Retrospective longitudinal assessment of ultrasound gout lesions using the OMERACT semi-quantitative scoring system

被引:8
作者
Christiansen, Sara Nysom [1 ]
Ostergaard, Mikkel [1 ,2 ]
Slot, Ole [1 ]
Fana, Viktoria [1 ]
Terslev, Lene [1 ,2 ]
机构
[1] Rigshosp, Copenhagen Ctr Arthrit Res, Ctr Rheumatol & Spine Dis, Ctr Head & Orthoped, Glostrup, Denmark
[2] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
关键词
ultrasound; gout; monitoring; longitudinal validity; OMERACT; double contour; tophus; aggregates; URATE CRYSTAL DEPOSITION; DELPHI PROCESS; DIAGNOSIS; MANAGEMENT; CONSENSUS; BURDEN; RISK;
D O I
10.1093/rheumatology/keac179
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The objectives of this study were (i) to evaluate the responsiveness of gout-specific US lesions representing urate deposition in patients receiving treat-to-target urate-lowering therapy using a binary and the OMERACT-defined semi-quantitative scoring systems; (ii) to determine the most responsive US measure for urate deposition and the optimal joint/tendon set for monitoring this. Methods US (28 joints, 14 tendons) was performed in microscopically verified gout patients initiating/increasing urate-lowering therapy and repeated after 6 and 12 months. Static images/videos of pathologies were stored and scored binarily and semi-quantitatively for tophus, double contour sign (DC) and aggregates. Lesion scores were calculated at patient level, as were combined crystal sum scores. Responsiveness of lesions-scored binarily and semi-quantitatively-was calculated at both patient and joint/tendon levels. Results Sixty-three patients underwent longitudinal evaluation. The static images/videos assessed retrospectively showed statistically significant decreases in tophus and DC, when scored binarily and semi-quantitatively, whereas aggregates were almost unchanged during follow-up. The responsiveness of the semi-quantitative tophus and DC sum scores were markedly higher than when using binary scoring. The most responsive measure for urate deposition was a combined semi-quantitative tophus-DC-sum score. A feasible joint/tendon set for monitoring included knee and first-second MTP joints and peroneus and distal patella tendons (all bilateral), representing the most prevalent and responsive sites. Conclusion The OMERACT consensus-based semi-quantitative US gout scoring system showed longitudinal validity with both tophus and DC being highly responsive to treatment when assessed in static images/videos. A responsive US measure for urate deposition and a feasible joint/tendon set for monitoring were proposed and may prove valuable in future longitudinal studies.
引用
收藏
页码:4711 / 4721
页数:11
相关论文
共 26 条
[1]   Guidelines for musculoskeletal ultrasound in rheumatology [J].
Backhaus, M ;
Burmester, GR ;
Gerber, T ;
Grassi, W ;
Machold, KP ;
Swen, WA ;
Wakefield, RJ ;
Manger, B .
ANNALS OF THE RHEUMATIC DISEASES, 2001, 60 (07) :641-649
[2]   Ultrasonographic detection of double contour sign and hyperechoic aggregates for diagnosis of gout: two sites examination is as good as six sites examination [J].
Bhadu, Danveer ;
Das, Siddharth K. ;
Wakhlu, Archana ;
Dhakad, Urmila ;
Sharma, Meha .
INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2018, 21 (02) :523-531
[3]   OMERACT Definitions for Ultrasonographic Pathologies and Elementary Lesions of Rheumatic Disorders 15 Years On [J].
Bruyn, George A. ;
Iagnocco, Annamaria ;
Naredo, Esperanza ;
Balint, Peter V. ;
Gutierrez, Marwin ;
Hammer, Hilde B. ;
Collado, Paz ;
Filippou, Georgios ;
Schmidt, Wolfgang A. ;
Jousse-Joulin, Sandrine ;
Mandl, Peter ;
Conaghan, Philip G. ;
Wakefield, Richard J. ;
Keen, Helen I. ;
Terslev, Lene ;
D'Agostino, Maria Antonietta ;
Aydin, Sibel ;
Backhaus, Marina ;
Bachta, Artur ;
Chary-Valckenaere, Isabelle ;
Chrysidis, Stavros ;
Damjanov, Nemanja ;
Dasgupta, Bhaskar ;
Filippucci, Emilio ;
Gandjbachkh, Frederique ;
Filer, Andrew ;
Finzel, Stephanie ;
Hanova, Petra ;
Hocevar, Alojzija ;
Diaz, Cristina Hernandez ;
Ikeda, Kei ;
Inanc, Nevsun ;
Kaeley, Gurjit ;
Kortekaas, Marion ;
Lee, Gavin ;
Loeuille, Damien ;
Manzoni, Silvia Magni ;
Malattia, Clara ;
Micu, Mihaela ;
Moller, Ingrid ;
Pineda, Carlos ;
Ravagnani, Viviana ;
Richards, Bethan ;
Roth, Johannes ;
Schafer, Valentin ;
delle Sedie, Andrea ;
Skzudlarek, Marcin ;
Tzaribachev, Nicolas ;
Sahbudin, Ilfita ;
Stoenoiu, Maria .
