An improved method for the measurement of colour uniformity in pellet coating

被引:23
作者
Chan, LW [1 ]
Chan, WY [1 ]
Heng, PWS [1 ]
机构
[1] Natl Univ Singapore, Dept Pharm, Singapore 119260, Singapore
关键词
tristimulus colorimeter; fluidised bed; CIELAB units; coating; colour uniformity;
D O I
10.1016/S0378-5173(00)00619-0
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Sucrose pellets in the size range of 0.71-0.85 mm were film-coated in a bottom-spray Wurster fluidised bed coater with a colour coating suspension of 7.5% w/w solids. Hydroxypropyl methylcellulose was used as a film former, polyethylene glycol as a plasticiser and yellow iron oxide as a coloured pigment. The colour distribution on the film coat was analysed using a tristimulus colorimeter and the colour value was measured in CIELAB units. Uniformity in the colour coat was indicated by the standard deviation of the colour measurement values. Four different methods for measuring the colour distribution over the colour coated pellets' surfaces were carried out. In method I, colour measurements of the pellets' surfaces were made by placing the pellets directly on the stage of the tristimulus colorimeter. A specially designed pellet sample holder was employed to assist the collection of colour measurements in methods II-IV. Colour measurements from eight spots on each pellet were taken in methods I: II and IV while method III involved measuring 24 spots per pellet. A total of eight overlapping spot measurements were taken in method IV while the eight spot measurements in method II were non-overlapping. Method II was found to be the most efficient, accurate and sensitive method for the measurement of spot colour distribution on pellets. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 74
页数:12
相关论文
共 10 条
[1]  
Bilmeyer FW, 1981, COLOR COLOR DIFFEREN, P67
[2]   Qualitative description of the Wurster-based fluid-bed coating process [J].
Christensen, FN ;
Bertelsen, P .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1997, 23 (05) :451-463
[3]  
COLE G, 1995, COATING PANS COATING, P203
[4]  
Heng PWS, 1999, STP PHARMA SCI, V9, P539
[5]  
HUNTER RS, 1981, PHARM TECHNOL, V5, P63
[6]  
Hunter RS, 1987, INSTRUMENTS CHROMATI, P296
[7]  
Judd DB, 1975, TOOLS TECHNICS, P105
[8]   ANALYSIS OF SERIAL MEASUREMENTS IN MEDICAL-RESEARCH [J].
MATTHEWS, JNS ;
ALTMAN, DG ;
CAMPBELL, MJ ;
ROYSTON, P .
BRITISH MEDICAL JOURNAL, 1990, 300 (6719) :230-235
[9]   Instrumental evaluation of color of solid dosage forms during stability testing [J].
Stark, G ;
Fawcett, JP ;
Tucker, IG ;
Weatherall, IL .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 143 (01) :93-100
[10]   INSTRUMENTAL COLOR MEASUREMENT - A METHOD FOR JUDGING THE APPEARANCE OF TABLETS [J].
WIRTH, M .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1991, 80 (12) :1177-1179