RETRACTED: Preconcentration and solid phase extraction method for the determination of Co, Cu, Ni, Zn and Cd in environmental and biological samples using activated carbon by FAAS (Retracted article. See vol. 156, pg. 624, 2008)

被引:22
作者
Kiran, K.
Kumar, K. Suresh
Suvardhan, K.
Janardhanam, K. [1 ]
Chiranjeevi, P.
机构
[1] Sri Venkateswara Univ, Dept Environm Sci, Tirupati 517502, Andhra Pradesh, India
[2] Sri Venkateswara Univ, Dept Chem, Tirupati 517502, Andhra Pradesh, India
关键词
2-{[1-(2-Hydroxynaphthyl) methylidene] amino} benzoic acid (HNMABA); solid phase extraction; activated carbon; environmental and biological samples; flame atomic absorption spectrometry;
D O I
10.1016/j.jhazmat.2006.12.044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
2-{ [1-(2-Hydroxynaphthyl) methylidene] amino} benzoic acid (HNMABA) was synthesized for solid phase extraction (SPE) to the determination of Co, Cu, Ni, Zn and Cd in environmental and biological samples by flame atomic absorption spectrophotometry (FAAS). These metals were sorbed as HNMABA complexes on activated carbon (AC) at the pH range of 5.0 +/- 0.2 and eluted with 6 ml of I M HNO3 in acetone. The effects of sample volume, eluent volume and recovery have been investigated to enhance the sensitivity and selectivity of proposed method. The effect of interferences on the sorption of metal ions was studied. The concentration of the metal ions detected after preconcentration was in agreement with the added amount. The detection limits for the metals studied were in the range of 0.75-3.82 mu g ml(-1). The proposed system produced satisfactory results for the determination of Co, Cu, Ni, Zn and Cd metals in environmental and biological samples. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 33 条
[1]   Determination of Cu, Zn and Cd in water by FAAS after preconcentration by baker's yeast (Saccharomyces cerevisiae) immobilized on sepiolite [J].
Bag, H ;
Lale, M ;
Türker, AR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (03) :224-230
[3]   A low-cost flame atomic absorption spectrometry method for determination of trace metals in aqueous samples [J].
Carasek, E .
TALANTA, 2000, 51 (01) :173-178
[4]   On-line preconcentration of cobalt in drinking water using a minicolumn packed with activated carbon coupled to electrothermal atomic absorption spectrometric determination [J].
Cerutti, S ;
Moyano, S ;
Gásquez, JA ;
Stripeikis, J ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (11) :2015-2021
[5]   On-line preconcentration with different solid adsorbents for lead determination [J].
da Silva, JBB ;
Quináia, SP ;
Rollemberg, MCE .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :657-660
[6]   Sorption of zinc ions from aqueous solutions on regenerated activated carbons [J].
Dabek, L .
JOURNAL OF HAZARDOUS MATERIALS, 2003, 101 (02) :191-201
[7]   Multi-element preconcentration of heavy metal ions from aqueous solution by APDC impregnated activated carbon [J].
Daorattanachai, P ;
Unob, FF ;
Imyim, A .
TALANTA, 2005, 67 (01) :59-64
[8]   Applying magnesium hydroxide coprecipitation method for trace analysis to dialysis concentrate [J].
Elci, L ;
Saracoglu, S .
TALANTA, 1998, 46 (06) :1305-1310
[9]  
FRITZ JS, 1999, ANAL SOLID PHASE EXT
[10]  
Ghiasvand AR, 2005, ASIAN J CHEM, V17, P2143