JOURNAL OF RHEUMATOLOGY, 2019, 46 (10) :1388-1393
[4]   Independent impact of gout on mortality and risk for coronary heart disease [J].
Choi, Hyon K. ;
Curhan, Gary .
CIRCULATION, 2007, 116 (08) :894-900
[5]   Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise [J].
Christiansen, Sara Nysom ;
Filippou, Georgios ;
Scire, Carlo Alberto ;
Balint, Peter, V ;
Bruyn, George A. W. ;
Dalbeth, Nicola ;
Dejaco, Christian ;
Delle Sedie, Andrea ;
Filippucci, Emilio ;
Hammer, Hilde B. ;
Iagnocco, Annamaria ;
Keen, Helen, I ;
Kissin, Eugene Y. ;
Koski, Juhani ;
Mandl, Peter ;
Martin, Julia ;
De Miguel, Eugenio ;
Moller, Ingrid ;
Naredo, Esperanza ;
Pineda, Carlos ;
Schmidt, Wolfgang A. ;
Stewart, Sarah ;
D'Agostino, Maria Antonietta ;
Terslev, Lene .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 2021, 51 (03) :644-649
[6]   Ultrasound for the diagnosis of gout-the value of gout lesions as defined by the Outcome Measures in Rheumatology ultrasound group [J].
Christiansen, Sara Nysom ;
Ostergaard, Mikkel ;
Slot, Ole ;
Fana, Viktoria ;
Terslev, Lene .
RHEUMATOLOGY, 2021, 60 (01) :239-249
[7]   Assessing the sensitivity to change of the OMERACT ultrasound structural gout lesions during urate-lowering therapy [J].
Christiansen, Sara Nysom ;
Ostergaard, Mikkel ;
Slot, Ole ;
Keen, Helen ;
Bruyn, George A. W. ;
D'Agostino, Maria Antonietta ;
Terslev, Lene .
RMD OPEN, 2020, 6 (01)
[8]   Gout [J].
Dalbeth, Nicola ;
Merriman, Tony R. ;
Stamp, Lisa K. .
LANCET, 2016, 388 (10055) :2039-2052
[9]   Ultrasound evaluation in follow-up of urate-lowering therapy in gout: the USEFUL study [J].
Ebstein, Esther ;
Forien, Marine ;
Norkuviene, Eleonora ;
Richette, Pascal ;
Mouterde, Gael ;
Daien, Claire ;
Ea, Hang-Korng ;
Briere, Claire ;
Liote, Frederic ;
Petraitis, Mykolas ;
Bardin, Thomas ;
Ora, Jeremy ;
Dieude, Philippe ;
Ottaviani, Sebastien .
RHEUMATOLOGY, 2019, 58 (03) :410-417
[10]   International Consensus for ultrasound lesions in gout: results of Delphi process and web-reliability exercise [J].
Gutierrez, Marwin ;
Schmidt, Wolfgang A. ;
Thiele, Ralf G. ;
Keen, Helen I. ;
Kaeley, Gurjit S. ;
Naredo, Esperanza ;
Iagnocco, Annamaria ;
Bruyn, George A. ;
Balint, Peter V. ;
Filippucci, Emilio ;
Mandl, Peter ;
Kane, David ;
Pineda, Carlos ;
Delle Sedie, Andrea ;
Hammer, Hilde Berner ;
Christensen, Robin ;
D'Agostino, Maria Antonietta ;
Terslev, Lene .
RHEUMATOLOGY, 2015, 54 (10) :1797-1805