Design and optical principles of multifocal lenses

被引:36
作者
Auffarth, G. U. [1 ]
Rabsilber, T. M. [1 ]
Kohnen, T. [2 ]
Holzer, M. P. [1 ]
机构
[1] Univ Augenklin Heidelberg, IVCRC, D-69120 Heidelberg, Germany
[2] Univ Frankfurt Main, Klin Augenheilkunde, Frankfurt, Germany
来源
OPHTHALMOLOGE | 2008年 / 105卷 / 06期
关键词
cataract; multifokal IOLs; diffractive; refractive; aspherical;
D O I
10.1007/s00347-008-1744-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Multifocal intraocular lenses (MIOLs) of different designs have been used for more than 20 years in modern cataract surgery. The first IOLs were either refractive 2-3-zone designs or of diffractive concept. All MIOL types, regardless of manufacturer, show reduced contrast sensitivity and increased glare for years. Nevertheless, even first-generation MIOL patients had very good functional results when patient selection, IOL calculation, and surgical techniques were appropriate. Today's gold standard is foldable, aspherical diffractive, or refractive MIOLS. Advancements in technology allow the possibility that MIOLs will be used for aphakia correction as well as presbyopia correction.
引用
收藏
页码:522 / 526
页数:5
相关论文
共 26 条
[11]   Driving simulation study: Bilateral Array multifocal versus bilateral AMO monofocal intraocular lenses [J].
Featherstone, KA ;
Bloomfield, JR ;
Lang, AJ ;
Miller-Meeks, MJ ;
Woodworth, G ;
Steinert, RF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (09) :1254-1262
[12]   Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
OPHTHALMOLOGY, 2001, 108 (11) :2011-2017
[13]   Presbyopia correction using intraocular lenses [J].
Holzer M.P. ;
Rabsilber T.M. ;
Auffarth G.U. .
Der Ophthalmologe, 2006, 103 (8) :661-666
[14]   Success of monovision in presbyopes: Review of the literature and potential applications to refractive surgery [J].
Jain, S ;
Arora, I ;
Azar, DT .
SURVEY OF OPHTHALMOLOGY, 1996, 40 (06) :491-499
[15]   Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomes - Multicenter clinical trial in Germany and Austria [J].
Javitt, J ;
Brauweiler, HP ;
Jacobi, KW ;
Klemen, U ;
Kohnen, S ;
Quentin, CD ;
Teping, C ;
Pham, T ;
Knorz, MC ;
Poetzsch, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09) :1356-1366
[16]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[17]  
Kaymak H, 2007, OPHTHALMOLOGE, V104, P1046, DOI 10.1007/s00347-007-1582-1
[18]   Apodized diffractive optic - New concept in multifocal lens technology [J].
Kohnen, T. ;
Derhartunian, V. .
OPHTHALMOLOGE, 2007, 104 (10) :899-+
[19]   European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens [J].
Kohnen, T ;
Allen, D ;
Boureau, C ;
Dublineau, P ;
Hartmann, C ;
Mehdorn, E ;
Rozot, P ;
Tassinari, G .
OPHTHALMOLOGY, 2006, 113 (04) :578-584
[20]   Functional results with two multifocal intraocular lenses (MIOL): Array SA40 versus Acri.Twin [J].
Mester U. ;
Dillinger P. ;
Anterist N. ;
Kaymak H. .
Der Ophthalmologe, 2005, 102 (11) :1051-1056