On probing human fingertips in vivo using near-infrared light: model calculations

被引:23
作者
Chaiken, Joseph [1 ]
Goodisman, Jerry
机构
[1] Syracuse Univ, Dept Chem, Ctr Sci & Technol, Syracuse, NY 13244 USA
关键词
Raman; in vivo; blood analysis; glucose; noninvasive; RAMAN-SPECTROSCOPY; OPTICAL-PROPERTIES; HUMAN SKIN;
D O I
10.1117/1.3431119
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We probe volar-side fingertip capillary beds with near-infrared laser light and collect Raman, Rayleigh, and Mie scattered light and fluorescence. The results are interpreted using radiation transfer theory in the single-scattering approximation. The surface topography of the skin is modeled using the Fresnel equations. The skin is treated as a three-layer material, with a mean-field treatment of tissue composition and related optical properties. The model, with a reasonable choice of tissue parameters, gives a remarkably accurate account of the features of actual measurements. It predicts the optimal values for the incident angle of the laser beam and the distance between beam and detector. It explains the correlated temporal changes in the intensities of elastically and inelastically scattered light caused by heart-driven pulses and why they are out of phase. With appropriate boundary conditions, the model can be used to discuss the scattering from ridged skin extruded conformally into an aperture in a metal surface under constant light pressure. The probing results suggest an inherent regularity and similarity in the anatomy and composition of surface and subsurface tissues of a wide range of skin types. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3431119]
引用
收藏
页数:15
相关论文
共 32 条
[1]  
[Anonymous], 2005, Raman spectroscopy for chemical analysis M
[2]  
[Anonymous], 1980, PRINCIPLES OPTICS
[3]  
ASHBAUGH SD, 1999, QUANTITATIVE QUALITA
[4]   Turbidity-Corrected Raman Spectroscopy for Blood Analyte Detection [J].
Barman, Ishan ;
Singh, Gajendra P. ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
ANALYTICAL CHEMISTRY, 2009, 81 (11) :4233-4240
[5]   Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin [J].
Caspers, PJ ;
Lucassen, GW ;
Puppels, GJ .
BIOPHYSICAL JOURNAL, 2003, 85 (01) :572-580
[6]   Effect of hemoglobin concentration variation on the accuracy and precision of glucose analysis using tissue modulated, noninvasive, in vivo Raman spectroscopy of human blood:: a small clinical study -: art. no. 031111 [J].
Chaiken, J ;
Finney, W ;
Knudson, PE ;
Weinstock, RS ;
Khan, M ;
Bussjager, RJ ;
Hagrman, D ;
Hagrman, P ;
Zhao, YW ;
Peterson, CM ;
Peterson, K .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
[7]   Progress in the noninvasive, in-vivo, tissue modulated Raman spectroscopy of human blood [J].
Chaiken, J ;
Finney, WF ;
Yang, XK ;
Knudson, PE ;
Peterson, KP ;
Peterson, CM ;
Weinstock, RS ;
Hagrman, D .
BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS III, 2001, 4254 :216-227
[8]   Instrument for near infrared emission spectroscopic probing of human fingertips in vivo [J].
Chaiken, J. ;
Deng, Bin ;
Bussjager, Rebecca J. ;
Shaheen, George ;
Rice, David ;
Stehlik, Dave ;
Fayos, John .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (03)
[9]   Noninvasive, in vivo, tissue modulated near infrared vibrational spectroscopic study of mobile and static tissues: blood chemistry [J].
Chaiken, J ;
Finney, WF ;
Peterson, CM ;
Peterson, KP ;
Knudson, PE ;
Weinstock, RS ;
Lein, P .
BIOMEDICAL SPECTROSCOPY: VIBRATIONAL SPECTROSCOPY AND OTHER NOVEL TECHNIQUES, 2000, 3918 :135-143
[10]  
CHAIKEN J, 2006, P SPIE, V6093