A Physiologically Gated Micro-CT Scanner for Dynamic Small Animal Imaging Based On a Carbon Nanotube X-Ray Source

被引:0
|
作者
Cao, G.
Peng, R.
Lee, Y.
Rajaram, R.
Calderon-Colon, X.
An, L.
Phan, T.
Lalush, D.
Lu, J.
Zhou, O.
机构
关键词
D O I
10.1118/1.2961573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-GG-J-16
引用
收藏
页码:2682 / +
页数:2
相关论文
共 50 条
  • [1] A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source
    Cao, G.
    Lee, Y. Z.
    Peng, R.
    Liu, Z.
    Rajaram, R.
    Calderon-Colon, X.
    An, L.
    Wang, P.
    Phan, T.
    Sultana, S.
    Lalush, D. S.
    Lu, J. P.
    Zhou, O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2323 - 2340
  • [2] X-ray micro-CT scanner for small animal imaging based on Timepix detector technology
    Dudak, Jan
    Zemlicka, Jan
    Krejci, Frantisek
    Polansky, Stepan
    Jakubek, Jan
    Mrzilkova, Jana
    Patzelt, Matej
    Trnka, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 773 : 81 - 86
  • [3] Micro-CT system for small animal imaging with ultrafast laser-based x-ray source
    Krol, A
    Kieffer, JC
    Chen, L
    Toth, R
    Coman, LL
    Lipson, ED
    Kincaid, RE
    Chamberlain, CC
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1516 - 1519
  • [4] Respiratory-gated micro-CT using a carbon nanotube based micro-focus field emission x-ray source
    Cao, Guohua
    Lee, Yueh Z.
    Liu, Zejian
    Rajaram, Ramya
    Peng, Rui
    Calderon-Colon, Xiomara
    An, Lei
    Wang, Peng
    Phan, Tuyen
    Lalush, David
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [5] Small Animal X-ray Micro-CT with Zoom-in Imaging Capability
    Lee, Soo Yeol
    Cho, Min Hyoung
    Lee, Sang Chul
    Chun, In Kon
    Park, Jeong Jin
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3102 - 3105
  • [6] Investigation of Sparse Data Mouse Imaging Using Micro-CT with a Carbon-Nanotube-Based X-ray Source
    SIDKY Emil Y
    ZHOU Otto
    TsinghuaScienceandTechnology, 2010, 15 (01) : 74 - 78
  • [7] Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose
    Gong, Hao
    Lu, Jianping
    Zhou, Otto
    Cao, Guohua
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [8] Performance characteristics of the Inveon micro-CT scanner in small animal imaging
    Khalil, Magdy Mohamed
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):
  • [9] Micro-CT scanner with a focusing polycapillary x-ray optic
    Jorgensen, SM
    Reyes, DA
    MacDonald, CA
    Ritman, EL
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 158 - 166
  • [10] Design and Characterization of a Carbon Nanotube based Micro-Focus X-Ray Tube for Small Animal Imaging
    Sultana, Shabana
    Calderon-Colon, Xiomara
    Cao, Guohua
    Zhou, Otto
    Lu, Jianping
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622