Three-dimensional facial anatomy evaluation: Reliability of laser scanner consecutive scans procedure in comparison with stereophotogrammetry

被引:36
作者
Gibelli, Daniele [1 ,2 ]
Pucciarelli, Valentina [1 ]
Poppa, Pasquale [2 ]
Cummaudo, Marco [2 ]
Dolci, Claudia [1 ]
Cattaneo, Cristina [2 ]
Sforza, Chiarella [1 ]
机构
[1] Univ Milan, LAFAS, Dipartimento Sci Biomed Salute, Milan, Italy
[2] Univ Milan, Dipartimento Sci Biomed Salute, Lab Antropol & Odontol Forense, LABANOF, Milan, Italy
关键词
Face; Laser scanner; Photogrammetry; Root mean square (RMS); PERSONAL IDENTIFICATION; MORPHOLOGY; ACCURACY; SYSTEMS; IMAGES; REPRODUCIBILITY; ANTHROPOMETRY; PRECISION; LANDMARKS; GENDER;
D O I
10.1016/j.jcms.2018.07.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Laser scanner devices are acquiring a growing importance in facial anatomy. Most studies have analysed facial scans obtained through two simultaneous captures, whereas the same result can be obtained by consecutive three-dimensional (3D) scans. However, this latter procedure has not yet been validated. Fourteen volunteers underwent face image capture through stereophotogrammetry (VECTRA M3) and three consecutive facial scans through a laser scanner (Konica Minolta Vi910). The concordance between 14 linear distances, 12 angles, facial surface area and volume measurements was verified by the Bland-Altman test and calculation of absolute and relative technical errors of measurement (TEM/rTEM). The two facial images obtained by the different devices were then registered to calculate point-to-point distance. Most of linear distances and angles showed a high agreement, with "very good" or "good" rTEMs, ranging between 1.1% and 6.4%. Surface area measurements agreed well between the devices (rTEM: 6.3%), while volumes were poorly comparable (rTEM: 25.8%); the root mean square point-to-point distance was 0.80 mm (SD: 0.41). This study first tested the concordance of measurements on facial images obtained by stereophotogrammetry and consecutive laser scans. Results highlight the reliability of linear distances, angles and surface areas measurements, but discourage volume assessment and registration of surfaces acquired through different devices. (C) 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1807 / 1813
页数:7
相关论文
共 36 条
[1]  
Camison L, 2017, J ORAL MAXILLOFAC SU, P31606
[2]   Personal Identification by the Comparison of Facial Profiles: Testing the Reliability of a High-Resolution 3D-2D Comparison Model [J].
Cattaneo, Cristina ;
Cantatore, Angela ;
Ciaffi, Romina ;
Gibelli, Daniele ;
Cigada, Alfredo ;
De Angelis, Danilo ;
Sala, Remo .
JOURNAL OF FORENSIC SCIENCES, 2012, 57 (01) :182-187
[3]   Laser scanner compared with stereophotogrammetry for measurements of area on nasal plaster casts [J].
Codari, M. ;
Pucciarelli, V. ;
Pisoni, L. ;
Sforza, C. .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (08) :769-770
[4]   Facial thirds-based evaluation of facial asymmetry using stereophotogrammetric devices: Application to facial palsy subjects [J].
Codari, Marina ;
Pucciarelli, Valentina ;
Stangoni, Fabiano ;
Zago, Matteo ;
Tarabbia, Filippo ;
Biglioli, Federico ;
Sforza, Chiarella .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (01) :76-81
[5]   A new computer-assisted technique to aid personal identification [J].
De Angelis, Danilo ;
Sala, Remo ;
Cantatore, Angela ;
Grandi, Marco ;
Cattaneo, Cristina .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2009, 123 (04) :351-356
[6]   Accuracy and Reproducibility of a 3-Dimensional Stereophotogrammetric Imaging System [J].
de Menezes, Marcio ;
Rosati, Riccardo ;
Ferrario, Virgilio F. ;
Sforza, Cbiarella .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (09) :2129-2135
[7]   Three-dimensional analysis of facial shape and symmetry in twins using laser surface scanning [J].
Djordjevic, J. ;
Jadallah, M. ;
Zhurov, A. I. ;
Toma, A. M. ;
Richmond, S. .
ORTHODONTICS & CRANIOFACIAL RESEARCH, 2013, 16 (03) :146-160
[8]   Evaluation of Precision and Accuracy Assessment of Different 3-D Surface Imaging Systems for Biomedical Purposes [J].
Eder, Maximilian ;
Brockmann, Gernot ;
Zimmermann, Alexander ;
Papadopoulos, Moschos A. ;
Schwenzer-Zimmerer, Katja ;
Zeilhofer, Hans Florian ;
Sader, Robert ;
Papadopulos, Nikolaos A. ;
Kovacs, Laszlo .
JOURNAL OF DIGITAL IMAGING, 2013, 26 (02) :163-172
[9]   Anthropometric determination of craniofacial morphology [J].
Farkas, LG ;
Deutsch, CK .
AMERICAN JOURNAL OF MEDICAL GENETICS, 1996, 65 (01) :1-4
[10]   Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems [J].
Fourie, Zacharias ;
Damstra, Janalt ;
Gerrits, Peter O. ;
Ren, Yijin .
FORENSIC SCIENCE INTERNATIONAL, 2011, 207 (1-3) :127-134