Two techniques to sample non-volatiles in breath-exemplified by methadone

被引:22
作者
Ljungkvist, Goran [1 ]
Ullah, Shahid [2 ,3 ]
Tinglev, Asa [2 ,3 ]
Stein, Karina [4 ]
Bake, Bjorn [5 ]
Larsson, Per [1 ]
Almstrand, Ann-Charlotte [1 ]
Viklund, Emilia [1 ]
Hammar, Oscar [6 ]
Sandqvist, Soren [2 ,3 ]
Beck, Olof [2 ,3 ]
Olin, Anna-Carin [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Dept Publ Hlth & Community Med, Gothenburg, Sweden
[2] Karolinska Inst, Dept Lab Med, Stockholm, Sweden
[3] Karolinska Univ Lab, Dept Clin Pharmacol, Stockholm, Sweden
[4] Lund Univ, Dept Clin Sci Lund, Clin Addict Res Unit, Lund, Sweden
[5] Univ Gothenburg, Sahlgrenska Acad, Inst Med, Resp Med & Allergy,Dept Internal Med, Gothenburg, Sweden
[6] AstraZeneca R&D, Molndal, Sweden
关键词
exhaled breath; endogenous particles; particle collection; exogenous compounds; EXHALED ENDOGENOUS PARTICLES; MASS-SPECTROMETRY; CONDENSATE; BIOMARKERS; SALIVA;
D O I
10.1088/1752-7163/aa8b25
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The particles in exhaled breath provide a promising matrix for the monitoring of pathological processes in the airways, and also allow exposure to exogenous compounds to be to assessed. The collection is easy to perform and is non-invasive. The aim of the present study is to assess if an exogenous compound-methadone-is distributed in the lining fluid of small airways, and to compare two methods for collecting methadone in particles in exhaled breath. Exhaled particles were collected from 13 subjects receiving methadone maintenance treatment. Two different sampling methods were applied: one based on electret filtration, potentially collecting exhaled particles of all sizes, and one based on impaction, collecting particles in the size range of 0.5-7 mu m, known to reflect the respiratory tract lining fluid from the small airways. The collected samples were analyzed by liquid chromatography mass spectrometry, and the impact of different breathing patterns was also investigated. The potential contribution from the oral cavity was investigated by rinsing the mouth with a codeine solution, followed by codeine analysis of the collected exhaled particles by both sampling methods. The results showed that methadone was present in all samples using both methods, but when using the method based on impaction, the concentration of methadone in exhaled breath was less than 1% of the concentration collected by the method based on filtration. Optimizing the breathing pattern to retrieve particles from small airways did not increase the amount of exhaled methadone collected by the filtration method. The contamination from codeine present in the oral cavity was only detected in samples collected by the impaction method. We conclude that methadone is distributed in the respiratory tract lining fluid of small airways. The samples collected by the filtration method most likely contained a contribution from the upper airways/oral fluid in contrast to the impaction method.
引用
收藏
页数:9
相关论文
共 38 条
  • [1] Exhaled breath condensate: a comprehensive update
    Ahmadzai, Hasib
    Huang, Shuying
    Hettiarachchi, Ravin
    Lin, Jiun-Lih
    Thomas, Paul S.
    Zhang, Qi
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (07) : 1343 - 1361
  • [2] TOF-SIMS analysis of exhaled particles from patients with asthma and healthy controls
    Almstrand, A-C.
    Josefson, M.
    Bredberg, A.
    Lausmaa, J.
    Sjoevall, P.
    Larsson, P.
    Olin, A-C.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2012, 39 (01) : 59 - 66
  • [3] Effect of airway opening on production of exhaled particles
    Almstrand, Ann-Charlotte
    Bake, Bjorn
    Ljungstrom, Evert
    Larsson, Per
    Bredberg, Anna
    Mirgorodskaya, Ekaterina
    Olin, Anna-Carin
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (03) : 584 - 588
  • [4] Airway Monitoring by Collection and Mass Spectrometric Analysis of Exhaled Particles
    Almstrand, Ann-Charlotte
    Ljungstrom, Evert
    Lausmaa, Jukka
    Bake, Bjorn
    Sjovall, Peter
    Olin, Anna-Carin
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (02) : 662 - 668
  • [5] A Review of Analytical Techniques and Their Application in Disease Diagnosis in Breathomics and Salivaomics Research
    Beale, David J.
    Jones, Oliver A. H.
    Karpe, Avinash V.
    Dayalan, Saravanan
    Oh, Ding Yuan
    Kouremenos, Konstantinos A.
    Ahmed, Warish
    Palombo, Enzo A.
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2017, 18 (01):
  • [6] Potential of Mass Spectrometry in Developing Clinical Laboratory Biomarkers of Nonvolatiles in Exhaled Breath
    Beck, Olof
    Olin, Anna-Carin
    Mirgorodskaya, Ekaterina
    [J]. CLINICAL CHEMISTRY, 2016, 62 (01) : 84 - 91
  • [7] Detection of drugs of abuse in exhaled breath using a device for rapid collection: comparison with plasma, urine and self-reporting in 47 drug users
    Beck, Olof
    Stephanson, Niclas
    Sandqvist, Soren
    Franck, Johan
    [J]. JOURNAL OF BREATH RESEARCH, 2013, 7 (02)
  • [8] Demonstration that methadone is being present in the exhaled breath aerosol fraction
    Beck, Olof
    Sandqvist, Soren
    Franck, Johan
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) : 1024 - 1028
  • [9] Method for determination of methadone in exhaled breath collected from subjects undergoing methadone maintenance treatment
    Beck, Olof
    Sandqvist, Soeren
    Eriksen, Paul
    Franck, Johan
    Palmskog, Goeran
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (24): : 2255 - 2259
  • [10] Exhaled breath condensate-site and mechanisms of formation
    Bondesson, Eva
    Jansson, Lennart T.
    Bengtsson, Thomas
    Wollmer, Per
    [J]. JOURNAL OF BREATH RESEARCH, 2009, 3 (01)