Hematologic Effects of Continuous Flow Left Ventricular Assist Devices

被引:94
作者
Slaughter, Mark S. [1 ,2 ]
机构
[1] Univ Louisville, Div Thorac & Cardiovasc Surg, Louisville, KY 40202 USA
[2] Univ Louisville, Mech Assist Device & Heart Transplant Program, Louisville, KY USA
关键词
Continuous flow; LVAD; Bleeding; Thromboembolism; Acquired von Willebrand's disease; AORTIC-VALVE STENOSIS; VON-WILLEBRAND-DISEASE; ADVANCED HEART-FAILURE; CIRCULATORY SUPPORT; HEYDE-SYNDROME; GASTROINTESTINAL ANGIODYSPLASIA; ARTERIOVENOUS-MALFORMATIONS; PLATELET-AGGREGATION; CLINICAL-EVALUATION; COAGULATION;
D O I
10.1007/s12265-010-9222-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The extent of hematologic effects of the new continuous flow left ventricular assist devices (CF-LVAD) has not been studied. Recent clinical studies have demonstrated that hemolysis and thrombosis are not common during CF-LVAD support, however, the incidence of bleeding remains a concern. The rate of postoperative bleeding is similar to that of the prior generation pulsatile LVAD, but gastrointestinal bleeding due to angiodysplasia and arteriovenous malformations is more common and appears to be related to the blood flow rheology of these devices. New evidence suggests that acquired von Willebrand's disease develops in some patients due to the reduction in high molecular weight (HMW) multimers of von Willebrand's factor (vWF). Similar to acquired von Willebrand's disease seen in patients with aortic stenosis, the shear stress of the CF-LVAD may cause proteolysis of the HMW multimers of vWF. In addition to acquired von Willebrand's disease, there is activation of the fibrinolytic system and a loss of platelet numbers and function during CF-LVAD support. The hematologic responses during CF-LVAD support are constantly changing, and antiplatelet therapy may need to be adjusted accordingly. Considerable research is needed to better define the complex hematologic effects during CF-LVAD support. Screening of patients for angiodysplasia and von Willebrand's disease before CF-LVAD implant may allow for effective preemptive treatment. Because bleeding causes significant morbidity for this population, more effective treatment strategies need to be developed.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 41 条
[1]   Increased prevalence of aortic stenosis in patients with arteriovenous malformations of the gastrointestinal tract in Heyde syndrome [J].
Batur, P ;
Stewart, WJ ;
Isaacson, JH .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (15) :1821-1824
[2]   Extensive coagulation monitoring in patients after implantation of the MicroMed Debakey continuous flow axial pump [J].
Bonaros, N ;
Mueller, MR ;
Salat, A ;
Schima, H ;
Roethy, W ;
Rocher, AA ;
Wolner, E ;
Wieselthaler, GM .
ASAIO JOURNAL, 2004, 50 (05) :424-431
[3]   Low Thromboembolism and Pump Thrombosis With the HeartMate II Left Ventricular Assist Device: Analysis of Outpatient Anti-coagulation [J].
Boyle, Andrew J. ;
Russell, Stuart D. ;
Teuteberg, Jeffrey J. ;
Slaughter, Mark S. ;
Moazami, Nader ;
Pagani, Francis D. ;
Frazier, O. Howard ;
Heatley, Gerald ;
Farrar, David J. ;
John, Ranjit .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (09) :881-887
[4]  
CAPPELL MS, 1986, ANN INTERN MED, V105, P54, DOI 10.7326/0003-4819-105-1-54
[5]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[6]   Direct thrombolytic therapy for intraventricular thrombosis in patients with the Jarvik 2000 left ventricular assist device [J].
Delgado, R ;
Frazier, OH ;
Myers, TJ ;
Gregoric, ID ;
Robertson, K ;
Shah, NA ;
Kar, B .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02) :231-233
[7]  
FRAZIER OH, 1992, ANN THORAC SURG, V53, P1080, DOI 10.1016/0003-4975(92)90393-I
[8]   Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease [J].
Geisen, Ulrich ;
Heilmann, Claudia ;
Beyersdorf, Friedhelm ;
Benk, Christoph ;
Berchtold-Herz, Michael ;
Schlensak, Christian ;
Budde, Ulrich ;
Zieger, Barbara .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) :679-684
[9]   Worldwide experience with the MicroMed DeBakey ventricular assist device® as a bridge to transplantation [J].
Goldstein, DJ .
CIRCULATION, 2003, 108 (10) :272-277
[10]   POSTCARDIOTOMY SHOCK - CLINICAL-EVALUATION OF THE BVS-5000 BIVENTRICULAR SUPPORT SYSTEM [J].
GUYTON, RA ;
SCHONBERGER, JPAM ;
EVERTS, PAM ;
JETT, GK ;
GRAY, LA ;
GIELCHINSKY, I ;
RAESS, DH ;
VLAHAKES, GJ ;
WOOLLEY, SR ;
GANGAHAR, DM ;
SOLTANZADEH, H ;
PICCIONE, WJ ;
VAUGHN, CC ;
BOONSTRA, PW ;
BUCKLEY, MJ .
ANNALS OF THORACIC SURGERY, 1993, 56 (02) :346-356