Hb mass measurement suitable to screen for illicit autologous blood transfusions

被引:39
作者
Pottgiesser, Torben [1 ]
Umhau, Markus
Ahlgrim, Christoph
Ruthardt, Sebastian
Roecker, Kai
Schumacher, Yorck Olaf
机构
[1] Med Univ Klin, Abt Pravent Rehabil & Sportsmed, D-79095 Freiburg, Germany
[2] Univ Freiburg Klinikum, Zent Einrichtung Transfus Med, Freiburg, Germany
关键词
exercise; hemoglobin mass; carbon monoxide rebreathing; blood doping; antidoping;
D O I
10.1249/mss.0b013e318123e8a6
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: An increase of hemoglobin (Hb) mass is the key target of blood doping practices to enhance performance as it is a main determinant of maximal oxygen uptake. Although detection methods exist for doping with recombinant EPO and homologous blood transfusions, autologous transfusions remain virtually undetectable. In this context, the most sensitive parameter would be a determination of Hb mass itself The purpose therefore was to establish whether Hb mass measurements by the optimized CO-rebreathing method allow screening for the withdrawal and reinfusion of autologous red blood cells. Methods: The optimized CO-rebreathing method was used for evaluation of Hb mass in two groups at three time points (duplicate measurements: 1) baseline, 2) after donation, and 3) after reinfusion). Group I (N = 6) was to donate and receive I unit of packed red cells (PRC) in contrast to two PRC in group II (N = 4). The time span between withdrawal and reinfusion was 2 d. Results: The mean Hb content of the blood units was 59.0 +/- 3.9 g (group I) and 108.3 +/- 1.3 g (group II). Hb mass decreased significantly after blood withdrawal (-89 +/- 16 g in group I and -120 +/- 14 g in group II) and increased significantly after reinfusion (group I: 70 +/- 16 g; group II: 90 +/- 9 g) but was lower than at baseline (group I: -19 + - 17 g; group II: -30 +/- 14 g). The total error of measurements for the duplicate measures ranged between 0.8 and 3.1% (Hb mass: 6.4-22.1 g). Conclusion: Hb mass determination with the optimized CO-rebreathing method has sufficient precision to detect the absolute differences in Hb mass induced by blood withdrawal and autologous reinfusion. Thus, it may be suited to screen for artificially induced alterations in Hb mass.
引用
收藏
页码:1748 / 1756
页数:9
相关论文
共 29 条
[1]  
Ashenden M, 2006, HAEMATOLOGICA, V91, P1143
[2]   Live high, train low does not change the total haemoglobin mass of male endurance athletes sleeping at a simulated altitude of 3000 m for 23 nights [J].
Ashenden, MJ ;
Gore, CJ ;
Dobson, GP ;
Hahn, AG .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1999, 80 (05) :479-484
[3]   DETECTION OF AUTOLOGOUS BLOOD-TRANSFUSIONS IN CROSS-COUNTRY SKIERS [J].
BERGLUND, B ;
HEMMINGSSON, P ;
BIRGEGARD, G .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1987, 8 (02) :66-70
[4]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[5]   Eighteen days of "living high, training low" stimulate erythropoiesis and enhance aerobic performance in elite middle-distance runners [J].
Brugniaux, JV ;
Schmitt, L ;
Robach, P ;
Nicolet, G ;
Fouillot, JP ;
Moutereau, S ;
Lasne, F ;
Pialoux, V ;
Saas, P ;
Chorvot, MC ;
Cornolo, J ;
Olsen, NV ;
Richalet, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) :203-211
[6]   DETERMINATION OF HEMOGLOBIN MASS AND BLOOD-VOLUME WITH CO - EVALUATION AND APPLICATION OF A METHOD [J].
BURGE, CM ;
SKINNER, SL .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (02) :623-631
[7]  
*COUNC EUR PUBL, 2005, GUID PREP US QUAL AS
[8]  
CRAMER RB, 1985, ROLLING STONE, V14, P25
[9]  
Damsgaard R, 2006, HAEMATOL-HEMATOL J, V91, P1006
[10]  
GLEDHILL N, 1982, MED SCI SPORT EXER, V14, P183