In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony

被引:61
作者
Dominguez-Vicent, Alberto [1 ,2 ]
Juan Esteve-Taboada, Jose [1 ]
Del Aguila-Carrasco, Antonio J. [1 ]
Ferrer-Blasco, Teresa [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp GIO, Valencia, Spain
[2] Univ Valencia, Dept Opt, C Dr Moliner 50, E-46100 Burjassot, Spain
关键词
Multifocal intraocular lens; In vitro measurements; Extended depth of focus; Optical quality; MODULATION TRANSFER-FUNCTION; INTRAOCULAR-LENS DESIGNS; BILATERAL IMPLANTATION; VISUAL FUNCTION; PATIENT SATISFACTION; FUNCTIONAL OUTCOMES; IMAGE QUALITY; PERFORMANCE; TILT; SIZE;
D O I
10.1007/s00417-015-3240-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the optical quality between two intraocular lenses (IOLs): the Mini WELL Ready progressive multifocal (SIFI Medtech, Catania, Italy), and the TECNIS Symfony (Abbott Laboratories, Illinois, USA), which both provide a continuous range of vision from far to near positions. The in vitro optical quality of each lens was assessed with an instrument conceived for measuring the modulation transfer function (MTF). The optical quality of each lens was described in terms of MTF, through-focus MTF, defocus tolerance, pupil dependence, and Strehl ratio MTF. These metrics were assessed for the best lens far focus, and at four vergences (from -1.5 to -3.0 D in 0.5-D steps), at 3.0 and 4.5 mm apertures. The through-focus curves of each lens showed two main areas: one corresponding to far-distance vision, and another to intermediate- and near-distance vision. Both lenses showed similar MTF curves and Strehl ratio values at both apertures. The optical quality of both lenses slightly decreased with the aperture for all vergences. Nevertheless, the quality of the progressive multifocal lens increased with the aperture at far-distance vision. This lens also showed the largest defocus tolerance at near-distance vision for both apertures. The results obtained in the present study suggest that both designs might enlarge the depth of focus. Whereas, the Mini WELL Ready showed better optical quality than the TECNIS Symfony at far vision with 4.5 mm aperture, and larger defocus tolerance than the diffractive lens at near-distance vision.
引用
收藏
页码:1387 / 1397
页数:11
相关论文
共 27 条
  • [1] Intermediate visual function with different multifocal intraocular lens models
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Puchades, Cristina
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) : 733 - 739
  • [2] Visual function after implantation of an aspheric bifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Amhaz, Hussein
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) : 885 - 892
  • [3] [Anonymous], 2014, IDFA 2014 Progress Report: Making a Difference for Dairy, P1
  • [4] Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs
    Artigas, Jose M.
    Menezo, Jose L.
    Peris, Cristina
    Felipe, Adelina
    Diaz-Llopis, Manuel
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) : 2111 - 2117
  • [5] A qualitative investigation of visual tasks with which to assess distance-specific visual function
    Atkinson, Mark J.
    Tally, Steven
    Heichel, Chris W.
    Kozak, Igor
    Leich, Jennifer
    Levack, Ashley
    [J]. QUALITY OF LIFE RESEARCH, 2013, 22 (02) : 437 - 453
  • [6] Optical bench performance of AcrySof((R)) IQ ReSTOR (R), AT LISA((R)) tri, and FineVision((R)) intraocular lenses
    Carson, Daniel
    Hill, Warren E.
    Hong, Xin
    Karakelle, Mutlu
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 2105 - 2113
  • [7] Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye
    Eppig, Timo
    Scholz, Katja
    Loeffler, Andre
    Messner, Arthur
    Langenbucher, Achim
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (06) : 1091 - 1100
  • [8] Correlation between optics quality of multifocal intraocular lenses and visual acuity Tolerance to modulation transfer function decay
    Felipe, Adelina
    Pastor, Francisco
    Artigas, Jose M.
    Diez-Ajenjo, Amparo
    Gene, Andres
    Menezo, Jose L.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) : 557 - 562
  • [9] Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench
    Gatinel, Damien
    Houbrechts, Yvette
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) : 1093 - 1099
  • [10] International Diabetes Federation, 2006, The IDF consensus worldwide definition of the metabolic syndrome, DOI DOI 10.1159/000282084