A dual-signal sensing strategy based on ratiometric fluorescence and colorimetry for determination of Cu2+ and glyphosate

被引:31
|
作者
Yang, Yixia [1 ]
Li, Li [1 ]
Lin, Liyun [2 ]
Wang, Xianfeng [1 ]
Li, Jiawei [1 ]
Liu, Huan [1 ,3 ]
Liu, Xiaofang [1 ]
Huo, Danqun [1 ]
Hou, Changjun [1 ,4 ]
机构
[1] Chongqing Univ, Key Lab Biorheol Sci & Technol, State & Local Joint Engn Lab Vasc Implants, Minist Educ,Bioengn Coll, Chongqing 400044, Peoples R China
[2] Chinese Acad Trop Agr Sci, Agr Prod Proc Res Inst, Zhanjiang 524001, Guangdong, Peoples R China
[3] Chongqing Inst Food & Drug Control, Chongqing 401121, Peoples R China
[4] Chongqing Univ, Sch Microelect & Commun Engn, Chongqing Key Lab Biopercept & Intelligent Inform, Chongqing 400044, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Ratiometric fluorescence; Colorimetric detection; Silicon nanoparticles; Organophosphorus pesticides; o-Phenylenediamine oxidation; SILICON QUANTUM DOTS; ONE-STEP SYNTHESIS; SENSITIVE FLUORESCENCE; AQUEOUS-SOLUTION; CARBON DOTS; NANOPARTICLES; ASSAY; OXIDATION; SENSOR; INHIBITION;
D O I
10.1007/s00216-022-03898-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, a dual-signal sensing strategy based on ratiometric fluorescence and colorimetry for Cu2+ and glyphosate determination was constructed. Fluorescence silicon nanoparticles (SiNPs) were prepared by hydrothermal reaction, which has maximum fluorescence intensity under the excitation of 355 nm. o-Phenylenediamine (OPD) was oxidized through Cu2+ to generate 2,3-diaminophenazine (oxOPD). The obtained oxOPD showed a strong absorption peak at 417 nm and quenched the fluorescence of SiNPs at 446 nm due to fluorescence resonance energy transfer (FRET). Meanwhile, oxOPD produced a new fluorescence emission at 556 nm forming a ratiometric state. With increasing Cu2+, the original solution changed from colorless to yellow. When glyphosate was present, the interaction between Cu2+ and the functional groups of glyphosate could reduce the oxidation of oxOPD, resulting in the enhancement of fluorescence at 446 nm and the decrease of fluorescence at 556 nm. Furthermore, the addition of glyphosate changed yellow solution to colorless. Under the optimal conditions of OPD (1 mM), 20 mM Tris-HCl buffer (pH 7.5), and incubation time (4 h), the ratiometric fluorescence sensor had good selectivity and showed a wide linear range of 0.025-20 mu M with the LOD of 0.008 mu M for Cu2+ and 0.15-1.5 mu g/mL with the LOD of 0.003 mu g/mL for glyphosate, respectively. Besides, it is worth mentioning that this developed sensing system showed good performance in real samples, providing a simple and reliable dual-signal detection strategy.
引用
收藏
页码:2619 / 2628
页数:10
相关论文
共 50 条
  • [21] A dual-functional probe for sensing pH change and ratiometric detection of Cu2+
    Wang, Jiang-Xu
    Xing, Zhi-Yong
    Tian, Zhen-Nan
    Wu, Ding-Qi
    Xiang, Yuan-Yuan
    Li, Jin-Long
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 235
  • [22] Carbon dots based multicolor fluorescence sensor for ratiometric and colorimetric dual-model detection of Cu2+
    Huang, Gengli
    Luo, Xueli
    Lin, Wanmei
    Tang, Wenzhi
    Yue, Tianli
    Wang, Jianlong
    Li, Zhonghong
    DYES AND PIGMENTS, 2022, 203
  • [23] Fluorescence-Scattering Dual-Signal Response of Carbon Dots@ZIF-90 for Phosphate Ratiometric Detection
    Wu, Zhihao
    Yang, Huan
    Pan, Shuang
    Liu, Hui
    Hu, Xiaoli
    ACS SENSORS, 2020, 5 (07): : 2211 - 2220
  • [24] Facile fabrication of dual-ratiometric electrochemical sensors based on a bare electrode for dual-signal sensing of analytes in electrolyte solution
    Zhao, Chunqin
    Jin, Hui
    Gui, Rijun
    Wang, Zonghua
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 242 : 71 - 78
  • [25] Novel ratiometric fluorescence and colorimetric dual-mode biosensors for Cu2+ and biothiols detection based on norepinephrine modified carbon dots
    Chen, Xiaoping
    Zhuang, Yafeng
    Chen, Jing
    Lin, Jianwei
    Chen, Jinghua
    Han, Zhizhong
    MICROCHEMICAL JOURNAL, 2022, 181
  • [26] Hydrophobic-carbon-dot-based dual-emission micelle for ratiometric fluorescence biosensing and imaging of Cu2+ in liver cells
    Lu, Linlin
    Feng, Chongchong
    Xu, Jie
    Wang, Fengyang
    Yu, Haijun
    Xu, Zhiai
    Zhang, Wen
    BIOSENSORS & BIOELECTRONICS, 2017, 92 : 101 - 108
  • [27] A ratiometric fluorescent and colorimetric dual-signal sensing platform based on N-doped carbon dots for selective and sensitive detection of copper (II) and pyrophosphate ion
    Zhang, Wen Jie
    Liu, Shi Gang
    Han, Lei
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 215 - 221
  • [28] A ratiometric fluorescence and colorimetric dual-mode sensing platform based on sulfur quantum dots and carbon quantum dots for selective detection of Cu2+
    Hanqiang Zhang
    Yufei Li
    Haixin Lu
    Feng Gan
    Analytical and Bioanalytical Chemistry, 2022, 414 : 2471 - 2480
  • [29] A dual-emission ratiometric fluorescence strategy with enzyme-based inhibition for organophosphorus pesticides determination
    Xu, Feifei
    Li, Xinyang
    Chen, Chen
    Liang, Zhigang
    Xu, Guanhong
    Wei, Fangdi
    Yang, Jing
    Hu, Qin
    Cen, Yao
    MICROCHIMICA ACTA, 2023, 190 (08)
  • [30] A dual-emission ratiometric fluorescence strategy with enzyme-based inhibition for organophosphorus pesticides determination
    Feifei Xu
    Xinyang Li
    Chen Chen
    Zhigang Liang
    Guanhong Xu
    Fangdi Wei
    Jing Yang
    Qin Hu
    Yao Cen
    Microchimica Acta, 2023, 190