Spatial-temporal ultrasound imaging of residual cavitation bubbles around a fluid-tissue interface in histotripsy

被引:22
作者
Hu, Hong [1 ]
Xu, Shanshan [1 ]
Yuan, Yuan [1 ]
Liu, Runna [1 ]
Wang, Supin [1 ]
Wan, Mingxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Biomed Informat Engn, Dept Biomed Engn, Minist Educ,Sch Life Sci & Technol, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
INTENSITY FOCUSED ULTRASOUND; INERTIAL CAVITATION; CLOUD DYNAMICS; THERAPY; BACKSCATTER; THRESHOLDS; EROSION; PULSES; HIFU;
D O I
10.1121/1.4919286
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cavitation is considered as the primary mechanism of soft tissue fragmentation (histotripsy) by pulsed high-intensity focused ultrasound. The residual cavitation bubbles have a dual influence on the histotripsy pulses: these serve as nuclei for easy generation of new cavitation, and act as strong scatterers causing energy "shadowing." To monitor the residual cavitation bubbles in histotripsy, an ultrafast active cavitation imaging method with relatively high signal-to-noise ratio and good spatial-temporal resolution was proposed in this paper, which combined plane wave transmission, minimum variance beamforming, and coherence factor weighting. The spatial-temporal evolutions of residual cavitation bubbles around a fluid-tissue interface in histotripsy under pulse duration (PD) of 10-40 mu s and pulse repetition frequency (PRF) of 0.67-2 kHz were monitored by this method. The integrated bubble area curves inside the tissue interface were acquired from the bubble image sequence, and the formation process of histotripsy damage was estimated. It was observed that the histotripsy efficiency decreased with both longer PDs and higher PRFs. A direct relationship with a coefficient of 1.0365 between histotripsy lesion area and inner residual bubble area was found. These results can assist in monitoring and optimization of the histotripsy treatment further. (C) 2015 Acoustical Society of America.
引用
收藏
页码:2563 / 2572
页数:10
相关论文
共 37 条
[1]   HIGHER-ORDER SPECTRA BASED DECONVOLUTION OF ULTRASOUND IMAGES [J].
ABEYRATNE, UR ;
PETROPULU, AP ;
REID, JM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (06) :1064-1075
[2]   Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (04) :858-867
[3]   Minimum Variance Beamforming Combined with Adaptive Coherence Weighting Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (09) :1923-1931
[4]   THRESHOLDS FOR CAVITATION PRODUCED IN WATER BY PULSED ULTRASOUND [J].
ATCHLEY, AA ;
FRIZZELL, LA ;
APFEL, RE ;
HOLLAND, CK ;
MADANSHETTY, S ;
ROY, RA .
ULTRASONICS, 1988, 26 (05) :280-285
[5]   Sonochemiluminescence observation and acoustic detection of cavitation induced by pulsed HIFU at a tissue-fluid interface [J].
Cao, Hua ;
Yin, Hui ;
Qiao, Yangzi ;
Zhang, Shusheng ;
Wan, Mingxi .
ULTRASONICS SONOCHEMISTRY, 2013, 20 (06) :1370-1375
[6]   HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS [J].
CAPON, J .
PROCEEDINGS OF THE IEEE, 1969, 57 (08) :1408-&
[7]   Spatial-temporal dynamics of cavitation bubble clouds in 1.2 MHz focused ultrasound field [J].
Chen, Hong ;
Li, Xiaojing ;
Wan, Mingxi .
ULTRASONICS SONOCHEMISTRY, 2006, 13 (06) :480-486
[8]   The pulse length-dependence of inertial cavitation dose and hemolysis [J].
Chen, WS ;
Brayman, AA ;
Matula, TJ ;
Crum, LA ;
Miller, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (05) :739-748
[9]   Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU) [J].
Coussios, C. C. ;
Farny, C. H. ;
Ter Haar, G. ;
Roy, R. A. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (02) :105-120
[10]   ROBUST ADAPTIVE BEAMFORMING [J].
COX, H ;
ZESKIND, RM ;
OWEN, MM .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1987, 35 (10) :1365-1376