Distal femoral fixation: A biomechanical comparison of retrograde nail, retrograde intramedullary nail, and prototype locking retrograde nail

被引:15
作者
Heiney, Jake P. [1 ]
Battula, Suneel [2 ]
O'Connor, Jill A. [3 ]
Ebraheim, Nabil [1 ]
Schoenfeld, Andrew J. [4 ]
Vrabec, Gregory [5 ]
机构
[1] Univ Toledo, Med Ctr, Toledo, OH 43614 USA
[2] Zimmer Dent Inc, Carlsbad, CA 92008 USA
[3] ProMedica Hlth Syst, Toledo, OH 43606 USA
[4] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[5] Akron Gen Med Ctr, Akron, OH 44307 USA
关键词
Distal femur fracture fixation; Prototype retrograde femoral nail; Locking nail; LESS INVASIVE STABILIZATION; TIBIAL PLATEAU FRACTURES; ELDERLY-PATIENTS; SUPRACONDYLAR NAILS; FEMUR FRACTURES; OSTEOPOROTIC BONE; BLADE PLATE; SCREWS; EPIDEMIOLOGY; DIAPHYSEAL;
D O I
10.1016/j.clinbiomech.2012.01.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Distal femur fractures continue to be a complex surgical problem for which the incidence is increasing. Presently, there is a need for different constructs to address these complex fractures. This study attempts to define the biomechanical properties of several implants. Methods: A novel, prototype locking retrograde intramedullary nail and the Russell-Taylor femoral retrograde nail were tested at non-destructive, physiological, axial mode load strength using a young, synthetic bone model for a medial segmental shaft defect in the supracondylar region of the distal femur (medial gap of 10 mm, 65 mm proximal to the distal joint and parallel to the knee axis). Each specimen was compressively loaded and unloaded to the peak load for 80,000 cycles at a 0.5 Hz frequency. These were compared to the results from the same lab of the retrograde Trigen intramedullary nail. Motion and peak displacement were measured across the fracture site as a reflection of construct stability. Findings: Previous testing demonstrated that Trigen intramedullary nail had significantly less motion across the gap and increased overall stiffness of the construct (P<0.05) compared to both Russell-Taylor and prototype nails. Interpretation: Locking technology used in a nail biomechanically appears to lead to more micro-motion across the fracture gap and to less stiffness in this construct. Further research needs to be invested into intramedullary, locking technology before introducing it into clinical practice. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:692 / 696
页数:5
相关论文
共 42 条
[1]   Treatment of isolated complex distal femoral fractures by external fixation [J].
Ali, F ;
Saleh, M .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (03) :139-146
[2]  
[Anonymous], 1998, Skeletal tissue mechanics
[3]  
Armstrong R, 2003, ORTHOPEDICS, V26, P627
[4]  
ARNESON TJ, 1988, CLIN ORTHOP RELAT R, P188
[5]   Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material [J].
Battula, Suneel ;
Schoenfeld, Andrew ;
Vrabec, Gregory ;
Njus, Glen O. .
CLINICAL BIOMECHANICS, 2006, 21 (05) :533-537
[6]   Displaced fractures of the distal femur in elderly patients [J].
Butt, MS ;
Krikler, SJ ;
Ali, MS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (01) :110-114
[7]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[8]   Comparative biomechanical analysis of supracondylar femur fracture fixation: Locked intramedullary nail versus 95-degree angled plate [J].
David, SM ;
Harrow, ME ;
Peindl, RD ;
Frick, SL ;
Kellam, JF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) :344-350
[9]   The supracondylar intramedullary nail in elderly patients with distal femoral fractures [J].
Dunlop, DG ;
Brenkel, IJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (07) :475-484
[10]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493