Challenges of Glaucoma Management in Patients with Type I Boston Keratoprosthesis

被引:2
作者
AlHilali, Sara M. [1 ]
Al-Swailem, Samar A. [1 ]
机构
[1] King Khalid Eye Specialist Hosp, External Eye Dis & Refract Surg Div, Cornea, Riyadh, Saudi Arabia
关键词
glaucoma; Boston keratoprosthesis; management; surveillance; complications; INTRAOCULAR-PRESSURE; DRAINAGE DEVICES; OUTCOMES; COMPLICATIONS; IMPLANTATION; PROGRESSION; SURGERY; DAMAGE; EYES;
D O I
10.2147/OPTH.S349719
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Type I Boston keratoprosthesis is implanted in patients with severely diseased eyes who are considered poor candidates for traditional keratoplasty. Glaucoma is considered a major visual comorbidity following the implantation of type I Boston keratoprosthesis (KPro). Eyes that receive a Boston KPro are at high risk of progression of pre-existing glaucoma and the development of de novo glaucoma. Both complications can limit best-corrected visual acuity postoperatively. Diagnosis and surveillance for glaucoma in KPro eyes are fundamental to mitigate the risk of visual morbidity. However, managing these patients presents several challenges. The diagnosis of glaucoma after KPro implantation is usually hindered by inaccurate intraocular pressure (IOP) measurements and unreliable ophthalmic investigations such as visual field testing and optical coherence tomography (OCT) of the retinal nerve fiber layer (RNFL). In these eyes, medical management of glaucoma with topical medications is usually insufficient, and glaucoma surgery is usually warranted either prior to or during KPro implantation. Options for glaucoma surgery include glaucoma drainage device (GDD) and cyclodestructive procedures. The aim of this article is to highlight the incidence, pathophysiology, diagnosis, and management options of glaucoma in eyes that have undergone type I Boston keratoprosthesis.
引用
收藏
页码:369 / 374
页数:6
相关论文
共 43 条
[11]   Glaucoma Risk Factors and Outcomes Following Boston Keratoprosthesis Type 1 Surgery [J].
Geoffrion, Dominique ;
Harissi-Dagher, Mona .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 226 :56-67
[12]   Outcomes of Pars Plana Glaucoma Drainage Implant in Boston Type 1 Keratoprosthesis Surgery [J].
Huh, Eun S. ;
Aref, Ahmad A. ;
Vajaranant, Thasarat S. ;
de la Cruz, Jose ;
Chau, Felix Y. ;
Cortina, Maria S. .
JOURNAL OF GLAUCOMA, 2014, 23 (01) :E39-E44
[13]   Cyclophotocoagulation in the Control of Glaucoma in Patients With the Boston Keratoprosthesis Type 1 [J].
Jabbour, Samir ;
Harissi-Dagher, Mona ;
Agoumi, Younes ;
Singh, Harmanjit ;
Robert, Marie-Claude .
CORNEA, 2020, 39 (02) :181-185
[14]   Glaucoma Associated With Boston Type I Keratoprosthesis [J].
Kamyar, Roheena ;
Weizer, Jennifer S. ;
de Paula, Fernando Heitor ;
Stein, Joshua D. ;
Moroi, Sayoko E. ;
John, Denise ;
Musch, David C. ;
Mian, Shahzad I. .
CORNEA, 2012, 31 (02) :134-139
[15]   Anterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis [J].
Kang, Joann J. ;
Allemann, Norma ;
Vajaranant, Thasarat ;
de la Cruz, Jose ;
Cortina, Maria Soledad .
PLOS ONE, 2013, 8 (08)
[16]   Serial Analysis of Anterior Chamber Depth and Angle Status Using Anterior Segment Optical Coherence Tomography After Boston Keratoprosthesis [J].
Kang, Joann J. ;
Allemann, Norma ;
de la Cruz, Jose ;
Cortina, Maria Soledad .
CORNEA, 2013, 32 (10) :1369-1374
[17]   Three-Dimensional Optical Coherence Tomography Imaging For Glaucoma Associated With Boston Keratoprosthesis Type I and II [J].
Khoueir, Ziad ;
Jassim, Firas ;
Braaf, Boy ;
Poon, Linda Yi-Chieh ;
Tsikata, Edem ;
Chodosh, James ;
Dohlman, Claes H. ;
Vakoc, Benjamin J. ;
Bouma, Brett E. ;
de Boer, Johannes F. ;
Chen, Teresa C. .
JOURNAL OF GLAUCOMA, 2019, 28 (08) :718-726
[18]   Implantation of a Novel Telemetric Intraocular Pressure Sensor in Patients With Glaucoma (ARGOS Study): 1-Year Results [J].
Koutsonas, Antonis ;
Walter, Peter ;
Roessler, Gernot ;
Plange, Niklas .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (02) :1063-1069
[19]   The Aachen-keratoprosthesis - a flexible KPro that permits intraocular pressure measurement [J].
Krug, A ;
Kompa, S ;
Schrage, NF .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (03) :238-242
[20]   Technique of Combined Glaucoma Tube Shunt and Keratoprosthesis Implantation [J].
Law, Simon K. ;
Huang, Jennifer S. ;
Nassiri, Nariman ;
Moghimi, Sasan ;
Nilforushan, Naveed ;
Parham, Azarbod ;
Moossai, Jonathan ;
Kim, Michelle ;
Caprioli, Joseph ;
Aldave, Anthony J. .
JOURNAL OF GLAUCOMA, 2014, 23 (08) :501-507