On carbide dissolution in an as-cast ASTM F-75 alloy

被引:66
作者
Caudillo, M
Herrera-Trejo, M
Castro, MR
Ramírez, E
González, CR
Juárez, JI
机构
[1] IPN, Unidad Saltillo, CINVESTAV, Saltillo 25000, Coahuila, Mexico
[2] Univ Nacl Autonoma Mexico, Dept Ingn Met, Fac Quim, Mexico City 04510, DF, Mexico
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2002年 / 59卷 / 02期
关键词
ASTM F-75 alloy; solution treatment; carbide; kinetics;
D O I
10.1002/jbm.10001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The solution treatment of an as-cast ASTM F-75 alloy was investigated. Microstructural evolution was followed during thermal processing, in particular with regard to the content and type of carbides formed. To evidence any probable carbide transformations occurring during the heating stage, as well as to clarify their effect on the carbide dissolution kinetics, three heating rates were studied. Image analysis and scanning electron microscopy techniques were used for. microstructural characterization. For the identification of precipitates, these were electrolytically extracted from the matrix and then analyzed by X-ray diffraction. It was found that the precipitates in the as-cast alloy were constituted by both a M23C6 carbide and a g intermetallic phase. The M23C6 carbide was the only phase identified in solution-treated specimens, regardless of the heating rate employed, which indicated that this carbide dissolved directly into the matrix without being transformed first into an M6C carbide, as reported in the literature. It was found that the kinetics of dissolution for the M23C6 carbide decreased progressively during the solution treatment, and that it was sensitive to the heating rate, decreasing whenever the latter was decreased. Because the M23C6 carbide was not observed to suffer a phase trans form ati on prior to its dissolution into the matrix, the effect of the heating rate was associated to the morphological change occurred as the specimens were heated. The occurrence of the observed phases was analyzed with the aid of phase diagrams computed for the system Co-Cr-Mo-C. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 21 条
[1]   EFFECT OF MICROSTRUCTURE ON PHYSICAL PROPERTIES OF COBALT-BASE ALLOYS [J].
ASGAR, K ;
PEYTON, FA .
JOURNAL OF DENTAL RESEARCH, 1961, 40 (01) :63-&
[2]  
ASGAR K, 1968, J DENT RES, V84, P73
[3]  
ASM, 1985, MET HDB, V9
[4]  
*ASM, 1988, MET HDB, V15
[5]  
*ASTM, 1989, ANN BOOK ASTM F75 ST
[6]   SOLUTION TREATMENT BEHAVIOR OF CO-CR-MO ALLOY [J].
CLEMOW, AJT ;
DANIELL, BL .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1979, 13 (02) :265-279
[7]   RECOMMENDED HEAT-TREATMENT AND ALLOY ADDITIONS FOR CAST CO-CR SURGICAL IMPLANTS [J].
COHEN, J ;
ROSE, RM ;
WULFF, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1978, 12 (06) :935-937
[8]   CAST VS WROUGHT COBALT-CHROMIUM SURGICAL IMPLANT ALLOYS [J].
DEVINE, TM ;
WULFF, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1975, 9 (02) :151-167
[9]   HEAT-TREATMENT OF CAST CO-CR-MO FOR ORTHOPEDIC IMPLANT USE [J].
DOBBS, HS ;
ROBERTSON, JLM .
JOURNAL OF MATERIALS SCIENCE, 1983, 18 (02) :391-401
[10]  
Gomez M, 1997, J BIOMED MATER RES, V34, P157, DOI 10.1002/(SICI)1097-4636(199702)34:2<157::AID-JBM3>3.0.CO