Biomechanical evaluation of magnesium plates for management of mandibular angle fracture

被引:2
作者
Mohammed, Altaib Abd Al Razik [1 ]
机构
[1] South Valley Univ, Fac Oral & Dent Med, Dept Oral & Maxillofacial Surg, Qena Governorate, Egypt
关键词
Biomechanical; Magnesium; Mandible; Angle fracture; IN-VITRO; FIXATION; BODY; EPIDEMIOLOGY; CORROSION; PATTERNS; IMPLANTS; ALLOYS;
D O I
10.1016/j.bjoms.2021.11.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to evaluate the efficacy of magnesium plates for the management of fractures of the mandibular angle. Fresh sheep hemimandibles were divided into 7 groups and a biomechanical cantilever bending test was used for the groups: Group 1 included fractured hemimandibles fixed at the angle with a single 1mm magnesium miniplate; Group 2 had fixation with a 1mm double magnesium miniplate; Group 3 used a 2mm thick single magnesium miniplate; Group 4 used double 2mm magnesium plates; Group 5 each had a single 1mm thick titanium plate; Group 6 used 1mm thick double titanium plates; and Group 7 comprised intact hemimandibles. Each group was tested using universal testing machine yield loads; yield displacements and stiffness were compared using one way analysis of variance (ANOVA) Group 1 (1mm single magnesium plate) and Group 2 (1mm double magnesium plates) showed lower stability than other groups, while the 2mm magnesium plate showed stability similar to the corresponding 1mm titanium plate. Pure magnesium has good mechanical properties and when it is designed properly it can be used for the management of mandibular fracture.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 28 条
[1]   Epidemiology of Facial Fracture Injuries [J].
Allareddy, Veerasathpurush ;
Allareddy, Veerajalandhar ;
Nalliah, Ramesh P. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (10) :2613-2618
[2]  
[Anonymous], 2003, DESIGNATION F382 REA
[3]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[4]   Hardware removal: Indications and expectations [J].
Busam, ML ;
Esther, RJ ;
Obremskey, WT .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (02) :113-120
[5]   In vitro and in vivo corrosion, cytocompatibility and mechanical properties of biodegradable Mg-Y-Ca-Zr alloys as implant materials [J].
Chou, Da-Tren ;
Hong, Daeho ;
Saha, Partha ;
Ferrero, Jordan ;
Lee, Boeun ;
Tan, Zongqing ;
Dong, Zhongyun ;
Kumta, Prashant N. .
ACTA BIOMATERIALIA, 2013, 9 (10) :8518-8533
[6]   A Prospective Study of 3 Treatment Methods for Isolated Fractures of the Mandibular Angle [J].
Ellis, Edward, III .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (11) :2743-2754
[7]   Biomechanical evaluation of malleable noncompression miniplates in mandibular angle fractures: an experimental study [J].
Esen, Alparslan ;
Dolanmaz, Dogan ;
Tuz, Hakan Hifzi .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2012, 50 (05) :E65-E68
[8]   Surgeons' beliefs and perceptions about removal of orthopaedic implants [J].
Hanson, Beate ;
van der Werken, Chris ;
Stengel, Dirk .
BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)
[9]   Corrosion of metal orthopaedic implants [J].
Jacobs, JJ ;
Gilbert, JL ;
Urban, RM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (02) :268-282
[10]  
Lakshmi G., 2012, ANN ESSENCE DENT, V4, P104