Electrochemical sensing of trimethylamine based on polypyrrole-flavin-containing monooxygenase (FMO3) and ferrocene as redox probe for evaluation of fish freshness

被引:24
作者
Bourigua, Sondes [2 ,3 ]
El Ichi, Sarra [1 ,2 ]
Korri-Youssoufi, Hafsa [1 ]
Maaref, Abderrazak [3 ]
Dzyadevych, Serge [4 ]
Renault, Nicole Jaffrezic [2 ]
机构
[1] Univ Paris 11, CNRS UMR 8182, Inst Chim Mol & Mat Orsay, Equipe Chim Bioorgan & Bioinorgan, F-91405 Orsay, France
[2] Univ Lyon 1, Lab Sci Analyt, F-69622 Villeurbanne, France
[3] Fac Sci Monastir, Lab Phys & Chim Interfaces, Monastir 5019, Tunisia
[4] Natl Acad Sci Ukraine, Inst Mol Biol & Genet, Lab Biomol Elect, UA-03143 Kiev, Ukraine
关键词
Trimethylamine biosensor; Flavin-containing monooxygenase 3; Polypyrrole; Ferrocene; Redox probe; Impedance; Amperometry; Fish freshness; GAS-CHROMATOGRAPHY; N-OXIDE; BIOSENSOR; IMMOBILIZATION; ENZYME;
D O I
10.1016/j.bios.2011.07.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Amperometric and impedimetric biosensor for detecting trimethylamine (TMA) which represents good parameters for estimating fish freshness has been developed. The biosensor is based on a conducting polypyrrole substituted with ferrocenyl, where flavin-containing monooxygenase 3 (FMO3) enzyme was immobilised by covalent bonding. FMO3 catalyzes the monooxygenation TMA to trimethylamine N-oxide (IMO). For catalysis FMO require flavin adenine (FAD) as a prosthetic group, NADPH as a cofactor and molecular oxygen as cosubstrate. Ferrocenyl group substituted on the polypyrrole matrix will serve as redox probe for monitoring the response of the biosensor to TMA. The construction of the biosensor was characterized by FT-IR, cyclic voltammetry and impedance measurements. Detection is done through the analysis of the current of oxidation signal of the ferrocenyl groups and compared to the measurement of impedance related to the electrical properties of the layers. Amperometric and impedimetric response were measured as a function of TMA concentration in range of 0.4 mu g mL(-1) -80 mu g mL(-1) (6.5 mu mol L(-1)-1.5 mmol L(-1)). Amperometric measurements show a decrease in current response which is in correlation with the increase of the charge transfer resistance demonstrated by impedance. Calibration curve obtained by impedance spectroscopy shows a high sensitivity with a dynamic range from (0.4 mu g mL(-1) to 80 mu g mL(-1)). We demonstrated, using ferrocene as redox probe for catalytic reaction of FMO3, that high sensitivity and dynamic range was obtained. The biosensor was stable during 16 days. The biosensor shows high selectivity and its sensitivity to TMA in real samples was evaluated using fish extract after deterioration during storage. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 24 条
  • [1] Biomolecular immobilization on conducting polymers for biosensing applications
    Ahuja, Tarushee
    Mir, Irfan Ahmad
    Kumar, Devendra
    Rajesh
    [J]. BIOMATERIALS, 2007, 28 (05) : 791 - 805
  • [2] Some distinctions between flavin-containing and cytochrome P450 monooxygenases
    Cashman, JR
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2005, 338 (01) : 599 - 604
  • [3] THE MEASUREMENT OF DIMETHYLAMINE, TRIMETHYLAMINE, AND TRIMETHYLAMINE N-OXIDE USING CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    DACOSTA, KA
    VRBANAC, JJ
    ZEISEL, SH
    [J]. ANALYTICAL BIOCHEMISTRY, 1990, 187 (02) : 234 - 239
  • [4] Validation of a flow-injection-gas diffusion method for total volatile basic nitrogen determination in seafood products
    Dhaouadi, Anissa
    Monser, Lotfi
    Sadok, Saloua
    Adhoum, Nafaa
    [J]. FOOD CHEMISTRY, 2007, 103 (03) : 1049 - 1053
  • [5] FILLIT C, 2008, J MAT SCI ENG C, V28, P781
  • [6] A MICROBIAL BIOSENSOR FOR TRIMETHYLAMINE USING PSEUDOMONAS-AMINOVORANS CELLS
    GAMATI, S
    LUONG, JHT
    MULCHANDANI, A
    [J]. BIOSENSORS & BIOELECTRONICS, 1991, 6 (02) : 125 - 131
  • [7] GILL TA, 1992, QUALITY ASSURANCE FI, V30
  • [8] Direct chemical functionalization of as-grown electroactive polypyrrole film containing leaving groups
    Godillot, P
    KorriYoussoufi, H
    Srivastava, P
    ElKassmi, A
    Garnier, F
    [J]. SYNTHETIC METALS, 1996, 83 (02) : 117 - 123
  • [9] Quality assurance of raw fish based on HACCP concept
    Hamada-Sato, N
    Usui, K
    Kobayashi, T
    Imada, C
    Watanabe, E
    [J]. FOOD CONTROL, 2005, 16 (04) : 301 - 307
  • [10] Investigation of SPR and electrochemical detection of antigen with polypyrrole functionalized by biotinylated single-chain antibody: A review
    Le, H. Q. A.
    Sauriat-Dorizon, H.
    Korri-Youssoufi, H.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 674 (01) : 1 - 8