The Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation

被引:4
作者
Saldanha, Ramya L. [1 ]
Urdaneta, Morgan E. [2 ]
Otto, Kevin J. [1 ,2 ,3 ,4 ,5 ]
机构
[1] Univ Florida, J Crayton Pruitt Family Dept Biomed Engn, Gainesville, FL 32611 USA
[2] Univ Florida, Dept Neurosci, Gainesville, FL 32610 USA
[3] Univ Florida, Dept Mat Sci & Engn, Gainesville, FL 32611 USA
[4] Univ Florida, Dept Neurol, Gainesville, FL 32611 USA
[5] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
brain-machine interfaces; neuroprosthetics; intracortical microelectrodes; microstimulation; electrode design; INTERFACES; RESPONSES; DESIGN;
D O I
10.3389/fnins.2021.712578
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Intracortical microelectrodes are neuroprosthetic devices used in brain-machine interfaces to both record and stimulate neural activity in the brain. These technologies have been improved by advances in microfabrication, which have led to the creation of subcellular and high-density microelectrodes. The greater number of independent stimulation channels in these devices allows for improved neuromodulation selectivity, compared to single-site microelectrodes. Elements of electrode design such as electrode-site placement can influence the long-term performance of neuroprostheses. Previous studies have shown that electrode-sites placed on the edge of a planar microelectrode have greater chronic recording functionality than sites placed in the center. However, the effect of electrode-site placement on long-term intracortical microstimulation (ICMS) is still unknown. Here, we show that, in rats chronically implanted with custom-made planar silicon microelectrodes, electrode-sites on the tip of the device outperformed those on both the edge and center in terms of the effect per charge delivered, though there is still a slight advantage to using edge sites over center sites for ICMS. Longitudinal analysis of ICMS detection thresholds over a 16-week period revealed that while all sites followed a similar trend over time, the tip and edge sites consistently elicited the behavioral response with less charge compared to center sites. Furthermore, we quantified channel activity over time and found that edge sites remained more active than center sites over time, though the rate of decay of active sites for center and edge sites was comparable. Our results demonstrate that electrode-site placement plays an important role in the long-term stability of intracortical microstimulation and could be a potential factor to consider in the design of future intracortical electrodes.y
引用
收藏
页数:8
相关论文
共 25 条
  • [1] Biophysically realistic neuron models for simulation of cortical stimulation
    Aberra, Aman S.
    Peterchev, Angel, V
    Grill, Warren M.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2018, 15 (06)
  • [2] VISUAL SENSATIONS PRODUCED BY INTRACORTICAL MICROSTIMULATION OF THE HUMAN OCCIPITAL CORTEX
    BAK, M
    GIRVIN, JP
    HAMBRECHT, FT
    KUFTA, CV
    LOEB, GE
    SCHMIDT, EM
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) : 257 - 259
  • [3] Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
    Bensmaia, Sliman J.
    Miller, Lee E.
    [J]. NATURE REVIEWS NEUROSCIENCE, 2014, 15 (05) : 313 - 325
  • [4] Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
    Biran, R
    Martin, DC
    Tresco, PA
    [J]. EXPERIMENTAL NEUROLOGY, 2005, 195 (01) : 115 - 126
  • [5] Role of electrode design on the volume of tissue activated during deep brain stimulation
    Butson, Christopher R.
    McIntyre, Cameron C.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2006, 3 (01) : 1 - 8
  • [6] Nanoscale laminin coating modulates cortical scarring response around implanted silicon microelectrode arrays
    He, Wei
    McConnell, George C.
    Bellamkonda, Ravi V.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2006, 3 (04) : 316 - 326
  • [7] Heffner H.E., 1995, METHODS COMP PSYCHOA, P79
  • [8] Design and in vivo evaluation of more efficient and selective deep brain stimulation electrodes
    Howell, Bryan
    Huynh, Brian
    Grill, Warren M.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2015, 12 (04)
  • [9] Hughes C., 2020, PERCEPTUAL RESPONSES, DOI [10.1101/2020.07.16.207506, DOI 10.1101/2020.07.16.207506]
  • [10] Chronic recording and electrochemical performance of amorphous silicon carbide-coated Utah electrode arrays implanted in rat motor cortex
    Joshi-Imre, Alexandra
    Black, Bryan J.
    Abbott, Justin
    Kanneganti, Aswini
    Rihani, Rashed
    Chakraborty, Bitan
    Danda, Vindhya R.
    Maeng, Jimin
    Sharma, Rohit
    Rieth, Loren
    Negi, Sandeep
    Pancrazio, Joseph J.
    Cogan, Stuart F.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2019, 16 (04)