Ultrasonography in orbital floor fractures: An alternative to computed tomography?

被引:13
作者
Klinger, M
Danter, J
Siegert, R
机构
关键词
blow-out fracture; ultrasound; B-scan; orbital floor fracture; diagnosis;
D O I
10.1055/s-2007-997569
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: Plain radiography of the paranasal sinuses (Water's view) may fail to demonstrate typical signs of orbital floor fractures. To resolve questionable cases, computed tomography (CI) is performed. B-mode ultrasonography (US) is investigated concerning its reliability and as a possible alternative to CT. The replacement of standard radiological techniques in primary evaluation will be discussed. Methods: A skull was used to assess the visualization of the bony floor in the ultrasound-technique. Fifteen patients with suspected fractures of the orbital floor were investigated with plain radiographs, ultrasound of both orbits in dosed-eyelid technique, and CT scans. The findings were compared, Results: Thirteen patients were found to have apparent fractures in CT scans. These fractures were also diagnosed on ultrasound. In three patients, ultrasonographic localization was unprecise. These fractures were located behind the lower orbital rim or far posteriorly. Plain radiographs showed positive Fracture signs only in five patients, Localization was not possible, The application of the ultrasound probe was well tolerated. Conclusions: B-mode ultrasonography is a valuable and inexpensive technique to visualize orbital floor fractures, it should be employed in primary evaluation in patients with suspected isolated orbital floor fractures prior to taking plain radiographs of the paranasal sinuses. Computed tomography should be used in suspected complex fractures and questionable orbital fractures.
引用
收藏
页码:242 / 246
页数:5
相关论文
共 15 条
[1]   STANDARDIZED ECHOGRAPHY OF THE EYE AND ORBIT [J].
BYRNE, SF .
NEURORADIOLOGY, 1986, 28 (5-6) :618-640
[2]   EYE MUSCLE IMBALANCE COMPLICATING ORBITAL FLOOR FRACTURES [J].
COLE, HG ;
SMITH, B .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1963, 55 (05) :930-&
[4]   THE ROLE OF ORBITAL ULTRASOUND IN THE DIAGNOSIS OF ORBITAL FRACTURES [J].
FORREST, CR ;
LATA, AC ;
MARCUZZI, DW ;
BAILEY, MH .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (01) :28-34
[5]  
GROSSNIKLAUS H, 1983, ANN OPHTHALMOL, V15, P904
[6]  
Kley W, 1968, Arch Klin Exp Ohren Nasen Kehlkopfheilkd, V191, P1, DOI 10.1007/BF00445730
[7]   WHEN IS SURGERY INDICATED FOR BLOW-OUT AND MID-FACE FRACTURES [J].
KOCH, U ;
REINERT, S ;
HARTWIG, H .
LARYNGOLOGIE RHINOLOGIE OTOLOGIE VEREINIGT MIT MONATSSCHRIFT FUR OHRENHEILKUNDE, 1985, 64 (08) :388-393
[8]  
Lentrodt J, 1991, Fortschr Kiefer Gesichtschir, V36, P184
[9]  
LEVINE RA, 1987, RADIOL CLIN N AM, V25, P447
[10]  
Mann W, 1976, Laryngol Rhinol Otol (Stuttg), V55, P48