A free-air ionization chamber with a large aperture diaphragm

被引:1
|
作者
Takata, N. [1 ]
机构
[1] AIST, NMIJ, Ionizing Radiat Sect, Tsukuba, Ibaraki 3058568, Japan
关键词
Parallel-plate free-air ionization chamber; Ionization volume; Charge collection volume; Electric field distortion; Guard electrode; Scattered X-rays; Air kerma; Exposure; X-RAYS;
D O I
10.1016/j.nima.2010.02.083
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Calculations of the electric field distributions in free-air ionization chambers reveal that the distortion of the charge collection volume is small even for wide X-ray beam passage if the diaphragm and the X-ray shielding box are kept at a potential equal to half that applied to the high-voltage electrode. Applying this potential to the diaphragm and the shielding box permits a larger aperture diaphragm to be used. This will allow a wider X-ray beam to enter the chamber, thus generating a larger signal. In addition, the distance between the diaphragm and the charge collection volume can be shortened to reduce the amount of X-ray attenuation. It is also possible to calibrate a dosimeter against a free-air ionization chamber that has a diaphragm whose aperture size is equal to the size of the dosimeter in an X-ray field that is collimated to the same size. This is important since free-air ionization chambers are not sensitive to X-rays that are incident at large angles, such as those scattered by the collimator, filters and air. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 220
页数:5
相关论文
共 30 条
  • [1] PTRAC File Utilization for Calculation of Free-Air Ionization Chamber Correction Factors by MCNPX
    Solc, Jaroslav
    Sochor, Vladimir
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [2] Design and preliminary test of a free-air ionization chamber for low-energy X-ray
    Wu Jin-Jie
    Yang Yuan-Di
    Wang Pei-Wei
    Chen Jing
    Liu Jia-Cheng
    CHINESE PHYSICS C, 2011, 35 (06) : 576 - 579
  • [3] Design and preliminary test of a free-air ionization chamber for low-energy X-ray
    吴金杰
    杨元第
    王培玮
    陈靖
    柳加成
    中国物理C, 2011, (06) : 576 - 579
  • [4] Attix free-air chamber correction factors computed using EGSnrc
    Stasko, John T.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2025, : 1991 - 1996
  • [5] The performance of the INER improved free-air ionization chamber in the comparison of air kerma calibration coefficients for medium-energy X-rays
    Lee, JH
    Kotler, LH
    Büermann, L
    Hwang, WS
    Chiu, JH
    Wang, CF
    RADIATION MEASUREMENTS, 2005, 39 (01) : 1 - 10
  • [6] Novel approach for the Monte Carlo calculation of free-air chamber correction factors
    Mainegra-Hing, Ernesto
    Reynaert, Nick
    Kawrakow, Iwan
    MEDICAL PHYSICS, 2008, 35 (08) : 3650 - 3660
  • [7] Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber
    Yu Jili
    Wu Jinjie
    Liao Zhenyu
    Zhou Zhenjie
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 73 (10) : 1466 - 1472
  • [8] Experimental Measurement and Monte Carlo Simulation the Correction Factor for the Medium-Energy X-ray Free-air Ionization Chamber
    Jili Yu
    Jinjie Wu
    Zhenyu Liao
    Zhenjie Zhou
    Journal of the Korean Physical Society, 2018, 73 : 1466 - 1472
  • [9] Measurements of Air-kerma in Mammography X-Ray Standard Using Free-air Chamber
    GUO Siming
    WU Jinjie
    LIU Ying
    Instrumentation, 2017, 4 (02) : 9 - 15
  • [10] Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer
    Crosbie, Jeffrey C.
    Rogers, Peter A. W.
    Stevenson, Andrew W.
    Hall, Christopher J.
    Lye, Jessica E.
    Nordstrom, Terese
    Midgley, Stewart M.
    Lewis, Robert A.
    MEDICAL PHYSICS, 2013, 40 (06)