Systematic errors in respiratory gating due to intrafraction deformations of the liver

被引:96
作者
von Siebenthal, Martin [1 ]
Szekely, Gabor
Lomax, Antony J.
Cattin, Philippe C.
机构
[1] ETH, Comp Vis Lab, CH-8092 Zurich, Switzerland
[2] Paul Scherrer Inst, Div Radiat Med, CH-5232 Villigen, Switzerland
关键词
4DMRI; respiratory liver motion; respiratory gating; radiation therapy;
D O I
10.1118/1.2767053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article shows the limitations of respiratory gating due to intrafraction deformations of the right liver lobe. The variability of organ shape and motion over tens of minutes was taken into account for this evaluation, which closes the gap between short-term analysis of a few regular cycles, as it is possible with 4DCT, and long-term analysis of interfraction motion. Time resolved MR volumes (41) MR sequences) were reconstructed for 12 volunteers and subsequent non-rigid registration provided estimates of the 3D trajectories of points within the liver over time. The full motion during free breathing and its distribution over the liver were quantified and respiratory gating was simulated to determine the gating accuracy for different gating signals, duty cycles, and different intervals between patient setup and treatment. Gating effectively compensated for the respiratory motion within short sequences (3 min), but deformations, mainly in the anterior inferior part (Couinaud segments IVb and V), led to systematic deviations from the setup position of more than 5 min in 7 of 12 subjects after 20 min. We conclude that measurements over a few breathing cycles should not be used as a proof of accurate reproducibility of motion, not even within the same fraction, if it is longer than a few minutes. Although the diaphragm shows the largest magnitude of motion, it should not be used to assess the gating accuracy over the entire liver because the reproducibility is typically much more limited in inferior parts. Simple gating signals, such as the trajectory of skin motion, can detect the exhalation phase, but do not allow for an absolute localization of the complete liver over longer periods because the drift of these signals does not necessarily correlate with the internal drift. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:3620 / 3629
页数:10
相关论文
共 25 条
[11]   Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I - Correlating internal lung motion with skin fiducial motion [J].
Koch, N ;
Liu, HH ;
Starkschall, G ;
Jacobson, M ;
Forster, K ;
Liao, ZX ;
Komaki, R ;
Stevens, CW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05) :1459-1472
[12]   Intrafractional motion during proton beam scanning [J].
Lambert, J ;
Suchowerska, N ;
McKenzie, DR ;
Jackson, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :4853-4862
[13]   Intensity modulation methods for proton radiotherapy [J].
Lomax, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :185-205
[14]   A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing [J].
Low, DA ;
Nystrom, M ;
Kalinin, E ;
Parikh, P ;
Dempsey, JF ;
Bradley, JD ;
Mutic, S ;
Wahab, SH ;
Islam, T ;
Christensen, G ;
Politte, DG ;
Whiting, BR .
MEDICAL PHYSICS, 2003, 30 (06) :1254-1263
[15]  
Mageras G S, 2001, J Appl Clin Med Phys, V2, P191, DOI 10.1120/1.1409235
[16]   4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT [J].
Pan, T ;
Lee, TY ;
Rietzel, E ;
Chen, GTY .
MEDICAL PHYSICS, 2004, 31 (02) :333-340
[17]   THE 200-MEV PROTON THERAPY PROJECT AT THE PAUL-SCHERRER-INSTITUTE - CONCEPTUAL DESIGN AND PRACTICAL REALIZATION [J].
PEDRONI, E ;
BACHER, R ;
BLATTMANN, H ;
BOHRINGER, T ;
CORAY, A ;
LOMAX, A ;
LIN, SX ;
MUNKEL, G ;
SCHEIB, S ;
SCHNEIDER, U ;
TOUROVSKY, A .
MEDICAL PHYSICS, 1995, 22 (01) :37-53
[18]   EFFECTS OF RESPIRATORY MOTION ON DOSE UNIFORMITY WITH A CHARGED-PARTICLE SCANNING METHOD [J].
PHILLIPS, MH ;
PEDRONI, E ;
BLATTMANN, H ;
BOEHRINGER, T ;
CORAY, A ;
SCHEIB, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :223-234
[19]   Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion [J].
Rietzel, E ;
Chen, GTY ;
Choi, NC ;
Willet, CG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1535-1550
[20]   Nonrigid registration using free-form deformations: Application to breast MR images [J].
Rueckert, D ;
Sonoda, LI ;
Hayes, C ;
Hill, DLG ;
Leach, MO ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) :712-721