Polymerization of resin composite restorative materials: exposure reciprocity

被引:120
作者
Musanje, L [1 ]
Darvell, BW [1 ]
机构
[1] Univ Hong Kong, Prince Philip Dent Hosp, Fac Dent, Hong Kong, Hong Kong, Peoples R China
关键词
filled resin composite restorative materials; irradiance; irradiation time; exposure; reciprocity; strength; modulus of elasticity;
D O I
10.1016/S0109-5641(02)00101-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To examine whether there is reciprocity between irradiation time and irradiance with regard to the mechanical properties of filled, resin composite restorative materials (RCs). Methods. Four visible light-cured RCs, all of shade A3, were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein), Filtek Z250 (FZ) (3M, St Paul, MN, USA) and Prodigy condensable (PR) (Kerr, Orange, CA, USA). Bar specimens (1.0 x 1.5 x 16.0 mm(3)) were cured at irradiances (I) ranging from 25 - 1500 mW/cm(2) and irradiation times (t) of 1-3000 s. Six specimens at 250 combinations of t and I were prepared and stored in artificial saliva of pH 6, at 37 degreesC for 7 d before performing three-point bend tests for flexural strength (F), flexural modulus (E) and total energy to failure (W). Contour plots of property value vs. t and I on log scales were prepared. Results. The contour plots showed three regions: unset at low I-t, a plateau corresponding to more or less full property development, and connecting ramp. The boundary between the plateau and the ramp suggests the minimum acceptable exposure. No practical lower limit to irradiance was detected, but there may be no benefit from increasing I beyond about 1000 MW/cm(2). The slopes of the contours in the log-log plots provided a test of the hypothesis of reciprocity. These slopes were similar to - 1.5 for HR, TC and PR; and similar to - 1 for FZ, compared with the expected value of - 1. The general hypothesis therefore fails. The existence of localized maxima in property values is further evidence of that failure, even for FZ. Significance. Dentists may use any lamp, including LED sources, and attain satisfactory results providing irradiation time is long enough. Manufacturers ought to supply a graph indicating the minimum acceptable exposure for each product for specified curing lamps. Calculations based on total energy delivered to guide irradiation protocols are invalid and do not recognize product behavior. (C) 2003 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:531 / 541
页数:11
相关论文
共 34 条
[1]   EVALUATING INTENSITY OUTPUT OF CURING LIGHTS IN PRIVATE DENTAL OFFICES [J].
BARGHI, N ;
BERRY, T ;
HATTON, C .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1994, 125 (07) :992-996
[2]  
BAYNE SC, 1994, ART SCI OPERATIVE DE, P206
[3]   STABILITY OF RADICALS IN CURED COMPOSITE-MATERIALS [J].
BURTSCHER, P .
DENTAL MATERIALS, 1993, 9 (04) :218-221
[4]  
CAUGHMAN WF, 1995, J AM DENT ASSOC, V126, P1280
[5]   POLYMERIZATION KINETICS OF RESIN-BASED RESTORATIVE MATERIALS [J].
COOK, WD ;
STANDISH, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (02) :275-282
[6]  
Friedman J, 1989, J Esthet Dent, V1, P189, DOI 10.1111/j.1708-8240.1989.tb00500.x
[7]  
HEAP RD, 1969, FLEXURAL TESTING PLA
[8]   Comparison between a plasma arc light source and conventional halogen curing units regarding flexural strength, modulus, and hardness of photoactivated resin composites. [J].
Hofmann N. ;
Hugo B. ;
Schubert K. ;
Klaiber B. .
Clinical Oral Investigations, 2000, 4 (3) :140-147
[9]   Depth of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs) [J].
Jandt, KD ;
Mills, RW ;
Blackwell, GB ;
Ashworth, SH .
DENTAL MATERIALS, 2000, 16 (01) :41-47
[10]  
Kanca J, 1999, AM J DENT, V12, P107