The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT

被引:60
作者
Bootsma, G. J. [1 ,2 ]
Verhaegen, F. [3 ,4 ]
Jaffray, D. A. [1 ,2 ,5 ,6 ]
机构
[1] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[2] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[3] Maastricht Univ Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, NL-6201 BN Maastricht, Netherlands
[4] McGill Univ, Dept Oncol, Montreal, PQ H3A 2T5, Canada
[5] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[6] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
X-ray scatter; cone-beam CT; Monte Carlo; bowtie filter; simulation; BEAM COMPUTED-TOMOGRAPHY; MONTE-CARLO-SIMULATION; FAN-BEAM; EFFICIENCY IMPROVEMENTS; PRIMARY MODULATION; CT; RADIATION; LOCALIZATION; REDUCTION; ACCURACY;
D O I
10.1118/1.3539575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: X-ray scatter contributes significantly to image degradation in cone-beam CT (CBCT) reconstructed images in the form of CT number inaccuracy image artifacts and loss of contrast. The need for an understanding of the relationship between the scatter distribution and common imaging parameters (cone angle, air gap, filtration, object size) is an essential element to developing methods for efficiently correcting for the effects of scatter in CBCT. The first objective of this study is to validate the scatter distributions calculated using a CBCT Monte Carlo (MC) model against measured scatter estimates. The second objective is to use the CBCT MC model to investigate the effects of common imaging parameters and bowtie compensators on the resulting scatter distribution. Methods: This investigation employs the use of a CBCT MC model, developed using the EGSnrc code, to simulate the primary and scatter fluence arriving at the detector. The simulation is validated against projection images, scatter-to-open field ratio (SOR), and scatter-to-primary ratio (SPR) measurements taken using a bench-top CBCT system. The CBCT MC model is used to simulate the scatter distribution arriving at the detector for different cone angles {1.4 degrees, 2.8 degrees, 5.7 degrees, and 11.3 degrees}, source-to-axis distances (SADs) {50, 75 and 100 cm}, and axis-to-detector distances (ADDs) {9, 18, 30, 44, 56 cm} for both a 16.4 and 30.6 cm diameter water cylinder. The effects of different bowtie filters are also simulated using the CBCT MC model for the aforementioned cylinder sizes. Results: Profiles of the simulated and measured projection images agree within 6%. The measurements of the SOR and SPR, taken using beam stop techniques, show good agreement with the simulated results. Limitations of current beam stop techniques in estimating scatter profiles of objects with varying thickness are also demonstrated. A functional relationship between scatter (SOR, SPR) and air gap, cone angle is reported. The bowtie filter was found to have the beneficial effect of decreasing the magnitude of scatter in the projection images (SPR decreased by 56%) as well as altering the spatial distribution of the scatter. Conclusions: The CBCT MC model accurately simulates scatter and primary fluences in the CBCT imaging components and geometry. The CBCT MC model provides a useful tool in investigating the effects of varying CBCT imaging parameters on the scatter distribution. Increasing the air gap, decreasing the cone angle, and the use of bowtie filtration were all found to be effective ways to minimize scatter in CBCT. The bowtie filter was particularly effective in both minimizing the magnitude and modifying the spatial distribution of the scattered photons. This observation directs further research in optimizing bowtie filter design in an effort to minimize scatter induced artifacts. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3539575]
引用
收藏
页码:897 / 914
页数:18
相关论文
共 53 条
[1]   Quantifying the effect of off-focal radiation on the output of kilovoltage x-ray systems [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
MEDICAL PHYSICS, 2008, 35 (09) :4149-4160
[2]   Efficiency improvements of x-ray simulations in EGSnrc user-codes using bremsstrahlung cross-section enhancement (BCSE) [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
MEDICAL PHYSICS, 2007, 34 (06) :2143-2154
[3]   Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam x-ray CT [J].
Ay, MR ;
Zaidi, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4863-4885
[4]   Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery [J].
Bachar, G. ;
Siewerdsen, J. H. ;
Daly, M. J. ;
Jaffray, D. A. ;
Irish, J. C. .
MEDICAL PHYSICS, 2007, 34 (12) :4664-4677
[5]   Potential of software-based scatter corrections in cone-beam volume CT [J].
Bertram, M ;
Wiegert, J ;
Rose, G .
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 :259-270
[6]  
Bertram M, 2008, P SPIE
[7]   MONTE-CARLO SIMULATION OF THE SCATTERED RADIATION DISTRIBUTION IN DIAGNOSTIC-RADIOLOGY [J].
BOONE, JM ;
SEIBERT, JA .
MEDICAL PHYSICS, 1988, 15 (05) :713-720
[8]   PHYSICAL CHARACTERISTICS OF SCATTERED RADIATION IN DIAGNOSTIC-RADIOLOGY - MONTE-CARLO SIMULATION STUDIES [J].
CHAN, HP ;
DOI, K .
MEDICAL PHYSICS, 1985, 12 (02) :152-165
[9]   Characterization of scatter in cone-beam CT breast imaging: Comparison of experimental measurements and Monte Carlo simulation [J].
Chen, Yu ;
Liu, Bob ;
O'Connor, J. Michael ;
Didier, Clay S. ;
Glick, Stephen J. .
MEDICAL PHYSICS, 2009, 36 (03) :857-869
[10]   Accelerated simulation of cone beam X-ray scatter projections [J].
Colijn, AP ;
Beekman, FJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :584-590