In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony

被引:61
作者
Dominguez-Vicent, Alberto [1 ,2 ]
Juan Esteve-Taboada, Jose [1 ]
Del Aguila-Carrasco, Antonio J. [1 ]
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp GIO, Valencia, Spain
[2] Univ Valencia, Dept Opt, C Dr Moliner 50, E-46100 Burjassot, Spain
关键词
Multifocal intraocular lens; In vitro measurements; Extended depth of focus; Optical quality; MODULATION TRANSFER-FUNCTION; INTRAOCULAR-LENS DESIGNS; BILATERAL IMPLANTATION; VISUAL FUNCTION; PATIENT SATISFACTION; FUNCTIONAL OUTCOMES; IMAGE QUALITY; PERFORMANCE; TILT; SIZE;
D O I
10.1007/s00417-015-3240-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the optical quality between two intraocular lenses (IOLs): the Mini WELL Ready progressive multifocal (SIFI Medtech, Catania, Italy), and the TECNIS Symfony (Abbott Laboratories, Illinois, USA), which both provide a continuous range of vision from far to near positions. The in vitro optical quality of each lens was assessed with an instrument conceived for measuring the modulation transfer function (MTF). The optical quality of each lens was described in terms of MTF, through-focus MTF, defocus tolerance, pupil dependence, and Strehl ratio MTF. These metrics were assessed for the best lens far focus, and at four vergences (from -1.5 to -3.0 D in 0.5-D steps), at 3.0 and 4.5 mm apertures. The through-focus curves of each lens showed two main areas: one corresponding to far-distance vision, and another to intermediate- and near-distance vision. Both lenses showed similar MTF curves and Strehl ratio values at both apertures. The optical quality of both lenses slightly decreased with the aperture for all vergences. Nevertheless, the quality of the progressive multifocal lens increased with the aperture at far-distance vision. This lens also showed the largest defocus tolerance at near-distance vision for both apertures. The results obtained in the present study suggest that both designs might enlarge the depth of focus. Whereas, the Mini WELL Ready showed better optical quality than the TECNIS Symfony at far vision with 4.5 mm aperture, and larger defocus tolerance than the diffractive lens at near-distance vision.
引用
收藏
页码:1387 / 1397
页数:11
相关论文
共 27 条
  • [11] KOCH DD, 1991, OPHTHALMOLOGY, V98, P1030
  • [12] The quality of life associated with presbyopia
    Luo, Betsy P.
    Brown, Gary C.
    Luo, Solomon C.
    Brown, Melissa M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (04) : 618 - 622
  • [13] Optical Quality Differences Between Three Multifocal Intraocular Lenses: Bifocal Low Add, Bifocal Moderate Add, and Trifocal
    Madrid-Costa, David
    Ruiz-Alcocer, Javier
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (11) : 749 - +
  • [14] Functional outcomes after bilateral implantation of apodized diffractive aspheric acrylic intraocular lenses with a+3.0 or+4.0 diopter addition power Randomized multicenter clinical study
    Maxwell, W. Andrew
    Cionni, Robert J.
    Lehmann, Robert P.
    Modi, Satish S.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12) : 2054 - 2061
  • [15] In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: Impact of tilt and decentration
    Montes-Mico, Robert
    Lopez-Gil, Norberto
    Perez-Vives, Cari
    Bonaque, Sergio
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09) : 1657 - 1663
  • [16] Analysis of the possible benefits of aspheric intraocular lenses: Review of the literature
    Montes-Mico, Robert
    Ferrer-Blasco, Teresa
    Cervino, Alejandro
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 172 - 181
  • [17] Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens
    Munoz, Gonzalo
    Albarran-Diego, Cesar
    Ferrer-Blasco, Teresa
    Sakla, Hani E.
    Garcia-Lazaro, Santiago
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 2043 - 2052
  • [18] STANDARDIZED METHODS FOR ASSESSING THE IMAGING QUALITY OF INTRAOCULAR LENSES
    NORRBY, NES
    [J]. APPLIED OPTICS, 1995, 34 (31): : 7327 - 7333
  • [19] Comparison of Two Multifocal Intraocular Lens Designs That Differ Only in Near Add
    Pedrotti, Emilio
    Mastropasqua, Rodolfo
    Passilongo, Mattia
    Parisi, Graziella
    Marchesoni, Ivan
    Marchini, Giorgio
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 755 - 761
  • [20] In Vitro Strehl Ratios with Spherical, Aberration-Free, Average, and Customized Spherical Aberration-Correcting Intraocular Lenses
    Pieh, Stefan
    Fiala, Werner
    Malz, Andre
    Stork, Wilhelm
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (03) : 1264 - 1270