Augmented Reality during Open Liver Surgery Using a Markerless Non-rigid Registration System

被引:50
作者
Golse, Nicolas [1 ,2 ,3 ,4 ,5 ]
Petit, Antoine [5 ]
Lewin, Maite [6 ]
Vibert, Eric [1 ,2 ,3 ,4 ]
Cotin, Stephane [5 ]
机构
[1] Hop Paul Brousse, AP HP, Dept Surg, Ctr Hepatobiliaire, 12 Ave Paul Vaillant Couturier, F-94804 Villejuif, France
[2] DHU Hepatinov, F-94800 Villejuif, France
[3] INSERM, Unit 1193, F-94800 Villejuif, France
[4] Univ Paris Sud, UMR S 1193, F-94800 Villejuif, France
[5] INRIA, Strasbourg, France
[6] Hop Paul Brousse, AP HP, Dept Radiol, Ctr Hepatobiliaire, F-94800 Villejuif, France
关键词
Augmented reality; Liver resection; Non-rigid registration; RGB-D camera; LESIONS;
D O I
10.1007/s11605-020-04519-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Introduction Intraoperative navigation during liver resection remains difficult and requires high radiologic skills because liver anatomy is complex and patient-specific. Augmented reality (AR) during open liver surgery could be helpful to guide hepatectomies and optimize resection margins but faces many challenges when large parenchymal deformations take place. We aimed to experiment a new vision-based AR to assess its clinical feasibility and anatomical accuracy. Patients and Methods Based on preoperative CT scan 3-D segmentations, we applied a non-rigid registration method, integrating a physics-based elastic model of the liver, computed in real time using an efficient finite element method. To fit the actual deformations, the model was driven by data provided by a single RGB-D camera. Five livers were considered in this experiment. In vivo AR was performed during hepatectomy (n = 4), with manual handling of the livers resulting in large realistic deformations. Ex vivo experiment (n = 1) consisted in repeated CT scans of explanted whole organ carrying internal metallic landmarks, in fixed deformations, and allowed us to analyze our estimated deformations and quantify spatial errors. Results In vivo AR tests were successfully achieved in all patients with a fast and agile setup installation (< 10 min) and real-time overlay of the virtual anatomy onto the surgical field displayed on an external screen. In addition, an ex vivo quantification demonstrated a 7.9 mm root mean square error for the registration of internal landmarks. Conclusion These first experiments of a markerless AR provided promising results, requiring very little equipment and setup time, yet providing real-time AR with satisfactory 3D accuracy. These results must be confirmed in a larger prospective study to definitively assess the impact of such minimally invasive technology on pathological margins and oncological outcomes.
引用
收藏
页码:662 / 671
页数:10
相关论文
共 32 条
  • [31] Remnant liver volume to body weight ratio ≥ 0.5%:: A new cut-off to estimate postoperative risks after extended resection in noncirrhotic liver
    Truant, Stephanie
    Oberlin, Olivier
    Sergent, Geraldine
    Lebuffe, Gilles
    Gambiez, Luc
    Ernst, Olivier
    Pruvot, Francois-Rene
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2007, 204 (01) : 22 - 33
  • [32] VIGAN L, 2016, EUR J SURG ONCOL