Influence of hydrolytic degradation on the surface properties of poly-5D/95L-lactide resorbable bone plates

被引:6
作者
Hu, Hsin-Tai [2 ]
Shin, Tsai-Chin [2 ]
Lee, Sheng-Yang [2 ]
Chen, Chien-Chung [3 ]
Yang, Jen-Chang [1 ]
机构
[1] Taipei Med Univ, Coll Oral Med, Sch Dent Technol, Taipei 11052, Taiwan
[2] Taipei Med Univ, Sch Dent, Coll Oral Med, Taipei 11052, Taiwan
[3] Taipei Med Univ, Coll Oral Med, Grad Inst Biomed Mat & Engn, Taipei 11052, Taiwan
关键词
PLA95 (poly-5D/95L-lactide); Resorbable bone plates; In vitro degradation; ATR-FTIR; MDSC; Surface morphology; LONG-TERM DEGRADATION; POLY-L-LACTIDE; IN-VIVO; POLY(L-LACTIDE); FIXATION; CRYSTALLIZATION; OSTEOTOMIES; MORPHOLOGY; IMPLANTS; BEHAVIOR;
D O I
10.1016/j.polymdegradstab.2011.04.020
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
This study explores in vitro aging effects on the surface properties of resorbable PLA95 (poly-5D/95L-lactide) bone plates. The in vitro degradation of injection molded PLA95 bone plates was undertaken by soaking them in a PBS solution. Specimens were harvested at 0, 4, 6, 8, 12, 20, and 26 weeks. After each in vitro aging period, the surface morphology, viscosity, chemical structure, wettability, and thermal properties of the PLA95 bone plates were examined by scanning electron microscopy (SEM), capillary viscometers, attenuated total reflection fourier transform infrared spectroscopy (ATR-FTIR), contact angle, and modulated differential scanning calorimetry (MDSC), respectively. The surface morphology of aged PLA95 bone plates exhibited bulk erosion. As hydrolysis progressed, the inherent viscosity (IV.) of the PLA95 plates gradually decreased from 0.83 +/- 0.01 dL/g at week 0-0.46 +/- 0.03 dL/g at week 26. However, the absorbance peak intensity ratio between delta(as) (CH3) (A(1452) cm(-1)) and v (C)=(O) (A(1750) cm(-1)) and the contact angle reveal different tendencies than that of molecular weight, which decreases. The contact angle of the PLA95 plates decreased until week 4, increased until week 8, and subsequently decreased again. Peak separation analysis reveals that the equilibrium part of the modulated DSC overlapped curves exhibit triple endothermic peaks. Over time, in vitro degradation changes the position and area of the individual peaks. After different time periods of degradation, the variation of wettability shows a tendency similar to the change of PLA95 plates crystallinity; the intensity ratio of A(1452) cm(-1) and A(1750) cm(-1) (delta(as) (CH3)/v(C)=(O)) absorbance peaks varied like the ratio of beta/alpha-crystal heat of fusion. Results also show a similarity in the degradation time dependence in MDSC, contact angle, and ATR-MR measurements. During the in vitro aging process, the breakdown and subsequent recrystallization of PLA95 molecular chains might be attributed to a progressive change in wettability and the molecular conformation between delta a(s CH3) and v (C)=(O). (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1522 / 1529
页数:8
相关论文
共 25 条
[1]   MECHANISMS OF POLYMER DEGRADATION IN IMPLANTABLE DEVICES .2. POLY(DL-LACTIC ACID) [J].
ALI, SAM ;
DOHERTY, PJ ;
WILLIAMS, DF .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (11) :1409-1418
[2]   Blends as a strategy towards tailored hydrolytic degradation of poly(ε-caprolactone-co-D,L-lactide)-poly(ethylene glycol)-poly(ε-caprolactone-co-D,L-lactide) co-polymers [J].
Bramfeldt, Hanna ;
Sarazin, Pierre ;
Vermette, Patrick .
POLYMER DEGRADATION AND STABILITY, 2008, 93 (04) :877-882
[3]  
BUECHEL FF, 1989, CLIN ORTHOP RELAT R, P34
[4]   Titanium miniplate fixation for osteotomies in facial fibrous dysplasia - A histologic study of the screw bone interface [J].
Cheung, LK ;
Samman, N ;
Pang, M ;
Tideman, H .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (06) :401-405
[5]   Cytotoxicity of poly(96L/4D-lactide): the influence of degradation and sterilization [J].
Cordewener, FW ;
van Geffen, MF ;
Joziasse, CAP ;
Schmitz, JP ;
Bos, RRM ;
Rozema, FR ;
Pennings, AJ .
BIOMATERIALS, 2000, 21 (23) :2433-2442
[6]   Degradation characteristics of PLLA-PGA bone fixation devices [J].
Eppley, BL ;
Reilly, M .
JOURNAL OF CRANIOFACIAL SURGERY, 1997, 8 (02) :116-120
[7]   HYDROLYTIC DEGRADATION OF DEVICES BASED ON POLY(DL-LACTIC ACID) SIZE-DEPENDENCE [J].
GRIZZI, I ;
GARREAU, H ;
LI, S ;
VERT, M .
BIOMATERIALS, 1995, 16 (04) :305-311
[8]  
HOLLINGER JO, 1986, CLIN ORTHOP RELAT R, P290
[9]   CRYSTAL-STRUCTURE, CONFORMATION, AND MORPHOLOGY OF SOLUTION-SPUN POLY(L-LACTIDE) FIBERS [J].
HOOGSTEEN, W ;
POSTEMA, AR ;
PENNINGS, AJ ;
TENBRINKE, G ;
ZUGENMAIER, P .
MACROMOLECULES, 1990, 23 (02) :634-642
[10]   Crystallization and microstructure of poly(L-lactide-co-meso-lactide) copolymers [J].
Huang, J ;
Lisowski, MS ;
Runt, J ;
Hall, ES ;
Kean, RT ;
Buehler, N ;
Lin, JS .
MACROMOLECULES, 1998, 31 (08) :2593-2599