Stator Interturn Fault Detection in Permanent-Magnet Machines Using PWM Ripple Current Measurement

被引:50
作者
Sen, Bhaskar [1 ]
Wang, Jiabin [1 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Elect Machines & Drives Res Grp, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Condition monitoring; fault diagnosis; fault location; permanent-magnet (PM) machines; pulsewidth modulation (PWM) inverters; switching frequency fault detection; MOTOR; DIAGNOSIS; HYBRID; DRIVES;
D O I
10.1109/TIE.2016.2515560
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a novel method of interturn fault detection based on measurement of pulsewidth modulation (PWM) ripple current. The method uses the ripple current generated by the switching inverter as a means to detect interturn fault. High-frequency (HF) impedance behavior of healthy and faulted windings is analyzed and modeled, and ripple current signature due to interturn faults is quantified. A simple analog circuit is designed to extract the PWM ripple current via a bandpass (BP) filter and a root-mean-square (RMS) detector for fault detection. In addition, this method can also identify the faulted phase, which can be used for fault mitigation strategies. The method is tested experimentally on a five-phase permanent-magnet (PM) machine drive.
引用
收藏
页码:3148 / 3157
页数:10
相关论文
共 31 条
[1]  
[Anonymous], 2014, P 7 IET INT C POW EL, DOI DOI 10.1049/IET-TV.50.19186
[2]  
[Anonymous], 1982, EL4286V1 EL POW RES
[3]  
[Anonymous], 1985, IEEE T IND APPL
[4]  
[Anonymous], 1985, IEEE T IND APPL
[5]   Winding condition monitoring scheme for a permanent magnet machine using high-frequency injection [J].
Arellano-Padilla, J. ;
Sumner, M. ;
Gerada, C. .
IET ELECTRIC POWER APPLICATIONS, 2011, 5 (01) :89-99
[6]  
Bianchini C, 2008, IEEE IND ELEC, P1147
[7]   Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM [J].
Boileau, Thierry ;
Leboeuf, Nicolas ;
Nahid-Mobarakeh, Babak ;
Meibody-Tabar, Farid .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (12) :5647-5654
[8]   CAUSE AND ANALYSIS OF STATOR AND ROTOR FAILURES IN 3-PHASE SQUIRREL-CAGE INDUCTION-MOTORS [J].
BONNETT, AH ;
SOUKUP, GC .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (04) :921-937
[9]  
Bonnett AH, 2008, IEEE IND APPL MAG, V14, P29, DOI 10.1109/MIA.2007.909802
[10]   Online stator winding fault diagnosis in inverter-fed AC machines using high-frequency signal injection [J].
Briz, F ;
Degner, MW ;
Zamarrón, A ;
Guerrero, JM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (04) :1109-1117