Corrosion-induced reduction in compressive strength of self-compacting concretes containing mineral admixtures

被引:29
作者
Ghanooni-Bagha, M. [1 ]
Shayanfar, M. A. [2 ]
Shirzadi-Javid, A. A. [3 ]
Ziaadiny, H. [4 ]
机构
[1] Islamic Azad Univ, East Tehran Branch, Dept Civil Engn, Tehran, Iran
[2] Iran Univ Sci & Technol, Ctr Excellence Fundamental Studies Struct Engn, POB 16765-163, Tehran, Iran
[3] Iran Univ Sci & Technol, Sch Civil Engn, POB 16765-163, Tehran, Iran
[4] Vali e Asr Univ Rafsanjan, Dept Civil Engn, Rafsanjan, Iran
关键词
Reinforced concrete structures; Rebar corrosion; Corrosion cracking; Compressive strength; Accelerated corrosion test; Self-compacting concrete; REINFORCED-CONCRETE; STEEL REINFORCEMENT; RC BEAMS; PERFORMANCE; CRACKING; SUBJECT; BRIDGE; BOND;
D O I
10.1016/j.conbuildmat.2016.03.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, the corrosion resistance of square and rectangular concrete cubes is evaluated and the correlation between the corrosion and the concrete compressive strength reduction is examined. Concrete specimens with different admixtures were prepared and exposed to accelerated corrosion, and the compressive-strength reduction coefficients of the Vecchio-Collins relation were also modified. The concrete-covering effect on compressive-strength reduction was also investigated by applying corrosion to rectangular block samples. The test results revealed that corrosion resistance and compressive strength are not always directly related. The mixtures with lower compressive strength and mineral admixtures demonstrated the highest corrosion resistance. By maintaining and protecting structures, or by increasing the curing duration from 1 to 3 months, it is possible to increase the time before structural corrosion by 2-4 times. When crack width was increased by about 1 mm (which reflects 7-12% corrosion in rebars) compressive strength dropped by about 20%. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 29 条
[1]  
Al-Ostaz A, 2004, DIAGNOSTIC EVALUATIO
[2]   Structural performance of corroded RC beams repaired with CFRP sheets [J].
Al-Saidy, A. H. ;
Al-Harthy, A. S. ;
Al-Jabri, K. S. ;
Abdul-Halim, M. ;
Al-Shidi, N. M. .
COMPOSITE STRUCTURES, 2010, 92 (08) :1931-1938
[3]  
[Anonymous], 2011, ACI STRUCT J, V108
[4]  
[Anonymous], 2003, STANDARD SPECIFICATI
[5]  
B.S. EN, 2002, 12390-3 Testing hardened concrete-Part 3: compressive strength of test specimens
[6]  
Bertolini L., 2013, Corrosion of Steel in Concrete: Prevention,Diagnosis, Repair
[7]   CORROSION OF STEEL IN CONCRETE WITH AND WITHOUT SILICA FUME [J].
CAO, HT ;
SIRIVIVATNANON, V .
CEMENT AND CONCRETE RESEARCH, 1991, 21 (2-3) :316-324
[8]  
CAPE M, 1999, THESIS CHALMERS U TE, P133
[9]   Structural assessment of corroded reinforced concrete beams: Modeling guidelines [J].
Coronelli, D ;
Gambarova, P .
JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (08) :1214-1224
[10]   Bond behaviour of corroded reinforcing steel bars in concrete [J].
Fang, Congqi ;
Lundgren, Karin ;
Plos, Mario ;
Gylltoft, Kent .
CEMENT AND CONCRETE RESEARCH, 2006, 36 (10) :1931-1938