Ultrasonography in orbital floor fractures: An alternative to computed tomography?

被引:13
作者
Klinger, M
Danter, J
Siegert, R
机构
关键词
blow-out fracture; ultrasound; B-scan; orbital floor fracture; diagnosis;
D O I
10.1055/s-2007-997569
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Plain radiography of the paranasal sinuses (Water's view) may fail to demonstrate typical signs of orbital floor fractures. To resolve questionable cases, computed tomography (CI) is performed. B-mode ultrasonography (US) is investigated concerning its reliability and as a possible alternative to CT. The replacement of standard radiological techniques in primary evaluation will be discussed. Methods: A skull was used to assess the visualization of the bony floor in the ultrasound-technique. Fifteen patients with suspected fractures of the orbital floor were investigated with plain radiographs, ultrasound of both orbits in dosed-eyelid technique, and CT scans. The findings were compared, Results: Thirteen patients were found to have apparent fractures in CT scans. These fractures were also diagnosed on ultrasound. In three patients, ultrasonographic localization was unprecise. These fractures were located behind the lower orbital rim or far posteriorly. Plain radiographs showed positive Fracture signs only in five patients, Localization was not possible, The application of the ultrasound probe was well tolerated. Conclusions: B-mode ultrasonography is a valuable and inexpensive technique to visualize orbital floor fractures, it should be employed in primary evaluation in patients with suspected isolated orbital floor fractures prior to taking plain radiographs of the paranasal sinuses. Computed tomography should be used in suspected complex fractures and questionable orbital fractures.
引用
收藏
页码:242 / 246
页数:5
相关论文
共 50 条
[41]   Computed tomography of suspected scaphoid fractures [J].
Adey, Lauren ;
Souer, J. Sebastiaan ;
Lozano-Calderon, Santiago ;
Palmer, William ;
Lee, Sang-Gil ;
Ring, David .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (01) :61-66
[42]   "Trap Door" Orbital Floor Fractures in Adults: Are They Different from Pediatric Fractures? [J].
Al-Qattan, Mohammad M. ;
Al-Qattan, Yousef M. .
PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2021, 9 (04) :E3537
[43]   Interobserver variation of the sonographic diagnosis of orbital floor fractures and fractures of the infraorbital margin [J].
Jank S. ;
Deibl M. ;
Strobl H. ;
Oberrauch A. ;
Nicasi A. ;
Missmann M. ;
Bodner G. .
Mund-, Kiefer- und Gesichtschirurgie, 2004, 8 (6) :337-343
[44]   Lung Aeration in COVID-19 Pneumonia by Ultrasonography and Computed Tomography [J].
Kalkanis, Alexandros ;
Schepers, Christophe ;
Louvaris, Zafeiris ;
Godinas, Laurent ;
Wauters, Els ;
Testelmans, Dries ;
Lorent, Natalie ;
Van Mol, Pierre ;
Wauters, Joost ;
De Wever, Walter ;
Dooms, Christophe .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (10)
[45]   The gap between ultrasonography and computed tomography in measuring the size of urinary calculi [J].
Alahmadi, Ahmed Eid ;
Aljuhani, Fawaz Mobasher ;
Alshoabi, Sultan Abdulwadoud ;
Aloufi, Khalid M. ;
Alsharif, Walaa M. ;
Alamri, Abdulrahman M. .
JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (09) :4925-4928
[46]   Monocular Diplopia and Nondisplaced Inferior Rectus Muscle on Computed Tomography in a Pediatric Pure Orbital-Floor Fracture [J].
Joganathan, Varajini ;
Gupta, Deepak ;
Beigi, Bijan .
JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) :1832-1833
[47]   Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR [J].
Widmann, G. ;
Dalla Torre, D. ;
Hoermann, R. ;
Schullian, P. ;
Gassner, E. M. ;
Bale, R. ;
Puelacher, W. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (04) :441-446
[48]   Comparison of Panorama Ultrasonography, Conventional B-Mode Ultrasonography, and Computed Tomography for Measuring Liver Size [J].
Borchert, D. ;
Schuler, A. ;
Muche, R. ;
Haenle, M. M. ;
Akinli, A. S. ;
Arnold, F. ;
Kratzer, W. ;
Pauls, S. .
ULTRASCHALL IN DER MEDIZIN, 2010, 31 (01) :31-36
[49]   Ultrasonography can be more informative than computed tomography for diagnosing radial head fractures: An illustrative case series [J].
Scholl, Eckehart ;
Jakob, Marcel ;
Vach, Werner .
ULTRASCHALL IN DER MEDIZIN, 2024,
[50]   Mechanical resistance of the periorbita and the orbital floor complex-are isolated orbital floor fractures only a soft tissue problem? [J].
Birkenfeld, F. ;
Behrens, E. ;
Floerke, C. ;
Rohnen, M. ;
Wieker, H. ;
Kern, M. ;
Lucius, R. ;
Wiltfang, J. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (03) :279-283