Cooperation Between Reclosing System and a Flux Coupling Type SFCL by a Neutral Line

被引:4
作者
Choi, Hyo-Sang [1 ]
Cho, Yong-Sun [1 ]
Jung, Byung-Ik [1 ]
Chung, Dong-Chul [2 ]
机构
[1] Chosun Univ, Dept Elect Engn, Kwangju 501759, South Korea
[2] Woosuk Univ, Dept Elect & Elect Engn, Jeonbuk 565701, South Korea
关键词
Flux-coupling type SFCL; neutral line; reclosing cycle; recovery time;
D O I
10.1109/TASC.2010.2096530
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We analysed the protective cooperation between a reclosing system and a flux-coupling type superconducting fault current limiter (SFCL). In order to compare the recovery behavior, the SFCLs without or with a neutral line between secondary coil and superconducting elements were prepared. Most of power grid has a reclosing system, which controls the circuit breaker by the sequential procedure, to cope with various faults. Generally, fast recovery of the SFCL was very important for stable operation between the reclosing system and the SFCL. The reclosing cycles (CO-t-CO-t-CO) for the experiments was set to 5-10-7-20-5. Recovery time in a flux coupling type SFCL without a neutral line was lengthened due to unequal quench between superconducting elements and it caused decrease of the maximum applied voltage. In the meantime, recovery time in the SFCL with a neutral line was shortened due to simultaneous quench between the elements. So, applied voltage of the power system could be higher within same reclosing system. As turn's ratio between secondary coil and superconducting elements was increased, recovery time was longer due to increase of their power. We confirmed that a flux-coupling type SFCL with a neutral line was more profitable for good cooperation between superconducting elements and a reclosing system.
引用
收藏
页码:1221 / 1224
页数:4
相关论文
共 8 条
[1]   Recovery characteristics of resistive SFCL wound with YBCO coated conductor in a power system [J].
Ahn, Min Cheol ;
Park, Dong Keun ;
Yang, Seong Eun ;
Kim, Min Jae ;
Chang, Ho-Myung ;
Yoon, Yong Soo ;
Seok, Bok-Yeol ;
Park, Jung-Wook ;
Ko, Tae Kuk .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :1859-1862
[2]   Current Limiting Characteristics of a Novel Flux-Coupling Type Superconducting Fault Current Limiter [J].
Chen, Lei ;
Tang, Yuejin ;
Li, Zhi ;
Ren, Li ;
Shi, Jing ;
Cheng, Shijie .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) :1139-1142
[3]   Transient Characteristics of a Flux-Coupling Type Superconducting Fault Current Limiter According to Winding Direction [J].
Choi, Hyo-Sang ;
Jung, Byung-Ik ;
Cho, Yong-Sung .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) :1827-1830
[4]   RECLOSING ON SUPERCONDUCTING SYSTEMS [J].
DONALDSON, GW .
IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (01) :449-452
[5]  
Ryu Myunghyo, 2006, Journal of Electrical Engineering & Technology, V1, P351
[6]  
Su-Won Lee, 2008, Journal of Electrical Engineering & Technology, V3, P546, DOI 10.5370/JEET.2008.3.4.546
[7]  
Sung-Hun Lim, 2007, Journal of Electrical Engineering & Technology, V2, P289, DOI 10.5370/JEET.2007.2.3.289
[8]  
Sung-Hun Lim, 2008, Journal of Electrical Engineering & Technology, V3, P213, DOI 10.5370/JEET.2008.3.2.213