed sensitivity analysis, in order to provide information towards understanding severe accident. The two-phase flow rate and its void fraction in the steam line connecting to the turbine of reactor core isolation cooling (RCIC) system were calculated using the developed RCIC operation model, and the pump injection rate was obtained as well. The suppression chamber (S/C) was divided into three layers with flow path connection to model thermal stratification and the mixing flow at SRV discharge, thereby enabling to capture the measured dry well (D/W) pressure. Through sensitivity analysis of seawater injection, it indicates that the likely seawater injection rate was about 1-2% of the total flow rate through fire engines, and the corresponding reactor pressure vessel (RPV) lower head failure time was located in 92.84 h- 96.17 h. As a result, about 74% of total fuel debris discharged into the reactor pedestal, and the release fractions of noble gas, iodine and cesium to the environment were about 0.741, 0.0167 and 0.00331, respectively. Even though the plausible accident progression was tentatively given, there are still many uncertainties concerning models, boundary conditions and the accident progression. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:364 / 373
页数:10
相关论文
共 18 条
  • [1] [Anonymous], 2012, FIN REP
  • [2] [Anonymous], 2014, THESIS
  • [3] Simulation of the core degradation phase of the Fukushima accidents using the ASTEC code
    Bonneville, H.
    Luciani, A.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2014, 272 : 261 - 272
  • [4] Examination Committee on Accident at Fukushima Daiichi Nuclear Power Station, 2011, EX ACC TOK EL POW CO
  • [5] Humphries L. L., 2015, SAND20156691R, V1
  • [6] Institute of Nuclear Power Operations, 2011, 11005 INPO
  • [7] Analysis of Fukushima unit 2 accident considering the operating conditions of RCIC system
    Kim, Sung Il
    Park, Jong Hwa
    Ha, Kwang Soon
    Cho, Song-Won
    Song, JinHo
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2016, 298 : 183 - 191
  • [8] Phillips J., 2012, ANS WINT M NUCL TECH
  • [9] Sevon T., 2013, 22 INT C NUCL EN NEW
  • [10] Tokyo Electric Power Company Holdings Inc, 2017, PRE INV RES AR INS P