A Magnetically Controlled Soft Microrobot Steering a Guidewire in a Three-Dimensional Phantom Vascular Network

被引:228
作者
Jeon, Sungwoong [1 ,2 ]
Hoshiar, Ali Kafash [1 ,2 ]
Kim, Kangho [1 ,2 ]
Lee, Seungmin [1 ,2 ]
Kim, Eunhee [1 ,2 ]
Lee, Sunkey [1 ,2 ]
Kim, Jin-young [1 ,2 ]
Nelson, Bradley J. [2 ,3 ]
Cha, Hyo-Jeong [4 ]
Yi, Byung-Ju [4 ]
Choi, Hongsoo [1 ,2 ]
机构
[1] DGIST, Dept Robot Engn, Daegu 42988, South Korea
[2] DGIST, DGIST ETH Microrobot Res Ctr DEMRC, Daegu, South Korea
[3] Swiss Fed Inst Technol, Inst Robot & Intelligent Syst, Zurich, Switzerland
[4] Hanyang Univ, Dept Elect Syst Engn, Ansan, South Korea
基金
新加坡国家研究基金会;
关键词
soft microrobot; guidewire; percutaneous coronary intervention (PCI); steerability; intravascular treatments; magnetic steering; CHRONIC TOTAL OCCLUSIONS; FABRICATION; MANIPULATION; SYSTEM; UPDATE; BIOPSY; MODEL; MRI;
D O I
10.1089/soro.2018.0019
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Magnetically actuated soft robots may improve the treatment of disseminated intravascular coagulation. Significant progress has been made in the development of soft robotic systems that steer catheters. A more challenging task, however, is the development of systems that steer sub-millimeter-diameter guidewires during intravascular treatments; a novel microrobotic approach is required for steering. In this article, we develop a novel, magnetically actuated, soft microrobotic system, increasing the steerability of a conventional guidewire. The soft microrobot is attached to the tip of the guidewire, and it is magnetically steered by changing the direction and intensity of an external magnetic field. The microrobot is fabricated via replica molding and features a soft body made of polydimethylsiloxane, two permanent magnets, and a microspring. We developed a mathematical model mapping deformation of the soft microrobot using a feed-forward approach toward steering. Then, we used the model to steer a guidewire. The angulation of the microrobot can be controlled from 21.1 degrees to 132.7 degrees by using a magnetic field of an intensity of 15 mT. Steerability was confirmed by two-dimensional in vitro tracking. Finally, a guidewire with the soft microrobot was tested by using a three-dimensional (3D) phantom of the coronary artery to verify steerability in 3D space.
引用
收藏
页码:54 / 68
页数:15
相关论文
共 43 条
[11]   Hyperthermia with rotating magnetic nanowires inducing heat into tumor by fluid friction [J].
Egolf, Peter W. ;
Shamsudhin, Naveen ;
Pane, Salvador ;
Vuarnoz, Didier ;
Pokki, Juho ;
Pawlowski, Anne-Gabrielle ;
Tsague, Paulin ;
de Marco, Bastien ;
Bovy, William ;
Tucev, Sinisa ;
Ansari, M. H. D. ;
Nelson, Bradley J. .
JOURNAL OF APPLIED PHYSICS, 2016, 120 (06)
[12]   Omni Directional Multimaterial Soft Cylindrical Actuator and Its Application as a Steerable Catheter [J].
Gul, Jahan Zeb ;
Yang, Young Jin ;
Su, Kim Young ;
Choi, Kyung Hyun .
SOFT ROBOTICS, 2017, 4 (03) :224-240
[13]   Biopsy with Thermally-Responsive Untethered Microtools [J].
Gultepe, Evin ;
Randhawa, Jatinder S. ;
Kadam, Sachin ;
Yamanaka, Sumitaka ;
Selaru, Florin M. ;
Shin, Eun J. ;
Kalloo, Anthony N. ;
Gracias, David H. .
ADVANCED MATERIALS, 2013, 25 (04) :514-519
[14]   Small diameter active catheter using shape memory alloy [J].
Haga, Y ;
Tanahashi, Y ;
Esashi, M .
MICRO ELECTRO MECHANICAL SYSTEMS - IEEE ELEVENTH ANNUAL INTERNATIONAL WORKSHOP PROCEEDINGS, 1998, :419-424
[15]   A Novel Magnetic Actuation Scheme to Disaggregate Nanoparticles and Enhance Passage across the Blood-Brain Barrier [J].
Hoshiar, Ali Kafash ;
Tuan-Anh Le ;
Ul Amin, Faiz ;
Kim, Myeong Ok ;
Yoon, Jungwon .
NANOMATERIALS, 2018, 8 (01)
[16]   Studies of aggregated nanoparticles steering during magnetic-guided drug delivery in the blood vessels [J].
Hoshiar, Ali Kafash ;
Le, Tuan-Anh ;
Ul Amin, Faiz ;
Kim, Myeong Ok ;
Yoon, Jungwon .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 427 :181-187
[17]   Penetration of an artificial arterial thromboembolism in a live animal using an intravascular therapeutic microrobot system [J].
Jeong, Semi ;
Choi, Hyunchul ;
Go, Gwangjun ;
Lee, Cheong ;
Lim, Kyung Seob ;
Sim, Doo Sun ;
Jeong, Myung Ho ;
Ko, Seong Young ;
Park, Jong-Oh ;
Park, Sukho .
MEDICAL ENGINEERING & PHYSICS, 2016, 38 (04) :403-410
[18]   Enhanced locomotive and drilling microrobot using precessional and gradient magnetic field [J].
Jeong, Semi ;
Choi, Hyunchul ;
Cha, Kyoungrae ;
Li, Jie ;
Park, Jong-oh ;
Park, Sukho .
SENSORS AND ACTUATORS A-PHYSICAL, 2011, 171 (02) :429-435
[19]   Antibacterial and anticancer PDMS surface for mammalian cell growth using the Chinese herb extract paeonol(4-methoxy-2-hydroxyacetophenone) [J].
Jiao, Jiajia ;
Sun, Lili ;
Guo, Zaiyu ;
Hou, Sen ;
Holyst, Robert ;
Lu, Yun ;
Feng, Xizeng .
SCIENTIFIC REPORTS, 2016, 6
[20]   Update on the Management of Chronic Total Occlusions in Coronary Artery Disease [J].
Kearney, Kathleen ;
Hira, Ravi S. ;
Riley, Robert F. ;
Kalyanasundaram, Arun ;
Lombardi, William L. .
CURRENT ATHEROSCLEROSIS REPORTS, 2017, 19 (04)