Viral detection using an embedded piezoresistive microcantilever sensor

被引:50
作者
Gunter, RL
Delinger, WG
Manygoats, K
Kooser, A
Porter, TL [1 ]
机构
[1] No Arizona Univ, Dept Phys, Flagstaff, AZ 86011 USA
[2] No Arizona Univ, Dept Chem, Flagstaff, AZ 86011 USA
基金
美国国家科学基金会;
关键词
vaccinia; embedded; piezoresistive; microcantilever;
D O I
10.1016/S0924-4247(03)00379-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The detection of aerosol-based vaccinia virus and solution-based vaccinia virus has been studied using a new type of microsensor design. In the embedded piezoresistive microcantilever (EPM) sensor, a tiny piezoresistive microcantilever is embedded or partially embedded into an active sensing material whose volumetric response to the presence of an analyte is recorded as a strain in the cantilever, and subsequent change in the resistance of the cantilever. In one set of experiments, a composite consisting of poly(ethylene oxide), or PEO, combined with vaccinia antibody was used as the active sensing material. In aerosol exposures, this sensor produced a distinct signal owing to vaccinia virus adsorption/incorporation. In addition, experiments using a piezoresistive microcantilever in direct contact with a pure antibody layer in solution were also performed to detect vaccinia virus in solution. Again, a clear and distinct analyte signals obtained. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 17 条
[1]   A cantilever array-based artificial nose [J].
Baller, MK ;
Lang, HP ;
Fritz, J ;
Gerber, C ;
Gimzewski, JK ;
Drechsler, U ;
Rothuizen, H ;
Despont, M ;
Vettiger, P ;
Battiston, FM ;
Ramseyer, JP ;
Fornaro, P ;
Meyer, E ;
Güntherodt, HJ .
ULTRAMICROSCOPY, 2000, 82 (1-4) :1-9
[2]   Use of compatible polymer blends to fabricate arrays of carbon black-polymer composite vapor detectors [J].
Doleman, BJ ;
Sanner, RD ;
Severin, EJ ;
Grubbs, RH ;
Lewis, NS .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2560-2564
[3]   Quantitative study of the resolving power of arrays of carbon black-polymer composites in various vapor-sensing tasks [J].
Doleman, BJ ;
Lonergan, MC ;
Severin, EJ ;
Vaid, TP ;
Lewis, NS .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4177-4190
[4]   Application of the solubility parameter concept to the design of chemiresistor arrays [J].
Eastman, MP ;
Hughes, RC ;
Yelton, G ;
Ricco, AJ ;
Patel, SV ;
Jenkins, MW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (10) :3907-3913
[5]   VOLUME PHASE-TRANSITION IN A NONIONIC GEL [J].
HIROKAWA, Y ;
TANAKA, T .
JOURNAL OF CHEMICAL PHYSICS, 1984, 81 (12) :6379-6380
[6]   Detection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors for the nerve agent simulants dimethylmethylphosphonate and diisopropylmethylphosponate [J].
Hopkins, AR ;
Lewis, NS .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :884-892
[7]   SACCHARIDE-SENSITIVE PHASE-TRANSITION OF A LECTIN-LOADED GEL [J].
KOKUFATA, E ;
ZHANG, YQ ;
TANAKA, T .
NATURE, 1991, 351 (6324) :302-304
[8]   An artificial nose based on a micromechanical cantilever array [J].
Lang, HP ;
Baller, MK ;
Berger, R ;
Gerber, C ;
Gimzewski, JK ;
Battiston, FM ;
Fornaro, P ;
Ramseyer, JP ;
Meyer, E ;
Güntherodt, HJ .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :59-65
[9]   A reversibly antigen-responsive hydrogel [J].
Miyata, T ;
Asami, N ;
Uragami, T .
NATURE, 1999, 399 (6738) :766-769
[10]   A POLYMER GEL WITH ELECTRICALLY DRIVEN MOTILITY [J].
OSADA, Y ;
OKUZAKI, H ;
HORI, H .
NATURE, 1992, 355 (6357) :242-244