Investigation of crevice corrosion of AISI 316 stainless steel compared to Ni-Cr-Mo alloys using coupled multielectrode arrays

被引:34
作者
Bocher, Florent [1 ]
Presuel-Moreno, Francisco [1 ]
Scully, John R. [1 ]
机构
[1] Univ Virginia, Charlottesville, VA 22904 USA
关键词
D O I
10.1149/1.2883741
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Close-packed coupled multielectrode arrays simulating a planar electrode were used to monitor the anodic current evolution as a function of position during initiation and propagation of crevice corrosion of AISI 316 stainless steel (UNS S31600) and Ni-Cr-Mo alloy 625 (UNS N06625). Scaling laws x(crit)(2) vs G and x(crit)*(2) vs G derived from polarization data in simulated crevice solutions guided the implementation of rescaled crevices with greater spatial resolution. x(crit) and x(crit)* are the distances from the mouth to the location where the potential reaches two different critical values, and G is the crevice gap. Scaling laws were also used along with anodic polarization data in simulated crevice solution to predict crevice corrosion behavior of alloy 22 (UNS N06022). Crevice corrosion of AISI 316 stainless steel in 0.6 mol/L NaCl at 50 degrees C readily initiated close to the crevice mouth (i.e., x(crit)approximate to 0) at modest applied potentials (e.g., E-app=0 V-SCE) and spread both inward and outside the crevice with time. Crevice corrosion initiated farther inside the crevice (i.e., x(crit) is large) and required higher applied potentials (e.g., E-app=50 mV(SCE)) in the case of alloy 625. The local crevice current density increased dramatically over a short period of time to reach a limiting value in the case of AISI 316; while metastable dissolution behavior over a large area was observed for alloy 625. The ramification of the larger critical depth for Ni-Cr-Mo alloys toward crevice corrosion susceptibility in the case of crevice formers of finite length is discussed. Crevice corrosion shifts to the mouth of the crevice for the less corrosion-resistant materials in crevice solutions saturated in metal salts but remains confined at a distance x(crit) for alloy 625 under the conditions tested. (C) 2008 The Electrochemical Society.
引用
收藏
页码:C256 / C268
页数:13
相关论文
共 45 条
[1]  
Abdulsalam MI, 1999, CORROS SCI, V41, P351, DOI 10.1016/S0010-938X(98)00103-6
[2]  
*ASTM, 2003, ANNUAL BOOK ASTM STA, P343
[3]  
*ASTM, 2003, ANNUAL BOOK ASTM STA
[4]  
BOCHER F, 2006, EL SOC M CANC MEX OC
[5]  
BOCHER F, 2007, NACE M NASHV TN MARC
[6]   Coupled multielectrode investigation of crevice corrosion of AISI 316 stainless steel [J].
Bocher, Florent ;
Presuel-Moreno, Francisco ;
Budiansky, Noah D. ;
Scully, John R. .
ELECTROCHEMICAL AND SOLID STATE LETTERS, 2007, 10 (03) :C16-C20
[7]   Occluded solution chemistry control and the role of alloy sulfur on the initiation of crevice corrosion in type 304ss [J].
Brossia, CS ;
Kelly, RG .
CORROSION SCIENCE, 1998, 40 (11) :1851-1871
[8]   Influence of alloy sulfur content and bulk electrolyte composition on crevice corrosion initiation of austenitic stainless steel [J].
Brossia, CS ;
Kelly, RG .
CORROSION, 1998, 54 (02) :145-154
[9]  
BROSSIA CS, 1995, CRITICAL FACTORS LOC, V2, P201
[10]   Use of coupled multi-electrode arrays to advance the understanding of selected corrosion phenomena [J].
Budiansky, N. D. ;
Bocher, F. ;
Cong, H. ;
Hurley, M. F. ;
Scully, J. R. .
CORROSION, 2007, 63 (06) :537-554