Reduction of water evaporation in polymerase chain reaction microfluidic devices based on oscillating-flow

被引:22
作者
Polini, Alessandro [1 ,2 ]
Mele, Elisa [3 ]
Sciancalepore, Anna Giovanna [1 ]
Girardo, Salvatore [1 ]
Biasco, Adriana [1 ]
Camposeo, Andrea [1 ]
Cingolani, Roberto [4 ]
Weitz, David A. [5 ,6 ]
Pisignano, Dario [1 ,2 ,3 ]
机构
[1] Univ Salento, NNL, CNR, Ist Nanosci, I-73100 Lecce, Italy
[2] Univ Salento, Scuola Super ISUFI, I-73100 Lecce, Italy
[3] IIT, Ctr Biomol Nanotechnol, I-73100 Arnesano, LE, Italy
[4] IIT, I-16163 Genoa, Italy
[5] Harvard Univ, Dept Phys, Cambridge, MA 02138 USA
[6] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
关键词
biological techniques; biomedical equipment; bioMEMS; drops; elastomers; evaporation; fluid oscillations; lab-on-a-chip; microchannel flow; two-phase flow; water; REAL-TIME PCR; TEMPERATURE CONTROL; DNA AMPLIFICATION; CHIP; CAPILLARY; MICROCHIP; SYSTEMS; POLY(DIMETHYLSILOXANE); EXTRACTION; GRADIENT;
D O I
10.1063/1.3481776
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Producing polymeric or hybrid microfluidic devices operating at high temperatures with reduced or no water evaporation is a challenge for many on-chip applications including polymerase chain reaction (PCR). We study sample evaporation in polymeric and hybrid devices, realized by glass microchannels for avoiding water diffusion toward the elastomer used for chip fabrication. The method dramatically reduces water evaporation in PCR devices that are found to exhibit optimal stability and effective operation under oscillating-flow. This approach maintains the flexibility, ease of fabrication, and low cost of disposable chips, and can be extended to other high-temperature microfluidic biochemical reactors. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3481776]
引用
收藏
页数:10
相关论文
共 43 条
[1]   Glass coating for PDMS microfluidic channels by sol-gel methods [J].
Abate, Adam R. ;
Lee, Daeyeon ;
Do, Thao ;
Holtze, Christian ;
Weitz, David A. .
LAB ON A CHIP, 2008, 8 (04) :516-518
[2]   VAPOR SORPTION AND PERMEATION PROPERTIES OF POLY(DIMETHYLSILOXANE) FILMS [J].
BLUME, I ;
SCHWERING, PJF ;
MULDER, MHV ;
SMOLDERS, CA .
JOURNAL OF MEMBRANE SCIENCE, 1991, 61 :85-97
[3]   Breakup of drops and bubbles translating through cylindrical capillaries [J].
Borhan, A ;
Pallinti, J .
PHYSICS OF FLUIDS, 1999, 11 (10) :2846-2855
[4]   Design and theoretical evaluation of a novel microfluidic device to be used for PCR [J].
Bu, MQ ;
Melvin, T ;
Ensell, G ;
Wilkinson, JS ;
Evans, AGR .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (04) :S125-S130
[5]   Thermally-actuated, phase change flow control for microfluidic systems [J].
Chen, ZY ;
Wang, J ;
Qian, SZ ;
Bau, HH .
LAB ON A CHIP, 2005, 5 (11) :1277-1285
[6]   Performing microchannel temperature cycling reactions using reciprocating reagent shuttling along a radial temperature gradient [J].
Cheng, JY ;
Hsieh, CJ ;
Chuang, YC ;
Hsieh, JR .
ANALYST, 2005, 130 (06) :931-940
[7]   A closed cycle capillary polymerase chain reaction machine [J].
Chiou, J ;
Matsudaira, P ;
Sonin, A ;
Ehrlich, D .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :2018-2021
[8]   Thirty-cycle temperature optimization of a closed-cycle capillary PCR machine [J].
Chiou, JT ;
Matsudaira, PT ;
Ehrlich, DJ .
BIOTECHNIQUES, 2002, 33 (03) :557-+
[9]   Continuous-flow thermal gradient PCR [J].
Crews, Niel ;
Wittwer, Carl ;
Gale, Bruce .
BIOMEDICAL MICRODEVICES, 2008, 10 (02) :187-195
[10]   Autonomous microfluidic multi-channel chip for real-time PCR with integrated liquid handling [J].
Frey, Olivier ;
Bonneick, Sonja ;
Hierlemann, Andreas ;
Lichtenberg, Jan .
BIOMEDICAL MICRODEVICES, 2007, 9 (05) :711-718