IPO: a tool for automated optimization of XCMS parameters

被引:242
作者
Libiseller, Gunnar [1 ]
Dvorzak, Michaela [2 ]
Kleb, Ulrike [2 ]
Gander, Edgar [1 ]
Eisenberg, Tobias [3 ]
Madeo, Frank [3 ,4 ]
Neumann, Steffen [5 ]
Trausinger, Gert [1 ]
Sinner, Frank [1 ,6 ]
Pieber, Thomas [1 ,6 ]
Magnes, Christoph [1 ]
机构
[1] Joanneum Res Forsch Gesell mbH, Inst Biomed & Hlth Sci, Hlth, Graz, Austria
[2] Joanneum Res Forsch Gesell mbH, Inst Econ & Innovat Res, Policies, Graz, Austria
[3] Graz Univ, Inst Mol Biosci, NAWI Graz, A-8010 Graz, Austria
[4] BioTechMed Graz, A-8010 Graz, Austria
[5] Leibniz Inst Plant Biochem, Dept Stress & Dev Biol, Halle, Germany
[6] Med Univ Graz, Dept Internal Med, Graz, Austria
基金
奥地利科学基金会;
关键词
Metabolomics; XCMS; Parameter optimization; Design of experiments; Isotopologue; MASS-SPECTROMETRY DATA; METABOLOMICS; EXTRACTION; ALIGNMENT; STRATEGY; DESIGN;
D O I
10.1186/s12859-015-0562-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Untargeted metabolomics generates a huge amount of data. Software packages for automated data processing are crucial to successfully process these data. A variety of such software packages exist, but the outcome of data processing strongly depends on algorithm parameter settings. If they are not carefully chosen, suboptimal parameter settings can easily lead to biased results. Therefore, parameter settings also require optimization. Several parameter optimization approaches have already been proposed, but a software package for parameter optimization which is free of intricate experimental labeling steps, fast and widely applicable is still missing. Results: We implemented the software package IPO ('Isotopologue Parameter Optimization') which is fast and free of labeling steps, and applicable to data from different kinds of samples and data from different methods of liquid chromatography - high resolution mass spectrometry and data from different instruments. IPO optimizes XCMS peak picking parameters by using natural, stable C-13 isotopic peaks to calculate a peak picking score. Retention time correction is optimized by minimizing relative retention time differences within peak groups. Grouping parameters are optimized by maximizing the number of peak groups that show one peak from each injection of a pooled sample. The different parameter settings are achieved by design of experiments, and the resulting scores are evaluated using response surface models. IPO was tested on three different data sets, each consisting of a training set and test set. IPO resulted in an increase of reliable groups (146% - 361%), a decrease of non-reliable groups (3% - 8%) and a decrease of the retention time deviation to one third. Conclusions: IPO was successfully applied to data derived from liquid chromatography coupled to high resolution mass spectrometry from three studies with different sample types and different chromatographic methods and devices. We were also able to show the potential of IPO to increase the reliability of metabolomics data. The source code is implemented in R, tested on Linux and Windows and it is freely available for download at https://github.com/glibiseller/IPO. The training sets and test sets can be downloaded from https://health.joanneum.at/IPO.
引用
收藏
页数:10
相关论文
共 23 条
[1]   Separation and quantitation of water soluble cellular metabolites by hydrophilic interaction chromatography-tandem mass spectrometry [J].
Bajad, Sunil U. ;
Lu, Wenyun ;
Kimball, Elizabeth H. ;
Yuan, Jie ;
Peterson, Celeste ;
Rabinowitz, Joshua D. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (01) :76-88
[2]   XCMS2:: Processing tandem mass spectrometry data for metabolite identification and structural characterization [J].
Benton, H. P. ;
Wong, D. M. ;
Trauger, S. A. ;
Siuzdak, G. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6382-6389
[3]  
Box G.E.P., 1960, Technometrics, V2, P455, DOI 10.1080/00401706.1960.10489912
[4]   Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Fast and Robust Quantification of Anionic and Aromatic Metabolites [J].
Buescher, Joerg Martin ;
Moco, Sofia ;
Sauer, Uwe ;
Zamboni, Nicola .
ANALYTICAL CHEMISTRY, 2010, 82 (11) :4403-4412
[5]   A novel stable isotope labelling assisted workflow for improved untargeted LC-HRMS based metabolomics research [J].
Bueschl, Christoph ;
Kluger, Bernhard ;
Lemmens, Marc ;
Adam, Gerhard ;
Wiesenberger, Gerlinde ;
Maschietto, Valentina ;
Marocco, Adriano ;
Strauss, Joseph ;
Boedi, Stephan ;
Thallinger, Gerhard G. ;
Krska, Rudolf ;
Schuhmacher, Rainer .
METABOLOMICS, 2014, 10 (04) :754-769
[6]   MetExtract: a new software tool for the automated comprehensive extraction of metabolite-derived LC/MS signals in metabolomics research [J].
Bueschl, Christoph ;
Kluger, Bernhard ;
Berthiller, Franz ;
Lirk, Gerald ;
Winkler, Stephan ;
Krska, Rudolf ;
Schuhmacher, Rainer .
BIOINFORMATICS, 2012, 28 (05) :736-738
[7]   Strategy for Optimizing LC-MS Data Processing in Metabolomics: A Design of Experiments Approach [J].
Eliasson, Mattias ;
Rannar, Stefan ;
Madsen, Rasmus ;
Donten, Magdalena A. ;
Marsden-Edwards, Emma ;
Moritz, Thomas ;
Shockcor, John P. ;
Johansson, Erik ;
Trygg, Johan .
ANALYTICAL CHEMISTRY, 2012, 84 (15) :6869-6876
[8]   A comprehensive method for lipid profiling by liquid chromatography-ion cyclotron resonance mass spectrometry [J].
Fauland, Alexander ;
Koefeler, Harald ;
Troetzmueller, Martin ;
Knopf, Astrid ;
Hartler, Juergen ;
Eberl, Anita ;
Chitraju, Chandramohan ;
Lankmayr, Ernst ;
Spener, Friedrich .
JOURNAL OF LIPID RESEARCH, 2011, 52 (12) :2314-2322
[9]   Processing methods for differential analysis of LC/MS profile data [J].
Katajamaa, M ;
Oresic, M .
BMC BIOINFORMATICS, 2005, 6 (1)
[10]   CAMERA: An Integrated Strategy for Compound Spectra Extraction and Annotation of Liquid Chromatography/Mass Spectrometry Data Sets [J].
Kuhl, Carsten ;
Tautenhahn, Ralf ;
Boettcher, Christoph ;
Larson, Tony R. ;
Neumann, Steffen .
ANALYTICAL CHEMISTRY, 2012, 84 (01) :283-289